Search results for "Electron ionization"

showing 10 items of 82 documents

Electron impact ionization/dissociation of size selected gold cluster cations

2000

Abstract Singly charged gold clusters, Au n + in the size range n =12 to 72 have been captured and stored in a Penning trap, size selected and subjected to an electron beam. This interaction leads to further ionization as well as dissociation. The resulting abundance spectra of doubly and triply charged clusters show (a) a lower size limit for the production of multiply charged clusters from an ensemble of hot precursors, which can be understood in terms of the respective decay pathways, (b) an odd/even alternation of singly and doubly charged clusters in the size range below n =30, which inverses sign with change of charge state, and (c) magic numbers, i.e. prominent signals for particular…

Gold clusterRadiationChemistryCondensed Matter PhysicsPenning trapAtomic and Molecular Physics and OpticsDissociation (chemistry)Spectral lineElectronic Optical and Magnetic MaterialsIonizationCathode rayCluster (physics)Physical and Theoretical ChemistryAtomic physicsSpectroscopyElectron ionizationJournal of Electron Spectroscopy and Related Phenomena
researchProduct

The identification of autoionizing states of atomic chromium for the resonance ionization laser ion source of the ISOLDE radioactive ion beam facility

2017

Abstract This paper presents the results of an investigation into autoionizing states of atomic chromium, in the service of the resonance ionization laser ion source (RILIS): the principal ion source of the ISOLDE radioactive ion beam facility based at CERN. The multi-step resonance photo-ionization process enables element selective ionization which, in combination with mass separation, allows isotope specific selectivity in the production of radioactive ion beams at ISOLDE. The element selective nature of the process requires a multi-step “ionization scheme” to be developed for each element. Using the method of in-source resonance ionization spectroscopy, an optimal three-step, three-reson…

Ion beamChemistry010401 analytical chemistryResonanceMass spectrometryphysics.atom-ph01 natural sciencesIon sourceAtomic and Molecular Physics and Optics0104 chemical sciencesAtmospheric-pressure laser ionizationAnalytical ChemistryIon beam depositionIonization0103 physical sciencesPhysics::Atomic and Molecular ClustersPhysics::Accelerator PhysicsNuclear Physics - ExperimentPhysics::Atomic PhysicsAtomic physics010306 general physicsInstrumentationElectron ionizationSpectroscopySpectrochimica Acta Part B: Atomic Spectroscopy
researchProduct

Mass spectrometry applications

2012

The history of proteomics dates back to the discovery of two-dimensional gels in the 1970s, which provided the first feasible way of displaying hundreds or thousands of proteins on a single gel. Despite mass spectrometry being restricted for a long time to small and thermostable compounds, the development in the late 1980s of two techniques for the routine and general formation of molecular ions of intact biomolecules changed this situation and mass spectrometry has become an indispensable tool for proteomics research. The aim of this chapter is to review the major types of MS instruments used in proteomics analysis and to discuss strategies for the analysis of whole proteins and peptides o…

Ion-mobility spectrometry–mass spectrometryLiquid chromatography–mass spectrometryChemistryLife ScienceComputational biologyDirect electron ionization liquid chromatography–mass spectrometry interfaceProteomicsMass spectrometryMozzarella cheeseMass spectrometry imaging
researchProduct

Electron Ionization Induced Fragmentation of some 3-Aroylamino-5-Methyl-1,2,4- Oxadiazoles and 3-Acetylamino-5-Aryl-1,2,4-Oxadiazoles

2017

: Background and objectives. 1,2,4-Oxadiazoles show a high reactivity and represent starting compounds for the synthesis of several other heterocycles. Some their derivatives can give the so called Boulton-Katritzky Reactions (BKR) which opens the way to the synthesis of several azoles. For this reason we have registered the mass spectra of several 3-aroylamino-5-methyl-1,2,4-oxadiazoles and 3-acetylamino-5-aryl-1,2,4-oxadiazoles. Methods and results. Thus, studying the mass spectra of the isomeric couple 3-benzoylamino-5-methyl-1,2,4-oxadiazole (1A) and 3-acetylamino-5-phenyl-1,2,4-oxadiazoles (1B) we have observed that MIKE and CID MIKE spectra of their molecular ions and of the [M – CH2C…

Mass spectrometryStereochemistryArylOrganic ChemistryMass spectrometryPhotochemistrychemistry.chemical_compoundEI induced rearrangementchemistryFragmentation (mass spectrometry)Boulton-Katritzky Reactions (BKR)Fragmentation mechanism3-Acylamino-124-oxadiazolesElectron ionization
researchProduct

VUV irradiance measurement of a 2.45 GHz microwave-driven hydrogen discharge

2015

Absolute values of VUV-emission of a 2.45 GHz microwave-driven hydrogen discharge are reported. The measurements were performed with a robust and straightforward method based on a photodiode and optical filters. It was found that the volumetric photon emission rate in the VUV-range (80-250 nm) is $10^{16}$-$10^{17}$ 1/cm$^3$s, which corresponds to approximately 8% dissipation of injected microwave power by VUV photon emission. The volumetric emission of characteristic emission bands was utilized to diagnostics of molecular plasma processes including volumetric rates of ionization, dissociation and excitation to high vibrational levels and metastable states. The estimated reaction rates impl…

