Search results for "Electron microscope"
showing 10 items of 784 documents
Dentin bond strength and degree of conversion evaluation of experimental self-etch adhesive systems
2014
Background: The aim of this study was to investigate the effect of different concentrations of 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) monomer in one-step self-etch experimental adhesives on dentinal microshear bond strength (μSBS), their degree of conversion and bonded micro structure. Material and Methods: Composite resin cylinders (Clearfil AP-X) were bonded on human sound molar dentinal surfaces by using five experimental one-step self-etching adhesives (1-SEAs) containing 0% (E0), 5% (E5), 10% (E10), 15% (E15), 20% (E20) (by weight) 10-MDP monomer and Clearfil S3 Bond (CS3) as a control. After 24 hours, microshear bond strength was tested. The degree of conversion was als…
Evaluation of marginal sealing quality of restorations with low shrinkage composite resins
2020
Background This study compared the quality of marginal sealing in the gingival wall of class II preparations of two low-shirinkage resins of the bulk fill type with a conventional resin isolated or associated with a glass ionomer cement (GIC). Material and methods 40 human molars were divided into 4 groups and 80 occlusal-mesial and occlusal-distal restorations were performed with the following materials: SureFil SDR flow, Filtek Bulk Fill Posterior, Z250 resins and Riva Light Cure GIC. 40 restorations were evaluated in Scanning Electron Microscopy (SEM) with Elemental Microanalysis Spectrometry (EDS) initially and the remainder after a period of 6 months of aging in a 37 ± 5°C oven. An ave…
Effect of rotary cutting instruments on the resin-tooth interfacial ultra structure: An in vivo study
2013
Objectives: To evaluate the effect of cutting teeth with different types of burs at various speeds on surface topogra - phy of tooth surface and interfacial gap formation at resin-tooth interface. Material and Methods: The human molars were divided into seven groups: Diamond bur in airrotor (DA) & mi - cromotor (DM), crosscut carbide bur in airrotor (CCA) & micromotor (CCM), plain carbide bur in airrotor (CA) & micromotor (CM) and #600-grit silicon carbide paper (SiC). In five samples from each group Class II box-only cavities were restored. The occlusal surface of four teeth per group was flattened. Two out of four teeth were acid etched. Teeth were subjected for scanning electron microsco…
Evaluation of periimplant bone neoformation using different scanning electron microscope methods for measuring BIC. A dog study.
2012
Objetives: The aim of this study was to determine which of three methods for measuring BIC (bone-to-implant contact), using vestibular and lingual scanning electron microscopy (SEM) for different implant systems at 15, 30 and 90 days post-surgery was the most precise. An elemental analysis with SEM was used to evaluate neoformed bone composition for three implant systems at the same study times. Material and Methods: 36 implants were placed in eighteen Beagle dogs mandible about one year old and weighing approximately 12-13 kg in order to evaluate bone apposition to three different implant surfaces. It was used the third and fourth premolar and first molar distal sockets in both quadrants o…
Sealing effectiveness of fissure sealant bonded with universal adhesive systems on saliva-contaminated and noncontaminated enamel.
2017
Background The effectiveness of sealants is dependent upon their adhesion to enamel surface. The aim of the study was to evaluate the sealing ability of a pit and fissure sealant used with a universal adhesive (etch-and-rinse vs. self-etch modes) when the site is contaminated with saliva. Adhesive properties were evaluated as microleakage and scanning electron microscopic (SEM) characteristics. Material and methods A total of 72 mandibular third molars were randomly divided into 6 groups (n=12). Occlusal pits and fissures were sealed with an unfilled resin fissure sealant (FS) material with or without saliva contamination. The groups included: 1) phosphoric acid etching + FS (control), 2) p…
On the origin of controlled anisotropic growth of monodisperse gold nanobipyramids
2021
We elucidate the crucial role of the cetyl trimethylammonium bromide (CTAB) surfactant in the anisotropic growth mechanism of gold nano-bipyramids, nano-objects with remarkable optical properties and high tunability. Atomistic molecular dynamics simulations predict different surface coverages of the CTAB (positively charged) heads and their (bromide) counterions as function of the gold exposed surfaces. High concentration of CTAB surfactant promotes formation of gold nanograins in solution that work as precursors for the smooth anisotropic growth of more elongated nano-bipyramidal objects. Nanobipyramids feature higher index facets with respect to nanorods, allowing higher CTAB coverages th…
Flow-through pore characteristics of monolithic silicas and their impact on column performance in high-performance liquid chromatography
2008
Abstract In order to elucidate the role of the flow-through characteristics with regard to the column performance in high-performance liquid chromatography (HPLC) native and n -octadecyl bonded monolithic silica rods and columns, respectively of 100 mm length and 4.6 mm ID with mesopores in the range between 10 and 25 nm and macropores in the range between 0.7 and 6.0 μm were examined by mercury intrusion/extrusion, scanning electron microscopy, image analysis and permeability. The obtained data of the flow-through pore sizes and porosity values as well as surface-to-volume ratio of the stationary phase skeleton enabled to predict their influence to the chromatographic separation efficiency…
Comprehensive pore structure characterization of silica monoliths with controlled mesopore size and macropore size by nitrogen sorption, mercury poro…
2005
The porosity of monolithic silica columns is measured by using different analytical methods. Two sets of monoliths were prepared with a given mesopore diameter of 10 and 25 nm, respectively and with gradated macropore diameters between 1.8 and 7.5 microm. After preparing the two sets of monolithic silica columns with different macro- and mesopores the internal, external and total porosity of these columns are determined by inverse size-exclusion chromatography (ISEC) using polystyrene samples of narrow molecular size distribution and known average molecular weight. The ISEC data from the 4.6 mm analytical monolithic silica columns are used to determine the structural properties of monolithi…
Contribution to the study of framework modification of SAPO-34 and SAPO-37 upon water adsorption by thermogravimetry
1999
Abstract The adsorption–desorption of water vapor in SAPO-34 and SAPO-37 is followed in isobar conditions ( P H 2 O =17.6 mbar ) by thermogravimetry at temperatures from 20°C to 400°C. The phenomenon is reversible in SAPO-34 but not in SAPO-37. The rise in water uptake is the highest at around 60–70°C, i.e. in range where an attack of the frameworks was previously reported. The reversibility (or not) of water adsorption–desorption uptake is linked to this reversible (or not) framework modification. The kinetics of desorption in SAPO-34 is strongly slowed down between 40°C and 60°C. This suggests that the full restructuration of the framework requires some time (700 min in the experimental c…
Effect of Hydrogen and Carbamide Peroxide in Bleaching, Enamel Morphology, and Mineral Composition: In vitro Study
2017
ABSTRACT Aim The aim of the study was to evaluate the bleaching effect, morphological changes, and variations in calcium (Ca) and phosphate (P) in the enamel with hydrogen peroxide (HP) and carbamide peroxide (CP) after the use of different application regimens. Materials and methods Four groups of five teeth were randomly assigned, according to the treatment protocol: HP 37.5% applied for 30 or 60 minutes (HP30, HP60), CP 16% applied for 14 or 28 hours (CP14, CP28). Changes in dental color were evaluated, according to the following formula: ΔE = [(La−Lb)2+(aa−ab)2 + (ba−bb)2]½. Enamel morphology and Ca and P compositions were evaluated by confocal laser scanning microscope and environmenta…