Search results for "Electromagnetic shielding"
showing 9 items of 79 documents
EP-1590: Shielding design and fetal dose evaluation of a breast cancer pregnant patient undergoing HDR Ir-192 brachytherapy
2015
1H and 13C shielding measurements in comparison with DFT calculations performed for two 2-(acetyloamino)-N,N-dimethyl-3-phenylacrylamide isomers
2015
Abstract We present measurements of 1H and 13C shielding for (2E)- and (2Z)-2-(acetyloamino)-N,N-dimethyl-3-phenylacrylamide isomers in solutions. Practically the same values of the shielding were obtained using internal and external referencing. For the interpretation, we explore DFT calculations of shieldings performed at the rovibrationally averaged geometries. The comparison of the experimental and theoretical results is verified both for the shielding and chemical shift. It appears that some inaccuracies in the calculations of the chemical shift can be reduced due to the error compensation while subtracting the reference shielding. As shown the measurement of magnetic shielding can be …
Status of ITER TBM port plug conceptual design and analyses
2014
The test blanket module port plug (TBM PP) consists of a TBM frame and two TBM-sets. However, at any time of the ITER operation, a TBM set can be replaced by a dummy TBM. The frame provides a standardized interface with the vacuum vessel (VV)/port structure and provides thermal isolation from the shield blanket. As one of the plasma-facing components, it shall withstand heat loads while at the same time provide adequate neutron shielding for the VV and magnet coils. The frame design shall provide a stable engineering solution to hold TBM-sets and also provide a mean for rapid remote handling replacement and refurbishment. This paper presents main design features of the conceptual design of …
Analysis of EMI Shielding Effectiveness for plastic fiber composites in the 5G sub-6 GHz band
2021
The study and modeling of EMC are becoming more critical than ever due to the ubiquitous presence of electronic circuits in all aspects of our lives. Specifically, it is crucial to extend these studies to the new frequencies that, in a few years, will be a reality in modern telecommunications systems, such as 5G and its derived technologies. A specific critical field where the proper EMI shielding has been ensured to avoid EMC problems is the electric autonomous vehicles (EAVs). The huge number of electronics systems in new vehicles will dramatically extend the demands on the EMI shielding solutions used to attenuate the radiated emissions that could affect circuits in the vehicle. Metals o…
Coil overlap in moderately concentrated polyelectrolyte solutions: effects of self-shielding as compared with salt-shielding as a function of chain l…
2016
The generalized intrinsic viscosity {η} (hydrodynamic volume of the solute at arbitrary polymer concentration c) – introduced by analogy to the intrinsic viscosity [η] – provides access to the degree of coil overlap Ω for polyelectrolyte solutions in pure water or in saline water. The experimental basis of this investigation consists in viscosity measurements as a function of c for a large number of sodium polystyrene sulfonate (Na-PSS) samples covering the molecular weight range from 0.91 to 1000 kg mol−1. The accurate modeling of these dependencies with a maximum of three parameters yields detailed information on Ω as a function of (c[η]) in the absence and in the presence of extra salt. …
Tube Housing Leakiness Radiation and Patient Related Radiation Protective Measures – Gonads Radiation Exposure from Panoramic Radiography
2009
The purpose of this study was to compare patient- and apparatus related radiation protective measures considering gonad radiation exposure at panoramic radiography. The local dose (yGv) in the region of the gonads of a male Alderson-Rando-Phantom was measured by the dosimeter Tol-F (Berthold Technology, Germany) during panoramic radiography (PR) by the digital Orthophos XG plus®(Sirona / Bensheim, Germany). Different radiation protective measures was investigated during constant exposure parameters. In the second part of the survey the same ionisation chamber recorded the scattered radiation at the gonads level of the none protected phantom at various case shielding. Without protection apro…
Radiation transmission data for radionuclides and materials relevant to brachytherapy facility shielding
2008
To address the limited availability of radiation shielding data for brachytherapy as well as some disparity in existing data, Monte Carlo simulation was used to generate radiation transmission data for 60Co, 137CS, 198Au, 192Ir 169Yb, 170Tm, 131Cs, 125I, and 103pd photons through concrete, stainless steel, lead, as well as lead glass and baryte concrete. Results accounting for the oblique incidence of radiation to the barrier, spectral variation with barrier thickness, and broad beam conditions in a realistic geometry are compared to corresponding data in the literature in terms of the half value layer (HVL) and tenth value layer (TVL) indices. It is also shown that radiation shielding calc…
Broad beam transmission data for the shielding of brachytherapy facilities
2008
A Monte Carlo-aided design of a modular 241Am-Be neutron irradiator
2013
Monte Carlo studies aimed at designing a modular 241Am-Be neutron irradiator for testing neutron detectors and personal dosimeters and processing large volume samples are reported in this study. The evaluation of the shapes and thicknesses of the moderator and shielding materials was carried out by a MCNP5 Monte Carlo simulation code. The reliability of the simulation was experimentally verified by the activation of gold foils and TLD dosimeter measurements in an irradiation cell placed at the center of the test configuration.