Search results for "Elution"
showing 10 items of 337 documents
Towards an automatic lab-on-valve-ion mobility spectrometric system for detection of cocaine abuse.
2017
A lab-on-valve miniaturized system integrating on-line disposable micro-solid phase extraction has been interfaced with ion mobility spectrometry for the accurate and sensitive determination of cocaine and ecgonine methyl ester in oral fluids. The method is based on the automatic loading of 500μL of oral fluid along with the retention of target analytes and matrix clean-up by mixed-mode cationic/reversed-phase solid phase beads, followed by elution with 100μL of 2-propanol containing (3% v/v) ammonia, which are online injected into the IMS. The sorptive particles are automatically discarded after every individual assay inasmuch as the sorptive capacity of the sorbent material is proven to b…
Off-line coupling of multidimensional immunoaffinity chromatography and ion mobility spectrometry: A promising partnership.
2015
The extreme specificity of immunoaffinity chromatography (IAC) columns coupled to the high sensitivity of ion mobility spectrometry (IMS) measurements makes this combination really useful for rapid, selective, and sensitive determination of a high variety of analytes in different samples. The capabilities of the IAC-IMS coupling have been highlighted under three different scenarios: (i) multiclass residue analysis using a single IAC column, (ii) multiclass residue analysis using stacked IAC columns, and (iii) isomer analysis. In the first case, the determination of three strobilurin fungicides - azoxystrobin, picoxystrobin, and pyraclostrobin - in water and strawberry juice was considered, …
Observation of interaction forces by investigation of the influence of eluent additives on the retention behavior of aqueous nanoparticle dispersions…
2020
The investigation and subsequent understanding of the interactions of nanomaterials with components of their surrounding media is important to be able to evaluate both potential use cases as well as potential risks for human health and for the environment. To investigate such interactions, asymmetrical flow field-flow fractionation (AF4) is an interesting analytical tool. This statement grounds on the fact that interactions of the analyte with the membrane and with components of the eluent are crucial for the retention behavior of the analyte within the field-flow fractionation (FFF) channel. Therefore, the investigation of the retention behavior provides an insight in the nature of the int…
Immuno-SLM—a combined sample handling and analytical technique
2004
Immuno-supported liquid membrane (immuno-SLM) extraction is a new technique that makes use of antibody (Ab)-antigen interactions as the "extraction force" to drive the mass transfer in a selective way. In immuno-SLM, anti-analyte (Ag) Abs are introduced into the acceptor phase of the SLM unit to trap the Ag that passes from the flowing donor through the SLM into the stagnant acceptor. The amount of immuno-extracted analyte (AbAg) is quantified by connecting the immuno-SLM unit on-line with a non-competitive heterogeneous fluorescence flow immunoassay (FFIA) that makes use of a fluorescein-labeled analyte tracer that titrates the residual excess of Ab present in the acceptor. A restricted ac…
Cubic smoothing splines background correction in on-line liquid chromatography–Fourier transform infrared spectrometry
2010
A background correction method for the on-line coupling of gradient liquid chromatography and Fourier transform infrared spectrometry (LC-FTIR) is proposed. The developed approach applies univariate background correction to each variable (i.e. each wave number) individually. Spectra measured in the region before and after each peak cluster are used as knots to model the variation of the eluent absorption intensity with time using cubic smoothing splines (CSS) functions. The new approach has been successfully tested on simulated as well as on real data sets obtained from injections of standard mixtures of polyethylene glycols with four different molecular weights in methanol:water, 2-propano…
Surface charge fine tuning of reversed-phase/weak anion-exchange type mixed-mode stationary phases for milder elution conditions.
2015
A series of new mixed-mode reversed-phase/weak anion-exchange (RP/WAX) phases have been synthesized by immobilization of N-undecenyl-3-α-aminotropane onto thiol-modified silica gel by thiol-ene click chemistry and subsequent introduction of acidic thiol-endcapping functionalities of different type and surface densities. Click chemistry allowed to adjust a controlled surface concentration of the RP/WAX ligand in such a way that a sufficient quantity of residual thiols remained unmodified which have been capped by thiol click with either 3-butenoic acid or allylsulfonic acid as co-ligands. In another embodiment, performic acid oxidation of N-undecenyl-3-α-aminotropane-derivatized thiol-modifi…
Determination of fatty alcohol ethoxylates and alkylether sulfates by anionic exchange separation, derivatization with a cyclic anhydride and liquid …
2011
A method for the separation, characterization and determination of fatty alcohol ethoxylates (FAE) and alkylether sulfates (AES) in industrial and environmental samples is described. Separation of the two surfactant classes was achieved in a 50:50 methanol-water medium by retaining AES on a strong anionic exchanger (SAX) whereas most FAE were eluted. After washing the SAX cartridges to remove cations, the residual hydrophobic FAE were eluted by increasing methanol to 80%. Finally, AES were eluted using 80:20 and 95:5 methanol-concentrated aqueous HCl mixtures. Methanol and water were removed from the FAE and AES fractions, and the residues were dissolved in 1,4-dioxane. In this medium, este…
N-Propyl-N′-2-pyridylurea-modified silica as mixed-mode stationary phase with moderate weak anion exchange capacity and pH-dependent surface charge r…
2018
Herein, we present a novel silica-based stationary phase modified with N-propyl-N'-2-pyridylurea selector. Due to the weakly basic properties of the pyridine selector and the presence of residual silanols after selector immobilization, a zwitterionic surface with a pI observed at approximately pH 5.5 was measured by electrophoretic light scattering in pH-dependent ζ-potential determinations. The capability of the new N-propyl-N'-2-pyridylurea-modified silica to serve as mixed-mode stationary phase was investigated. For this purpose, it was characterized under RP and HILIC conditions using test mixtures. Subsequent classification of this stationary phase in comparison to in-house and commerc…
Stable-bond polymeric reversed-phase/weak anion-exchange mixed-mode stationary phases obtained by simultaneous functionalization and crosslinking of …
2019
Abstract A polymeric reversed-phase/weak anion exchange (Poly-RP/WAX) mixed-mode stationary phase has been prepared by coating of a poly(3-mercaptopropyl)methylsiloxane film on vinyl-modified silica (100 A, 5 μm) and simultaneous in situ functionalization with N-(10-undecenoyl)-3-aminoquinuclidine as well as crosslinking to the vinyl silica surface by solventless thiol-ene double click reaction. Such bonding chemistry showed greatly enhanced stability compared to brush-type analogs with bifunctional siloxane bonding to silica. Solid-state 29Si-CP/MAS NMR confirmed the immobilization of the siloxane layer. pH-Dependent ζ-potential determinations revealed a high anion-exchange capacity over t…
Surface-anchored counterions on weak chiral anion-exchangers accelerate separations and improve their compatibility for mass-spectrometry-hyphenation
2017
In the present work we propose new variants of chiral stationary phases (CSP) with tert-butylcarbamoylquinine (tBuCQN) as chiral selector molecule. Four tBuCQN-CSPs with distinct bonding chemistries are compared in terms of their pH-dependent surface charge by ζ-potential determinations, by achiral and chiral liquid chromatographic tests and LC-ESI-MS hyphenation. In one embodiment tBuCQN was immobilized on 3-mercaptopropylmethylsilyl-modified silica by thiol-ene click reaction (brush type CSP with selector coverage of 0.38mmol/g). In another embodiment, poly-(3-mercaptopropyl)-methylsiloxane was coated onto vinylized silica particles in presence of tBuCQN and radical initiator. The tBuCQN …