Search results for "Electron microscope"

showing 10 items of 784 documents

Template electrosynthesis of La(OH)3 and Nd(OH)3 nanowires using porous anodic alumina membranes

2007

High quality arrays of Ln(OH)3 (Ln = La, Nd) nanowires have been successfully fabricated for the first time by an electrochemical process using anodic alumina membrane templates. A physico-chemical characterisation of electrodeposited hydroxides has been carried out by different techniques (XRD, SEM and EDX). The results show that the synthesized nanostructures are crystalline, dense, continuous, well aligned, and with high aspect ratio, suggesting further development of possible applications in the lanthanide family species. Keywords: Nanowires, Anodic alumina membranes, Hydroxide electrodeposition, Template, Lanthanide compounds

LanthanideNanostructureMaterials scienceAnodic alumina membranes Hydroxide electrodeposition Lanthanide compounds Nanowires TemplateScanning electron microscopeNanowireMineralogytemplatelanthanide compoundsElectrosynthesisElectrochemistrylcsh:ChemistryMembraneSettore ING-IND/23 - Chimica Fisica ApplicataChemical engineeringlcsh:Industrial electrochemistrylcsh:QD1-999hydroxide electrodepositionnanowires; anodic alumina membranes; hydroxide electrodeposition; template; lanthanide compoundsnanowireX-ray crystallographyElectrochemistryanodic alumina membranelcsh:TP250-261
researchProduct

The application of neutron activation analysis, scanning electron microscope, and radiographic imaging for the characterization of electrochemically …

2008

Lanthanide and actinide targets are prepared at the University of Mainz by molecular plating, an electrochemical deposition from an organic solvent, for heavy-ion reaction studies at GSI. To acquire information about deposition yield, target thickness, and target homogeneity, the following analysis methods are applied. With neutron activation analysis (NAA) the deposition yield and the average thickness of the deposited material is determined. We report on the analytical procedure of NAA performed subsequent to the molecular plating process. Scanning electron microscope (SEM) is used to determine the morphology of the target surfaces. In combination with energy dispersive X-ray spectrometer…

LanthanidePhysicsNuclear and High Energy PhysicsScanning electron microscopeGadoliniumAnalytical chemistrychemistry.chemical_elementActinideUraniumSamariumchemistryNeutron activation analysisHolmiumInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Characterization of laser ablation of copper in the irradiance regime of laser-induced breakdown spectroscopy analysis

2014

Abstract The LIBS signal depends both on the ablated mass and on the plasma excitation temperature. These fundamental parameters depend in a complex manner on laser ablation and on laser–plasma coupling. As several works in the literature suggest that laser ablation processes play a predominant role compared to plasma heating phenomena in the LIBS signal variations, this paper focuses on the study of laser ablation. The objective was to determine an interaction regime enabling to maximally control the laser ablation. Nanosecond laser ablation of copper at 266 nm was characterized by scanning electron microscopy and optical profilometry analysis, in air at 1 bar and in the vacuum. The laser …

Laser ablationMaterials scienceScanning electron microscopebusiness.industrymedicine.medical_treatmentPhysics::Medical PhysicsIrradiancePlasmaExcitation temperatureAblationLaserAtomic and Molecular Physics and OpticsAnalytical Chemistrylaw.inventionOpticsPhysics::Plasma PhysicslawmedicinePhysics::Atomic PhysicsLaser-induced breakdown spectroscopybusinessInstrumentationSpectroscopySpectrochimica Acta Part B: Atomic Spectroscopy
researchProduct

Investigation of the superstructure of native collagen by a combination of small angle X-ray scattering, electron microscopy and light diffraction

1978

It is shown that there exists a direct correlation between the light diffraction pattern of an electron-microscopical picture and the X-ray small angle scattering. By this means it can be proved for native collagen prepared by a special method that the density pattern of stained samples imaged in the electron microscopy is identical with the density pattern available from moist fibres. The reflex intensities of the small angle X-ray scattering are taken for calculating the density structure whereby the necessary phases are delivered by the electron microscopic examination combined with light diffraction.

Light diffractionMaterials sciencePolymers and PlasticsSmall-angle X-ray scatteringScatteringAnalytical chemistrylaw.inventionColloid and Surface ChemistrylawMaterials ChemistryPhysical and Theoretical ChemistryElectron microscopeBiological small-angle scatteringSmall-angle scatteringSuperstructure (condensed matter)Electron microscopicColloid and Polymer Science
researchProduct

Transmission electron microscopical studies on some haemolymph proteins from the marine polychaete Nereis virens.

