Search results for "Electron microscope"
showing 10 items of 784 documents
Surface Topographies of Glaucoma Drainage Devices and Their Influence on Human Tenon Fibroblast Adhesion
2010
PURPOSE. This study was performed to investigate the surface topography of different glaucoma drainage devices and to determine the effects of surface roughness on cell adhesion of cultured human tenon fibroblasts.METHODS. The surface topography of four widely used devices (Ahmed FP7 and Ahmed S-2; New World Medical, Inc., Rancho Cucamonga, CA; Baerveldt BG101-350; Advanced Medical Optics, Irvine, CA; and Molteno S1; Molteno Ophthalmic Ltd., Dunedin, New Zealand) was investigated by scanning electron microscopy, and roughness was quantified by white-light confocal microscopy. Cells were grown for 72 hours on the surfaces of implants affixed to standard culture dishes. The cells were labeled…
Bond strength of cemented fiber posts to teeth with simulated internal root resorption
2020
Made available in DSpace on 2021-06-25T10:58:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2020-03-01 Background: Teeth with internal root resorption (IRR) have guarded prognosis, considering that IRR defect could influence on the post bond strength. The aim of this study was to evaluate the bond strength and the bond interface between different glass fiber-reinforced posts (FRP) after cementation in teeth with simulated internal root resorption (IRR). Material and Methods: Forty-five (45) human premolar roots with simulated IRR were embedded in acrylic resin blocks and cross-sectioned into two segments, enabling them to be re-approximated by screws. Intracanal medication was inserte…
The Effect of surface topographical changes of two different surface treatments rotary instrument
2018
Background One of the major innovations in endodontics has been the introduction of nickel-titanium (NiTi) alloy. This study evaluated the surface topographical changes of two different surface treatments rotary instrument after instrumentation and sterilization. Material and Methods 240 Extracted teeth were included in this study. 90 new AlphaKite and Revo-S NiTi rotary instruments were selected and divided into two groups (Group A 45 AlphaKite and group B 45 Revo-S). Each group were divided into three subgroups: (A1, B1) n=5 files were used as a control, (A2,B2) n=20 files were used to prepare three root canals using endodontic rotary motor then sterilized by autoclave for one cycle under…
Efficacy of NaOCl/H2O2irrigation and GaAlAs laser in decontamination of root canals in vitro
2003
Background and Objectives To investigate the bactericidal effect of an 809 nm semiconductor laser alone, and in combination with NaOCl/H2O2 irrigation in root canals in vitro. Study Design/Materials and Methods A total of 72 human single-rooted teeth extracted for periodontal reasons were included. The crowns were removed, the roots shortened to a length of 12 mm, and the canals enlarged up to an apical size of #50 file. The specimens were autoclaved and incubated with a suspension of Streptococcus sanguinis (ATCC 10556). Laser irradiation was performed on a PC-controlled XY translation stage. A 200 micron optic fiber was used. Twelve specimens were irradiated at a power output of 1.5, 3.0,…
Synthesis, electron microscopy and X-ray characterization of oxymagnesite, MgO·2MgCO3, formed from amorphous magnesium carbonate
2014
At present, the peculiar compound called oxymagnesite, MgO·2MgCO3, an intermediate formed during thermal decomposition of hydrated magnesium carbonates, has only been described a handful of times without a distinct description of its formation or morphology. In the current work we present the first scanning and transmission electron microscopy images of an oxymagnesite crystal together with its crystallographic data. Oxymagnesite was synthesized in a controlled manner via decomposition of amorphous magnesium carbonates (AMCs) subjected to varying relative humidity. We show that oxymagnesite is formed only when AMC is hydrated above a certain level, which we attribute to structural inequival…
Ultrastructural causes of rupture of hand tendons in patients with rheumatoid arthritis. A transmission and scanning electron microscopic study.
1993
To identify the cause of rupture of hand tendons in patients with rheumatoid arthritis, we studied the underlying ultrastructural changes of the collagenous fibril systems. Samples of the flexor digitorum superficialis (n = 12) and the extensor digitorum communis (n = 20) were taken during tenosynovectomy. Tendons dissected at necropsy (n = 30) served as controls. Specimens were analysed by transmission and scanning electron microscopy. Interfibrillar dysplastic fibrils, "Luse bodies", and intracellular collagen were found in rheumatoid tissues. The diameters of collagen fibrils were significantly reduced compared with the control group (p0.01). The duration of the disease usually correlate…
Synthesis, Optical, and Morphological Studies of ZnO Powders and Thin Films Fabricated by Wet Chemical Methods
2020
Zinc oxide nanoparticles were prepared from Zn5(CO3)2(OH)6 precursor, capped with poly(vinylpyrrolidone) (PVP), and annealed at 600 °
Surfactant-Mediated Morphology and Photocatalytic Activity of α‑Ag2WO4 Material
2018
In the present work, the morphology (hexagonal rod-like vs cuboid-like) of an α-Ag2WO4 solid-state material is manipulated by a simple controlled-precipitation method, with and without the presence of the anionic surfactant sodium dodecyl sulfate (SDS), respectively, over short reaction times. Characterization techniques, such as X-ray diffraction analysis, Rietveld refinement analysis, Fourier-transform (FT) infrared spectroscopy, FT Raman spectroscopy, UV–vis spectroscopy, transmission electron microscopy (TEM), high-resolution TEM, selected area electron diffraction, energy-dispersive X-ray spectroscopy, field emission-scanning electron microscopy (FE-SEM), and photoluminescence emission…
Fracture and fatigue of titanium narrow dental implants: New trends in order to improve the mechanical response
2019
Sixty-four fractured commercially pure titanium (cp-Ti) narrow dental implants (NDIs) with similar macrogeometry and connection designs were studied after different implantation times in humans in order to determine their reliability and to evaluate the causes of the fracture. These NDIs were compared with other similar implants, made with alloyed titanium with 15% Zr and with 12% strained titanium. Original implants were tested under static and fatigue conditions, simulating the tri-axial loads in the mouth by means of a Bionix hydraulic test machine. Fractography was studied using field-emission scanning electron microscopy (FSEM). The results showed that cp-Ti NDI exhibits low strength f…