Search results for "Endosseous"
showing 10 items of 119 documents
Influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient satisfaction
2016
Background: To assess the influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient comfort and stability, speech, functionality and overall satisfaction. Material and Methods: A retrospective clinical study was made of patients subjected to rehabilitation of atrophic maxilla with complete maxillary implant-supported fixed prostheses involving a minimum of two zygomatic implants (one on each side) in conjunction with premaxillary implants, and with 12 months of follow-up after implant loading. Subjects used a VAS to score general satisfaction, comfort and stability, speech and functionality, and the results were analyzed in relation to the prosthetic arm l…
Soft and hard tissue alterations around implants placed in an alveolar ridge with a sloped configuration.
2012
Aim: The aim of this study was to evaluate soft and hard tissue alterations around implants placed in healed, sloped ridge sites. Materials and methods: In this prospective multi-center study, 65 patients between 20 and 74 years of age and with a need for a single tooth replacement were included. All patients presented with a recipient implant site demonstrating a lingual‐buccal bone height discrepancy of 2.0‐5.0 mm and with a neighboring tooth on its mesial aspect. Implant placement (OsseoSpeed Profile implants; Astra Tech AB, M! olndal, Sweden) was performed using a non-submerged installation procedure. The implants were placed in such a way that the sloped part of the device was located …
Clinical parameters of implants placed in healed sites using flapped and flapless techniques: A systematic review
2017
Background: Dental implant placement using flapless surgery is a minimally invasive technique that improves blood supply compared with flapped surgery. However, the flapless technique does not provide access to allow bone regeneration. Objectives: The aim of this systematic review was to evaluate the clinical parameters following implant surgery in healed sites, using two procedures: flapped vs. flapless surgery. Material and Methods: A detailed electronic search was carried out in the PubMed/Medline, Embase and Cochrane Library databases. The focused question was, “How do flapped and flapless surgical techniques affect the clinical parameters of dental implants placed in healed sites?”. Al…
Are mucous retention cysts and pseudocysts in the maxillary sinus a risk factor for dental implants? A systematic review
2020
Background Mucous retention cysts and pseudocysts of the maxillary sinus are benign lesions present in up to 13% of adult patients. Different surgical approaches for sinus lift and dental implant placement in the presence of these lesions have been proposed. Material and Methods A systematic review was performed following the PRISMA statement recommendations to answer the PICO question: Does the aspiration or removal of mucous retention cysts/pseudocysts before or during sinus lifting and dental implant placing, affect the survival of the implants? The study was pre-registered in PROSPERO (CRD42020185528). Included articles quality was assessed using the “NIH quality assessment tool” and “T…
Complications in Oral Implant Placement
2020
The placement of dental endosseous implants is a safe and reliable routine method for functional and esthetic rehabilitation of partial or total edentulism. Even so, there is an immanent potential for both short- and long-term complications in oral implant placement leading to not only minor but also major impairments of the affected patients. Most of the complications occur unexpected while others will be iatrogenic.
Implant treatment in atrophic posterior mandibles: Vertical regeneration with block bone grafts versus implants with 5.5-mm intrabony length
2014
Purpose: To retrospectively compare the outcomes of implants placed in posterior mandibles vertically regenerated with onlay autogenous block bone grafts and short dental implants. Materials and Methods: Consecutive patients with vertical bone atrophy in edentulous mandibular posterior regions (7 to 8 mm of bone above the inferior alveolar nerve) were treated with either implants placed in regenerated bone using autologous block bone grafts (group 1) or short implants (with 5.5-mm intrabony length) in native bone (group 2) between 2005 and 2010 and followed for 12 months after loading. The procedure used was the established treatment protocol for this type of patient at the Oral Surgery Uni…
Preoperative Evaluation and Treatment Planning. Zygomatic Implant Critical Zone (ZICZ) Location
2021
Soft tissue integration of different abutment surfaces: An experimental study with histological analysis
2021
OBJECTIVE To evaluate whether abutment surface and surface bio-activation have an effect on soft tissue morphogenesis. MATERIALS AND METHODS 36 patients (36 implants) were included. Abutments were randomly divided into 4 groups (n = 9): Smooth Surface-MAChined (MAC), Ultrathin Threaded Microsurface (UTM), MAC Plasma of Argon activated (Plasma-MAC), and UTM Plasma of Argon activated (Plasma-UTM). After 2 months of healing, soft tissue samples were collected and prepared for histological analysis. The margin of the peri-implant mucosa (PM), the apical extension of the barrier epithelium (aJE), and the apical location of the abutment (AM) were identified. Significances of differences among gro…
Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement.
2011
Objectives The aim of the present investigation was the analysis of the factors presumptively affecting the accuracy outcome of cone-beam computed tomography (CBCT)-derived laboratory-based surgical guides for implant placement in partially edentulous patients. Materials and methods In 52 partially edentulous patients a total of 132 implants were placed following CBCT diagnostics with the aid of laboratory-fabricated, tooth-borne templates. Based on the image fusion technique measurements were done to calculate linear and angular deviations between virtually planned and placed implants. The implant sites were stratified according to four factors that presumably may influence the transfer ac…
Implant insertion torque value in immediate loading : a retrospective study
2019
Background The aim of this study is to verify if the Insertion Torque Value (ITV) of 32 Ncm for immediate loading protocol (ILP), as indicated by literature, is still, with the advance in implant research, a real significant cut-off for long-term implant survival. Material and Methods In this retrospective study, data from 224 patients that during three years of clinical practice, were submitted to the insertion of 322 implants with immediate loading protocol, have been recorded, pooled and analyzed. Data were organized based on Insertion Torque Value (ITV): > 32 Ncm (CG) and 32 Ncm are still characterized by a lower crestal bone resorption, there are no statistically significant difference…