Search results for "Endoscopy"
showing 10 items of 524 documents
Recognition and characterization of small colonic neoplasia with high-definition colonoscopy using i-Scan is as precise as chromoendoscopy
2010
Abstract Background The EPKi system (Pentax, Japan) enables resolution above HDTV. Aim of the study was to test the efficacy of HD+ alone and with the new post-processing digital filter i-Scan or chromoendoscopy (Methylene blue 0.1%) in screening for colorectal cancer. We focused on lesions less than 5 mm as a surrogate marker for the optical possibilities of the EPKi system. Methods The last 30 cm of the colon in a screening population were inspected with HD+ alone, in combination with i-Scan (2:1 randomisation) and subsequently with chromoendoscopy. All lesions were characterized and targeted biopsies were performed. Results i-Scan augmented in 69 patients the identification of lesions fr…
Accuracy of the water-siphon test associated to barium study in a high prevalence gastro-oesophageal reflux disease population: a novel statistical a…
2010
Summary Rationale, aims and objectives Gastro-oesophageal reflux disease (GORD) is ‘a condition which develops when the reflux of gastric content causes troublesome symptoms or complications’. Instrumental diagnostic tests generally used for GORD are 24-hour pH-metry and upper gastrointestinal (GI) endoscopy but barium study associated with provocative manoeuvres such as the water-siphon test (WST), has also been used for GORD. The aim of this paper was to estimate the accuracy of several tests in patients with GORD in a tertiary care setting, focusing on WST, which is rapid and non-invasive, simple to perform and well-tolerated by patients. Method A total of 172 consecutive patients, sym…
Molecular endoscopic imaging: the future is bright
2019
The prediction and final survival rate of gastrointestinal cancers are dependent on the stage of disease. The ideal would be to detect those gastrointestinal lesions at early stage or even premalignant forms which are difficult to detect by conventional endoscopy with white light optical imaging as they show minimum or no changes in morphological characteristics and are thus left untreated. The introduction of molecular imaging has greatly changed the pattern for detecting gastrointestinal lesions from purely macroscopic structural imaging to the molecular level. It allows microscopic examination of the gastrointestinal mucosa with endoscopy after the topical or systemic application of mol…
Endoscope-assisted Craniotomy
1995
We describe a surgical technique to improve visualization of deep brain structures during craniotomy. The technique, developed in a cadaveric model, combines the use of an operating microscope and a solid-rod lens endoscope. Addition of the endoscope during craniotomy allows the operator to visualize structures that otherwise might not have been seen. An approach to the brain stem is demonstrated.
Endoscopic training during fellowship: A nationwide French study
2022
ABSTRACT Background In France, it is mandatory that gastroenterology fellows have mastered the basic level of endoscopy by the end of training. The aim of this study was to assess improvement in the quality of fellows’ endoscopy training in France during the last four years. Methods All fellows in France in training were eligible for participation. A 21-item questionnaire was sent out. The primary outcome was the completion by fourth year fellows of all the number of procedures recommended. Results were compared with those of a 2016 survey. Results Two-hundred-and-sixty-five fellows responded to the survey. The participation rate was 47.0%. The mean age was 27.3 ± 1.0 years and 56.4% were f…
Instruments Used for Endoscopy of Anus and Rectum
1979
In the discussion of endoscopic instruments and additional tools, we have referred only to the general features and important principles since instruments from individual firms not only vary in details but are also being continuously modified. The characteristics of any specific instrument may be obtained from its manufacturer.
Endoscopic Treatment of Intracranial Arachnoid Cysts: A Retrospective Analysis of a 25-Year Experience.
2020
Background Since the development of neuroendoscopy, pure endoscopic fenestration for intracranial arachnoid cysts (ACs) became more and more popular and is actually preferred by many neurosurgeons. Objective To explore their techniques and experiences with endoscopic treatment of intracranial ACs over a 25-yr period. Methods A total of 95 endoscopic procedures in 87 patients with 88 intracranial ACs performed at the authors' departments between February 1993 and October 2018 were retrospectively analyzed. Particular respect was given to surgical technique, complications, patients' outcome, and radiological benefit in relation to cyst location. Results Patients' ages ranged from 23 d to 81 y…
Surveillance colonoscopy in ulcerative colitis: magnifying chromoendoscopy in the spotlight
2004
Chromoendoscopy in ulcerative colitis may offer the possibility of detecting dysplastic or neoplastic changes at a curable stage, and thus expand the indication for chromoendoscopy from screening to surveillance colonoscopy Colonoscopy is the gold standard for colorectal cancer screening.1–3 Detection and complete removal of adenomas disrupt the adenoma-carcinoma sequence and thus prevent the development of colorectal cancer. However, endoscopists still fear that they may have overlooked relevant lesions despite the availability of modern videoendoscopes. This problem is underlined by a relatively high rate of adenomas missed by conventional endoscopy (up to 27%), as determined by back to b…
In vitro evaluation of forces exerted by a new computer-assisted colonoscope (the NeoGuide Endoscopy System).
2006
Background: The NeoGuide Endoscopy System (NES) utilizes a fully articulated, computer-controlled insertion tube that allows proximal segments of the colonoscope to follow the path taken by the tip as it is manually advanced through the colon. The system was designed to eliminate looping and scope displacement during colonoscopy. Material and methods: Using in vitro testing, an inanimate flexible model of the colon incorporating four force transducers located at the key flexure points was employed to measure the axial forces on the colon wall during colonoscopy. In the second part of the study, 10 gastroenterologists performed colonoscopies, using a training latex-based simulator, with the …
Conventional Radiology in the Evaluation of the Small Bowel
2015
For many years, the small bowel has been considered as the “black box” of the gastrointestinal system because it could not be evaluated through endoscopy. For this reason, the conventional radiological methods, such as small bowel enteroclysis and small bowel follow-through, have been considered the standard approach for the evaluation of the small bowel in the diagnosis and management of Crohn’s disease for years. However, due to technological limits, the study of small bowel through conventional radiology has been focused mainly on its function than on its anatomy. To date, the conventional examination with the study of intestinal transit is now rarely used, if not obsolete, but it has st…