Materials scienceAcoustics and UltrasonicsHydrogenchemistry.chemical_elementFOS: Physical sciencesPlasmaCondensed Matter Physics7. Clean energyPhysics - Plasma PhysicsSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsPhotodiodelaw.inventionPlasma Physics (physics.plasm-ph)chemistrylawIonizationMetastabilityPhysics::Atomic and Molecular ClustersAtomic physicsMicrowaveElectron ionizationExcitation
researchProduct

VUV diagnostic of electron impact processes in low temperature molecular hydrogen plasma

2015

Novel methods for diagnostics of molecular hydrogen plasma processes, such as ionization, production of high vibrational levels, dissociation of molecules via excitation to singlet and triplet states and production of metastable states, are presented for molecular hydrogen plasmas in corona equilibrium. The methods are based on comparison of rate coefficients of plasma processes and optical emission spectroscopy of lowest singlet and triplet transitions, i.e. Lyman-band ($B^1\Sigma^+_u \rightarrow X^1\Sigma^+_g$) and molecular continuum ($a^3\Sigma^+_g \rightarrow b^3\Sigma^+_u$), of the hydrogen molecule in VUV wavelength range. Comparison of rate coefficients of spin-allowed and/or spin-f…

Materials scienceFOS: Physical sciencesPlasmaCondensed Matter Physics01 natural sciencesDissociation (chemistry)Physics - Plasma Physics010305 fluids & plasmasPlasma Physics (physics.plasm-ph)Electric arcPhysics::Plasma PhysicsIonizationMetastability0103 physical sciencesMoleculeSinglet stateAtomic physics010306 general physicsElectron ionization
researchProduct

Ionization potential of aluminum clusters

1998

Structure, electronic structure, and ionization potential of aluminum clusters of 2–23 atoms are studied with a total energy method based on the density-functional theory. The calculated adiabatic ionization potentials agree remarkably well with the data from threshold photoionization measurements. The analysis of results gives insight into hybridization effects in the smallest clusters as well as reveals certain clusters that exhibit a clear jellium-type shell structure. An explanation of the experimental results in the size region of 12–23 atoms is given in terms of coexisting, competing icosahedral, decahedral, and fcc-based clusters. @S0163-1829~98!00228-8#

Materials scienceIcosahedral symmetryIonizationPhysics::Atomic and Molecular ClustersThermal ionizationElectronic structurePhotoionizationIonization energyAdiabatic processMolecular physicsElectron ionization
researchProduct

Trace detection of radiotoxic isotopes by resonance ionization mass spectrometry

1995

Resonance ionization spectroscopy combined with mass spectrometry (RIMS) has become an important technique for ultratrace environmental analysis, and is particularly well suited for the detection of long-lived radio-toxic isotopes. A variety of experimental approaches have been developed to address the specific requirements posed by individual isotopes, which have widely differing physical, chemical, and environmental properties. In this paper we discuss the principles and recent progress in the development of three different methods that are being used for the analysis of radiotoxic species. These include measurement of actinides using triple-resonance ionization and time-of-flight mass sp…

Materials scienceIsotopeEnvironmental analysisIonizationRadiochemistryActinideDirect electron ionization liquid chromatography–mass spectrometry interfaceThermal ionization mass spectrometryCondensed Matter PhysicsSpectroscopyMass spectrometryMathematical PhysicsAtomic and Molecular Physics and OpticsPhysica Scripta
researchProduct

Trapping of ions from high energy sources into a radiofrequency ion trap

1982

An attempt is described to confine ions, created externally and accelerated to some energy, in an rf quadrupole trap. 4 keV Ba+ ions were stopped on a Ni foil, placed in an aperture of one trap electrode. The Ba then was evaporated from the heated foil and ionized by electron impact. At background pressure of about 10−5 mbar of various light buffer gases (He, H2, N2), the trap was filled once with 105 ions, at a minimum primary ion number of 1010. The storage time was 10 min. From the data obtained the possibility of spectroseopic experiments on rare isotopes, created with accelerators or nuclear reactors, is discussed.

Materials sciencePhysics and Astronomy (miscellaneous)General EngineeringGeneral Physics and AstronomyIonTrap (computing)Physics::Plasma PhysicsIonizationElectrodeQuadrupolePhysics::Accelerator PhysicsPhysics::Atomic PhysicsIon trapAtomic physicsElectron ionizationFOIL methodApplied Physics B Photophysics and Laser Chemistry
researchProduct

A laser ion source for trace analysis

1988

A laser ion source has been set up which is based on resonant stepwise excitation and ionization of atomic vapor confined in an ionization chamber. Using a pulsed copper vapor/dye laser system with a high repetition rate (6.5 kHz) one expects high efficiency and high selectivity for this new type of ion source. First test experiments with lead are reported.

Matrix-assisted laser desorption electrospray ionizationChemistryClinical BiochemistryAnalytical chemistryGeneral MedicineBiochemistryIon sourceAnalytical ChemistryAtmospheric-pressure laser ionizationIon beam depositionIonizationGeneral Materials SciencePhysics::Atomic PhysicsAtomic vapor laser isotope separationElectron ionizationAmbient ionizationFresenius Zeitschrift f�r Analytische Chemie
researchProduct