Search results for "Electrode"
showing 10 items of 950 documents
DOUBLE EARTH FAULT EFFECTS IN PRESENCE OF INTERCONNECTED EARTH ELECTRODES
2009
The paper presents a study on the effects of double earth faults in Medium Voltage (MV) networks, in presence of electrical interconnection of the earthing systems of the secondary substations. In urban areas, indeed, the earth electrodes of the secondary substations are interconnected and, in many cases, they are also connected to the earth electrodes of the primary stations, in order to realize quasi-equipotential surfaces, intrinsically safe against electric shocks, named Global Earthing Systems (GES). The concept of GES has been introduced in the technical literature ten years ago in the Document HD 637 S1 by CENELEC, with the aim of providing a solution to the problems of designing and…
The Quest for Global Safety
2007
The authors present a systematic study on the factors that have influence on the establishment of the safety conditions ensuring the rise of Global Earthing Systems. Starting from the definition of Global Earthing System given by CENELEC Document HD 637 SI and from the results of the studies done on the last years on the interconnected earthing systems inside MV networks, the paper proposes some directions of deepening on the topic of Global Safety. Some of the themes whom the paper deals with are: the correct definition of proximity, interconnection and quasi-equipotentiality of the earth electrodes belonging to a Global Earthing System; the influence of the presence of HV/MV stations on h…
Ground-Fault Current Transfer at the Transition Station of a Combined Overhead-Cable Line. A Parametric Analysis
2007
When a substation is fed by a combined overhead-cable transmission line, a significant part of the ground fault current flows through the grounded cable sheaths and discharges into the earth at the transition station, where cables are connected to the overhead line. If the transition station is a dead-end steel pole structure, the local ground electrode, small and of high resistance, could be inadequate to maintain the ground potential rise within safety limits in case of a fault to ground at the receiving end substation. Based on a circuit model approach, the paper presents a parametric analysis of the fault current distribution between the faulted substation and the transition station, ta…
Reverse electrodialysis performed at pilot plant scale: Evaluation of redox processes and simultaneous generation of electric energy and treatment of…
2017
Abstract This paper describes the experimental campaign carried out with a reverse electrodialysis (RED) demonstration plant (Marsala, Italy) with the main aims of: (i) evaluating the effect of various operating parameters, including the redox processes, on the system performances; (ii) using the plant for the simultaneous generation of electric energy and treatment of wastewater. The prototype (44 × 44 cm2, 500 cell pairs) was tested using both real (brackish water and brine) and artificial solutions. Tests with two different electrode rinse solutions (with or without iron redox couples) were performed. In agreement with the data obtained in the laboratory, the presence of iron ions contri…
Study of the chlorfenvinphos pesticide removal under different anodic materials and different reactor configuration.
2021
The present manuscript focuses on the study of the electrochemical oxidation of the insecticide Chlorfenvinphos (CVP). The assays were carried out under galvanostatic conditions using boron-doped diamond (BDD) and low-cost tin dioxide doped with antimony (Sb-doped SnO2) as anodes. The influence of the operating variables, such as applied current density, presence or absence of a cation-exchange membrane and concentration of supporting electrolyte, was discussed. The results revealed that the higher applied current density the higher degradation and mineralization of the insecticide for both anodes. The presence of the membrane and the highest concentration of Na2SO4 studied (0.1 M) as a sup…
Protecting emergency workers and armed forces from volatile toxic compounds: Applicability of reversible conductive polymer-based sensors in barrier …
2019
International audience; Barrier materials have wide applicability in both professional (military, medical, industrial) and non-professional(leisure and sports) fields. This paper focuses on the preparation of real conductive polymer (CP) sensors, for thestudy of the permeation of volatile toxic compounds through barrier materials. Use of such a CP sensor can helpimprove the quality of barrier materials used in protective clothing. Several types of platforms have beenmanufactured or purchased for use as comb sensors with different electrode dimensions, and a suitable methodof applying the detection layer of conductive polymers (polyaniline and poly-pyrrole) has been developed. Prepared senso…
Comparative electrochemical treatments of two chlorinated aliphatic hydrocarbons. Time course of the main reaction by-products.
2011
The chlorinated aliphatic hydrocarbons conjugate toxicity with high chemical stability, bioaccumulation and long-range diffusivity. Chloroethanes are particularly ubiquitous in the industry and in household products, and their entry to the environment may entail potential risks for the living beings. At present, the US Environmental Protection Agency is carrying out the Endocrine Disruptor Screening Program (EDSP), where 1,2-dichloroethane (DCA) and 1,1,2,2-tetrachloroethane (TCA) are considered as priorities for their potential effects on the endocrine system. DCA is also found in the list of priority substances drawn up by the European Commission. To avoid the release of chloroethanes int…
New epicardial mapping electrode with warming/cooling function for experimental electrophysiology studies
2010
Cardiac electrical activity is influenced by temperature. In experimental models, the induction of hypothermia and/or hyperthermia has been used for the study of mechanisms of cardiac arrhythmia. A system that allows for localized, controlled induction, besides simultaneously recording electrical activity in the same induced area, needs to be developed ad hoc. This article describes the construction and application of a new system capable of locally modifying the epicardial temperature of isolated hearts and of carrying out cardiac mapping with sufficient spatial resolution. The system is based on a thermoelectric refrigerator and an array of 128 stainless steel unipolar electrodes in encap…
Pacemaker therapy in premature children with high degree AV block.
1998
The smallest pacemaker pulse generator and a steroid-eluting bipolar epicardial lead were implanted in two premature children with symptomatic AV block. Stable capture threshold and high amplitude evoked response electrogram resulted in normal function of the pacemaker Autocapture algorithm, which adjusts output 0.3 V above the measured capture threshold. Autocapture had previously been used only with endocardial leads. Longer-term observation is required.
Scalp, basal epidural and intravascular far-field recordings after median nerve stimulation: evidence for a separate N18a potential
2000
Far-field somatosensory evoked potentials (SSEPs) after median nerve stimulation were recorded from scalp- (Fz), epidural- (ED) and intravascular electrodes (basilar artery [Bas]) to study the nature of the controversial N18a component of the widespread N18 potential. In healthy volunteers frequently an N18a potential was recorded at Fz. Simultaneous Fz and ED recordings at the pontomesencephalic junction as well as Bas-recordings at the caudal basilar artery showed N18a components identical in latency and shape. With intravascular recordings the shapes differed between the top of the basilar artery and the caudal artery recordings. These findings support the existence of a separate N18a po…