Search results for "Emmetropia"

showing 10 items of 36 documents

Genome-wide association meta-analysis of corneal curvature identifies novel loci and shared genetic influences across axial length and refractive err…

2020

Corneal curvature, a highly heritable trait, is a key clinical endophenotype for myopia - a major cause of visual impairment and blindness in the world. Here we present a trans-ethnic meta-analysis of corneal curvature GWAS in 44,042 individuals of Caucasian and Asian with replication in 88,218 UK Biobank data. We identified 47 loci (of which 26 are novel), with population-specific signals as well as shared signals across ethnicities. Some identified variants showed precise scaling in corneal curvature and eye elongation (i.e. axial length) to maintain eyes in emmetropia (i.e. HDAC11/FBLN2 rs2630445, RBP3 rs11204213); others exhibited association with myopia with little pleiotropic effects …

0301 basic medicinegenetic structuresMedicine (miscellaneous)EmmetropiaGenome-wide association studyVARIANTSGenome-wide association studiesSensory disorders Donders Center for Medical Neuroscience [Radboudumc 12]Cornea0302 clinical medicineRisk FactorsCorneaDatabases GeneticMULTIPLEMyopiaGene Regulatory NetworksEXPRESSION PATTERNS10. No inequalitylcsh:QH301-705.5POPULATIONGeneticseducation.field_of_studymedicine.diagnostic_testHERITABILITYCorneal DiseasesAsian Continental Ancestry Group ; Axial Length Eye ; Cornea ; Corneal Topography ; Databases Genetic ; European Continental Ancestry Group ; Gene Regulatory Networks ; Genetic Loci ; Genetic Predisposition to Disease ; Genome-Wide Association Study ; Humans ; Myopia ; Phenotype ; Polymorphism Single Nucleotide ; Refractometry ; Risk Assessment ; Risk FactorsCorneal topographyEYE SIZE3. Good healthAxial Length EyePhenotypemedicine.anatomical_structureGeneral Agricultural and Biological SciencesExtracellular matrix organizationKeratoconusCorneal diseasesPopulationBiologyPolymorphism Single NucleotideRisk AssessmentArticleWhite PeopleGeneral Biochemistry Genetics and Molecular BiologyOCULAR COMPONENT DIMENSIONS03 medical and health sciencesSPHERICAL EQUIVALENTAsian PeoplemedicineHumansGenetic Predisposition to DiseaseKERATOCONUS3125 Otorhinolaryngology ophthalmologyeducationCorneal Topographymedicine.diseaseCOLLAGENeye diseasesRefractometry030104 developmental biologylcsh:Biology (General)Genetic LociRE3111 Biomedicinesense organs030217 neurology & neurosurgeryGenome-Wide Association StudyCommunications Biology
researchProduct

Influence of the luminance level on visual performance with a disposable soft cosmetic tinted contact lens.

2001

The purpose of the present work was to study the effect on visual performance of wearing disposable soft tinted contact lenses for cosmetic purposes. Parameters such as contrast sensitivity (Vistech 6000), colour vision (Farnsworth-Munsell 100-Hue colour test), visual fields (static Goldmann perimetry) and subjective vision (what the wearer feels while wearing the lenses) were studied under different illumination levels in order to check for possible vision losses while wearing these contact lenses at low illumination levels. Sixteen emmetropic subjects were fitted consecutively with seven pairs of different colour lenses (Optima Colors lenses by BauschLomb), and the experimental parameters…

AdultGoldmann perimetryAdolescentmedia_common.quotation_subjectColour VisionEmmetropiaColorContact Lenses HydrophilicLuminanceSensory SystemsContact lensContrast SensitivityOphthalmologyContrast (vision)OptometryHumansVisual Field TestsVisual FieldsColor PerceptionLightingVision OcularOptometryMathematicsmedia_commonOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

The effect of longitudinal chromatic aberration on the lag of accommodation and depth of field.

2016

Purpose Longitudinal chromatic aberration is present in all states of accommodation and may play a role in the accommodation response and the emmetropisation process. We study the change of the depth of field (DOFi) with the state of accommodation, taking into account the longitudinal chromatic aberration. Methods Subjective DOFi was defined as the range of defocus beyond which the blur of the target (one line of optotypes of 0.1 logMAR shown on a black-and-white microdisplay, seen through different colour filters) was perceived as objectionable. The subject's eye was paralysed and different, previously-measured accommodative states (corresponding to the accommodative demands of 0D, 2D and …