2001

Abstract The hexagonal bilayer haemoglobin molecule from Nereis virens has been investigated in a comparative study using several different negative stain electron microscopical specimen preparations (i.e. by conventional adsorption to continuous carbon support films, by the negative staining-carbon film technique and by negative staining across the holes of holey carbon support films with air-drying and rapid freezing/cryo-negative staining). The benefits and limitations of these different approaches are indicated, with the overall conclusion that negative staining with ammonium molybdate across holes creates the best possibilities for molecular imaging, and also has the potential for the …

LipoproteinsGeneral Physics and AstronomyNegative Staininglaw.inventionchemistry.chemical_compoundHemoglobinsStructural BiologylawHemolymphHemolymphAnimalsGeneral Materials ScienceAmmonium molybdatebiologyBilayerPolychaetaCell BiologyTrehaloseNegative stainStainingFerritinMicroscopy ElectronchemistryBiochemistryFerritinsbiology.proteinElectron microscopeMicron (Oxford, England : 1993)
researchProduct

1987

Preparation de vesicules contenant une matrice polymere reticule hydrophile (couches bimoleculaires phospholipides revetues de microparticules polymeres)

LiposomePhotopolymerHydrophilyChemical engineeringOptical microscopePolymerizationChemistrylawVesiclePolymer chemistryElectron microscopeLight scatteringlaw.inventionDie Makromolekulare Chemie, Rapid Communications
researchProduct

A comparison between the chemical behaviour of lead-gold and lead-bismuth eutectics towards 316L stainless steel

2013

Radiochimica acta, 101 (10)

Liquid metalLBEScanning electron microscopeIsothermal02 engineering and technology01 natural sciencesIsothermal process010305 fluids & plasmasCorrosion0103 physical sciences540 ChemistrySpallationPhysical and Theoretical ChemistryEutectic systemChemistryChromium AlloysLGEMetallurgySpallation targetAtmospheric temperature range021001 nanoscience & nanotechnologyCorrosion; LGE; LBE; Isothermal; SS 316L; Liquid metal; Spallation targetLiquid metalCorrosion570 Life sciences; biology0210 nano-technologySS 316L
researchProduct

Ultrastructure of alcoholic hyalin and fate of the affected hepatocytes

1977

In liver biopsy specimens, foci of satellitosis, i.e., foci of alcoholic hyalin containing hepatocytes surrounded by accumulated leukocytes, were studied by means of electron-microscopic investigation. Within satellitosis hepatocytes, the same morphologic variants of alcoholic hyalin were observed as formerly described in nonsatellitosis liver cells: (1) clusters of randomly oriented smooth filaments of homogenous electron density, (2) bundles of filaments aligned in parallel arrays and exhibiting irregular densities and indistinct boundaries, and (3) masses of a strongly osmiophilic amorphous material, presumably lipidic in nature. The individual hyalin body was composed of one, two, or al…

Liver CirrhosisHyalinPathologymedicine.medical_specialtymedicine.diagnostic_testHuman liverNeutrophilsChemistryEndoplasmic ReticulumAlcoholic hyalinPathology and Forensic Medicinelaw.inventionStorage materialAlcoholismMicroscopy ElectronLiverlawLiver biopsymedicineUltrastructureHumansElectron microscopeClose contactVirchows Archiv B Cell Pathology
researchProduct

Complement pore genesis observed in erythrocyte membranes by fluorescence microscopic single-channel recording

1991

The formation and opening of single complement pores could be directly observed in erythrocyte ghosts by confocal laser-scanning microscopy employing the recently introduced method of fluorescence microscopic single-channel recording. Resealed sheep erythrocyte ghosts were incubated with human complement. By limiting the concentration of C8, the eighth component of complement, the fraction of cells rendered permeable for the small polar fluorescent probe Lucifer Yellow was varied between 0.50 and 0.90. Under each condition the flux rate, k, of Lucifer Yellow was determined for a substantial number of ghosts. By analysing the sample population distribution of k the flux rate k1 of ghosts wit…

Lucifer yellowPhotolysisSheepScanning electron microscopeConfocalErythrocyte MembraneAnalytical chemistryComplement System ProteinsCell BiologyModels TheoreticalIsoquinolinesBiochemistryFluorescenceKineticschemistry.chemical_compoundMonomerMembraneMicroscopy FluorescencechemistryMicroscopyFluorescence microscopeAnimalsMolecular BiologyFluorescent DyesResearch ArticleBiochemical Journal
researchProduct

Strain Sensing Coatings for Large Composite Structures Based on 2D MXene Nanoparticles

2021

Real-time strain monitoring of large composite structures such as wind turbine blades requires scalable, easily processable and lightweight sensors. In this study, a new type of strain-sensing coating based on 2D MXene nanoparticles was developed. A Ti3C2Tz MXene was prepared from Ti3AlC2 MAX phase using hydrochloric acid and lithium fluoride etching. Epoxy and glass fibre–reinforced composites were spray-coated using an MXene water solution. The morphology of the MXenes and the roughness of the substrate were characterised using optical microscopy and scanning electron microscopy. MXene coatings were first investigated under various ambient conditions. The coating experienced no sign…

MXenes; coatings; strain sensors; electrical properties; cyclic loadingMaterials scienceScanning electron microscopeComposite numbercoatings02 engineering and technologySurface finishengineering.materiallcsh:Chemical technology010402 general chemistry7. Clean energy01 natural sciencesBiochemistryArticleMXenesAnalytical ChemistryCoatingElectrical resistance and conductancelcsh:TP1-1185strain sensorsElectrical and Electronic EngineeringComposite materialInstrumentationcyclic loadingEpoxy021001 nanoscience & nanotechnologyAtomic and Molecular Physics and Optics0104 chemical sciencesGauge factorvisual_artelectrical propertiesengineeringvisual_art.visual_art_medium0210 nano-technologyMXenesSensors
researchProduct