Search results for "Electrodes"
showing 10 items of 231 documents
Review of space charge measurement systems: acoustic, thermal and optical methods
2016
In the last decade, remarkable developments have concerned the methods of space charge measurement in the field of insulation systems diagnostic. In particular, methods based on acoustic and thermal phenomena have been largely used. The present review provides a broad overview on the different techniques used describing, for each of them, the working principle, the main features and the most relevant applications. Further details are provided for the Pulsed Electro-Acoustic (PEA) method, as it seems to be the most used. This article provides more details on its historical evolution, showing evidence for its technological limits and taking into consideration the advantages and drawn from the…
Temporal-spatial characteristics of phase-amplitude coupling in electrocorticogram for human temporal lobe epilepsy.
2017
Objective Neural activity of the epileptic human brain contains low- and high-frequency oscillations in different frequency bands, some of which have been used as reliable biomarkers of the epileptogenic brain areas. However, the relationship between the low- and high-frequency oscillations in different cortical areas during the period from pre-seizure to post-seizure has not been completely clarified. Methods We recorded electrocorticogram data from the temporal lobe and hippocampus of seven patients with temporal lobe epilepsy. The modulation index based on the Kullback-Leibler distance and the phase-amplitude coupling co-modulogram were adopted to quantify the coupling strength between t…
Electroporation by concentric-type needle electrodes and arrays.
2017
Abstract The efficacy of genomic medicine depends on gene transfer efficiency. In this area, electroporation has been found to be a highly promising method for physical gene transfer. However, electroporation raises issues related to electrical safety, tissue damage, and the number of required wounds. Concentric-type needle electrodes seek to address these issues by using a lower bias (10 V), a single wound, fewer processing steps, and a smaller working area (≈ 10 mm 3 ), thus offering greater accuracy and precision. Moreover, the needle can be arrayed to simultaneously treat several target regions. This paper proposes a novel method using concentric-type needle electrodes to improve the ef…
Network effects and pathways in Deep brain stimulation in Parkinson's disease.
2016
Deep brain stimulation of subthalamic nucleus (STN-DBS) became a standard therapeutic option in Parkinson's disease (PD), even though the underlying modulated network of STN-DBS is still poorly described. Probabilistic tractography and connectivity analysis as derived from diffusion tensor imaging (DTI) were performed together with modelling of implanted electrode positions and linked postoperative clinical outcome. Fifteen patients with idiopathic PD without dementia were selected for DBS treatment. After pre-processing, probabilistic tractography was run from cortical and subcortical seeds of the hypothesized network to targets represented by the positions of the active DBS contacts. The …
Selection of the Optimal Algorithm for Real-Time Estimation of Beta Band Power during DBS Surgeries in Patients with Parkinson's Disease
2017
Deep Brain Stimulation (DBS) is a surgical procedure for the treatment of motor disorders in patients with Parkinson’s Disease (PD). DBS involves the application of controlled electrical stimuli to a given brain structure. The implantation of the electrodes for DBS is performed by a minimally invasive stereotactic surgery where neuroimaging and microelectrode recordings (MER) are used to locate the target brain structure. The Subthalamic Nucleus (STN) is often chosen for the implantation of stimulation electrodes in DBS therapy. During the surgery, an intraoperative validation is performed to locate the dorsolateral region of STN. Patients with PD reveal a high power in the β band (frequenc…
Imaging biomarkers of behavioral impairments: A pilot micro-positron emission tomographic study in a rat electrical post-status epilepticus model.
2018
Objective In patients with epilepsy, psychiatric comorbidities can significantly affect the disease course and quality of life. Detecting and recognizing these comorbidities is central in determining an optimal treatment plan. One promising tool in detecting biomarkers for psychiatric comorbidities in epilepsy is positron emission tomography (PET). Methods Results Behavioral and biochemical variables were cross-correlated with the results from two mu PET scans using the tracers [F-18]fluoro-2-deoxy-D-glucose ([F-18]FDG) and 2 '-methoxyphenyl-(N-2 '-pyridinyl)-p-F-18-fluoro-benzamidoethylpiperazine ([F-18]MPPF) to explore potential biomarkers for neurobehavioral comorbidities in an electrica…
The quality of cortical network function recovery depends on localization and degree of axonal demyelination
2016
AbstractMyelin loss is a severe pathological hallmark common to a number of neurodegenerative diseases, including multiple sclerosis (MS). Demyelination in the central nervous system appears in the form of lesions affecting both white and gray matter structures. The functional consequences of demyelination on neuronal network and brain function are not well understood. Current therapeutic strategies for ameliorating the course of such diseases usually focus on promoting remyelination, but the effectiveness of these approaches strongly depends on the timing in relation to the disease state. In this study, we sought to characterize the time course of sensory and behavioral alterations induced…
Analyzing the feasibility of time correlated spectral entropy for the assessment of neuronal synchrony
2016
In this paper, we study neuronal network analysis based on microelectrode measurements. We search for potential relations between time correlated changes in spectral distributions and synchrony for neuronal network activity. Spectral distribution is quantified by spectral entropy as a measure of uniformity/complexity and this measure is calculated as a function of time for the recorded neuronal signals, i.e., time variant spectral entropy. Time variant correlations in the spectral distributions between different parts of a neuronal network, i.e., of concurrent measurements via different microelectrodes, are calculated to express the relation with a single scalar. We demonstrate these relati…
Toward evidence-based severity assessment in rat models with repeated seizures: I. Electrical kindling
2018
Objective: Rodent epilepsy models can significantly contribute to our understanding of pathophysiological mechanisms and to validation of biomarker and target candidates. Evidence-based severity assessment is a presupposition for the ethical evaluation of animal experimentation allowances as well as for the development of efficacious refinement concepts. Methods: Aiming to improve our understanding of the impact of experimental procedures and repeated seizures, we have completed a comprehensive behavioral and biochemical analysis assessing various parameters that can inform about the influence of an electrical kindling paradigm on well-being in rats. Thereby, we have focused on the immediat…
The Importance of Developing Electrochemical Sensors Based on Molecularly Imprinted Polymers for a Rapid Detection of Antioxidants
2021
International audience; This review aims to pin out the importance of developing a technique for rapid detection of antioxidants, based on molecular imprinting techniques. It covers three major areas that have made great progress over the years in the field of research, namely: antioxidants characterization, molecular imprinting and electrochemistry, alone or combined. It also reveals the importance of bringing these three areas together for a good evaluation of antioxidants in a simple or complex medium, based on selectivity and specificity. Although numerous studies have associated antioxidants with molecular imprinting, or antioxidants with electrochemistry, but even electrochemistry wit…