AdultMaleAccommodative responseLag01 natural sciencesDeformable mirror010309 optics03 medical and health sciencesYoung Adult0302 clinical medicineOpticsPhysiological optics0103 physical sciencesChromatic aberrationHumansDepth of fieldMathematicsDepth Perceptionbusiness.industryAccommodation OcularEmmetropiaSensory SystemsOphthalmology030221 ophthalmology & optometryOptometryFemaleMonochromatic colorbusinessAccommodationColor PerceptionPhotic StimulationOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Curvature of iris profile in spectral domain optical coherence tomography and dependency to refraction, age and pupil size - the MIPH Eye&Health …

2016

Purpose Optical coherence tomography (OCT) of the anterior segment allows quantitative analysis of the geometry of the iris. We performed spectral domain OCT examinations in healthy emmetropic, hyperopic and myopic subjects to investigate iris curvature and its associations. Methods In a cross-sectional study, out of 4617 eyes (2309 subjects) those with refractive errors of +3 dioptres were identified by objective refraction. The iris was examined using the anterior segment mode of a spectral domain 3D OCT-2000 (Topcon Inc., Japan) in the temporal meridian, and OCT scans were investigated with respect to presence and amount of convex and concave iris configuration. Ninety-three eyes of 50 s…

AdultMaleAdolescentgenetic structuresGonioscopyIrisEmmetropiaSpectral domainRefraction OcularCurvatureYoung Adult03 medical and health sciences0302 clinical medicineOptical coherence tomographyAnterior Eye SegmentGermanyEye healthHumansMedicineIntraocular PressureAgedmedicine.diagnostic_testbusiness.industryIncidenceAge FactorsPupil sizePupilGeneral MedicineMiddle AgedRefractive ErrorsRefractioneye diseasesOphthalmologyCross-Sectional StudiesMeridian (perimetry visual field)030221 ophthalmology & optometryOptometryFemalesense organsbusinessTomography Optical Coherence030217 neurology & neurosurgeryActa Ophthalmologica
researchProduct

Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliability

2001

Abstract Purpose: To evaluate the intraobserver and interobserver variability in axial length (AL), anterior chamber depth (ACD), and corneal radius measurements using an optical biometry instrument based on partial coherence interferometry (PCI). Setting: Johannes Gutenberg University, Mainz, Germany. Methods: In this observational case series and interobserver reliability trial, 30 healthy, emmetropic to moderately myopic eyes of 15 volunteers were evaluated. The AL, ACD, and corneal radius were measured 20 times in 10 eyes by 1 observer to evaluate the intraobserver variability. To evaluate the interobserver variability, the measurements were taken in 20 eyes by 5 different observers. Me…

AdultMaleBiometryLightInterobserver reliabilityAnterior ChamberEmmetropiaData descriptionCorneaOptical biometryOpticsMyopiaHumansReliability (statistics)AgedMathematicsObserver VariationReproducibilitybusiness.industryCorneal TopographyReproducibility of ResultsMiddle AgedSensory SystemsOphthalmologyInterferometryPartial coherence interferometryFemaleSurgerybusinessNuclear medicinePartial coherenceJournal of Cataract and Refractive Surgery
researchProduct

Image quality and visual performance in the peripheral visual field following photorefractive keratectomy.

2002

ABSTRACT PURPOSE: A theoretical and experimental study was performed to assess the possible effects of photorefractive keratectomy (PRK) on retinal image quality and thresholds in the peripheral visual field. METHODS: Simple optical calculations suggest that although the quality of the retinal image at the fovea of the postoperative PRK eye may be comparable to that in an emmetropic eye, images in the peripheral field may be markedly worse, since peripheral ray bundles may pass partly through ablated and partly through unablated cornea, giving a simultaneous-vision bifocal effect. This would be expected to create an annular zone of confusion, so that light from two different directions in o…

AdultMaleOptics and Photonicsgenetic structuresmedicine.medical_treatmentVisual AcuityEmmetropiaPhotorefractive Keratectomychemistry.chemical_compoundCorneaMyopiaHumansMedicineVision OcularRetinabusiness.industryRetinaleye diseasesPhotorefractive keratectomyVisual fieldOphthalmologymedicine.anatomical_structureMeridian (perimetry visual field)chemistrySensory ThresholdsVisual Field TestsOptometryFemaleLasers ExcimerSurgerysense organsVisual FieldsbusinessPhotopic vision
researchProduct

Postoperative astigmatism and rotational stability after Artisan toric phakic intraocular lens implantation

2003

Abstract Purpose To evaluate deviations in the axis (intended versus achieved) and postoperative astigmatism after implantation of an Artisan toric phakic intraocular lens (IOL). Setting University Eye Hospital, Mainz, Germany. Methods This prospective study comprised 29 eyes with high ametropia and astigmatism. All eyes had uneventful implantation of a toric phakic IOL through a superior scleral tunnel incision at 12 o’clock. After a minimum of 6 months, the uncorrected visual acuity (UCVA), best correct visual acuity, refraction, and astigmatism were analyzed in all eyes. A multivariate analysis of postoperative astigmatism was performed. Results After a follow-up of at least 6 months, 95…

AdultMaleRefractive errorVisual acuityRotationgenetic structuresmedicine.medical_treatmentEmmetropiaIntraocular lensPhakic intraocular lensLens Implantation IntraocularmedicineHumansPostoperative PeriodProspective StudiesDioptreLenses Intraocularbusiness.industryAstigmatismEquipment DesignMiddle AgedRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsRefractive Surgical ProceduresToric lensOphthalmologyMeridian (perimetry visual field)OptometryFemaleSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Mesopic contrast sensitivity function after excimer laser photorefractive keratectomy.

2002

ABSTRACT PURPOSE: To evaluate contrast sensitivity under mesopic conditions in patients who had undergone uncomplicated excimer laser photorefractive keratectomy (PRK) for myopia. METHODS: Monocular contrast sensitivity function was measured with the Stereo Optical ?A.C.T. chart in 26 patients who had received PRK using the Nidek EC-5000 excimer laser system. Mean preoperative refractive error was -6.23 ? 1.69 D (range, -4.00 to -8.25 D); postoperatively, mean refractive error was -0.36 ? 0.58 D (range, -0.75 to +0.50 D). Contrast sensitivity function was measured 6 months after surgery using four different chart luminances: 85, 5.0, 2.5, and 0.1 cd/m2, the first being a photopic level and …

AdultMaleRefractive errormedicine.medical_specialtyMaterials scienceLightMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityEmmetropiaRefraction OcularExcimerPhotorefractive KeratectomyContrast SensitivityOpticsOphthalmologyMyopiamedicineHumansContrast (vision)media_commonExcimer laserbusiness.industrymedicine.diseaseeye diseasesPhotorefractive keratectomyOphthalmologyFemaleLasers ExcimerSurgerybusinessPhotopic vision
researchProduct

Iris Claw Phakic Intraocular Lens for High Myopia

1997

ABSTRACT BACKGROUND: The implantation of a WorstFechner iris claw intraocular lens (IOL) is one of the surgical procedures used for the correction of high myopia. This technique reduces myopia with stähle refractive results; however, its potential long-term risks have not been evaluated. We report results in 94 eyes with a minimum follow -up of 3 years. METHODS: We studied 94 eyes of 62 patients with myopia 5= -7.00 diopters (D) who underwent Worst-Fechner IOL implantation. Lens decentration, permeability of the blood-aqueous barrier by iris angiography, and changes in corneal endothelial density were analyzed. RESULTS: Mean follow-up time was 48.9 months (range 36 to 72 mo). Three years af…

AdultMaleRefractive errormedicine.medical_specialtyTime FactorsVisual acuitygenetic structuresEye diseasemedicine.medical_treatmentVisual AcuityIrisEmmetropiaIntraocular lensRefraction OcularPhakic intraocular lensVision disorderPostoperative ComplicationsOphthalmologyMyopiamedicineHumansDioptreAgedRetrospective StudiesLenses Intraocularbusiness.industryEndothelium CornealMiddle Agedmedicine.diseaseeye diseasesOphthalmologyTreatment OutcomeFemaleSurgerysense organsmedicine.symptombusinessFollow-Up StudiesJournal of Refractive Surgery
researchProduct

Long-term results of surgical treatment of high myopia with Worst-Fechner intraocular lenses

1995

Abstract This retrospective study evaluated the results in 90 eyes that had a minus-power anterior chamber intraocular lens implanted to correct high myopia. Preoperative myopia ranged from −7.00 to −24.00 D. Postoperative spherical equivalent was −0.50 D; 80.5% of eyes were within 1.00 D of emmetropia. Two years postoperatively, no cataract formation, retinal detachment, glaucoma, or significant endothelial damage had occurred. We conclude that minus-power lenses can rapidly, safely, and predictably correct high myopia in phakic patients.

AdultMaleRefractive errormedicine.medical_specialtygenetic structuresAnterior ChamberEye diseasemedicine.medical_treatmentVisual AcuityEmmetropiaGlaucomaIntraocular lensProsthesis DesignVision disorderPostoperative ComplicationsOphthalmologyMyopiamedicineHumansLongitudinal StudiesAgedRetrospective StudiesLenses Intraocularbusiness.industryRetinal detachmentRetrospective cohort studyMiddle AgedPrognosismedicine.diseaseeye diseasesSensory SystemsOphthalmologyFemaleSurgerysense organsmedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct