Search results for "Endovascular procedures"
showing 10 items of 130 documents
Anticoagulation with argatroban for elective percutaneous coronary intervention: population pharmacokinetics and pharmacokinetic-pharmacodynamic rela…
2010
The synthetic direct thrombin inhibitor argatroban has a rapid onset and offset of anticoagulation. However, there are no data about the pharmacokinetic-pharmacodynamic (PK-PD) relationship of argatroban in patients undergoing contemporary percutaneous coronary intervention (PCI) and no data about other coagulation parameters than activated clotting time (ACT) in this setting. In the ARG-E04-trial, 140 patients were randomly assigned to argatroban (250, 300, or 350 μg/kg as bolus before PCI, followed by 15, 20, or 25 μg/kg/min infusion) or unfractionated heparin (70-100 IU/kg bolus). A 2-compartment model with first-order elimination adequately described the pharmacokinetic profile of argat…
Haemodynamic predictors of a penetrating atherosclerotic ulcer rupture using fluid-structure interaction analysis
2013
We present preliminary data on the flow-induced haemodynamic and structural loads exerted on a penetrating atherosclerotic aortic ulcer (PAU). Specifically, one-way fluid-structure interaction analysis was performed on the aortic model reconstructed from a 66-year-old male patient with a PAU that evolved into an intramural haematoma and rupture of the thoracic aorta. The results show that elevated blood pressure (117 mmHg) and low flow velocity at the aortic wall (0.15 m/s(2)) occurred in the region of the PAU. We also found a low value of time-averaged wall shear stress (1.24 N/m(2)) and a high value of the temporal oscillation in the wall shear stress (oscillatory shear index = 0.13) in t…
FLOW DIVERTER DEVICE IN THE ACUTE SETTING OF RUPTURED BLISTER LIKE ANEURYSM: A CASE REPORT
2021
Blister-like aneurysms (BLA) are a rare half-dome-shaped aneurysm, with a broad-based appearance, originating more often from a non-branching site of the supraclinoid internal carotid artery (ICA). They are sometimes difficult to recognize due to their morphological changes and high tendency to rupture. BLAs are often undiagnosed and may be detected only after repeated angiograms in the case of acute subarachnoid hemorrhage (SAH). BLA are life-threatening and no consensus has so far been reached on the best management strategy. We describe a patient with a BLA in the left ICA successfully treated by flow-diverting device using intraoperative abciximab bolus, with successful results. Recentl…
Improved technique for sheath supported contralateral limb gate cannulation in endovascular abdominal aortic aneurysm repair
2019
Summary: Background: To present a technique of sheath supported contralateral limb gate (CLG) cannulation of modular bifurcated stent-graft in endovascular abdominal aortic repair. Materials and methods: After totally percutaneous bilateral femoral access, the 9F introducer sheath is exchanged to a 30 cm 12 fr introducer sheath over a stiff wire contralateral to the intended main stent-graft insertion side and advanced into the aorta below the lowest renal artery. Parallel to the stiff wire within the sheath an additional standard J-tip guidewire with a 5 fr Pigtail angiographic catheter is advanced to the level of the renal arteries. After main body deployment, the 12 fr introducer sheath…
New 3-zone hybrid graft : First-in-man experience in acute type I dissection
2019
Abstract Objective Acute type I aortic dissection (AAD) represents a surgical emergency with time-dependent evolving complications. Frozen elephant trunk (FET) enables false lumen exclusion downstream but is still debated in AAD due to its greater dimension of surgery. To combine the benefits of fast proximal repair with the FET benefits, a 3-zone hybrid graft was developed consisting of an ascending polyester portion, an arch noncovered stent, and a descending stent graft. Mid-term results of this new technique are presented. Methods A total of 6 patients (age mean 69 years) with type I AAD in critical status (Penn classification B n = 5, BC n = 1) were operated between July 2016 and April…
Survival and reinterventions after isolated proximal aortic repair in acute type A aortic dissection.
2018
OBJECTIVES Conventional treatment for acute type A dissection is the replacement of the ascending aorta. This study demonstrates the results of a conventional approach with isolated proximal repair combined with concomitant endovascular procedures. METHODS Replacement of the ascending aorta with or without an open distal anastomosis was defined as isolated proximal repair and was performed in 562/588 patients between January 2004 and June 2017. A total of 68% were DeBakey type I and 32% were DeBakey type II aortic dissections. Concomitant procedures were thoracic endovascular aortic repair (3.6%); visceral, renal and iliac stents (2%); and peripheral bypasses (1.1%). Mean follow-up was 4.6 …
Strategies for endovascular aortic repair in aortobronchial and aortoesophageal fistulas.
2013
Objective To report our experience of thoracic endovascular aortic repair (TEVAR) for acute bleeding originating from the thoracic aorta in patients with aortobronchial fistula (ABF) or aortoesophageal fistula (AEF). Patients and Methods A total of nine patients (three woman) were treated from September 1995 to March 2012 by TEVAR for ABF (n = 5) and AEF (n = 4). The implants (N = 14) were introduced with fluoroscopic guidance via the aorta (n = 1), the iliac (n = 2), or femoral (n = 11) artery, respectively. Results All aortic lesions could be sealed successfully. Perioperative morbidity was 0% in the ABF group and 50% (2 of 4) in the AEF group and no procedure-related morbidity was noted …
Contemporary spinal cord protection during thoracic and thoracoabdominal aortic surgery and endovascular aortic repair: a position paper of the vascu…
2015
Ischaemic spinal cord injury (SCI) remains the Achilles heel of open and endovascular descending thoracic and thoracoabdominal repair. Neurological outcomes have improved coincidentially with the introduction of neuroprotective measures. However, SCI (paraplegia and paraparesis) remains the most devastating complication. The aim of this position paper is to provide physicians with broad information regarding spinal cord blood supply, to share strategies for shortening intraprocedural spinal cord ischaemia and to increase spinal cord tolerance to transitory ischaemia through detection of ischaemia and augmentation of spinal cord blood perfusion. This study is meant to support physicians cari…
German Registry for Acute Aortic Dissection Type A (GERAADA)--new software design, parameters and their definitions.
2011
BACKGROUND The working group for aortic surgery and interventional vascular surgery of the German Society for Thoracic and Cardiovascular Surgery (GSTCVS) initiated the web-based German Registry for Acute Aortic Dissection type A (GERAADA). It is the project's aim to collect standardized data from a large pool of patients with acute aortic dissections type A (AADA) to gain a deeper insight and knowledge to improve surgical therapies and perioperative management for these patients in the future. METHODS In addition to new medical insights, the working group has gained more experience over the last 4 years in how to collect valid and high-quality data. This experience led us to revise the dat…
Aortic remodelling after thoracic endovascular aortic repair in acute and chronic type B aortic dissections
2019
AbstractOBJECTIVESType B aortic dissections are routinely treated with thoracic endovascular aortic repair (TEVAR). The timing for TEVAR remains controversial and might have an impact on the remodelling capacity of the aorta. This study analyses and compares aortic remodelling in acute (ABD) and chronic (CBD) type B aortic dissections after TEVAR.METHODSThis retrospective study analysed the preoperative, postoperative and at least 1-year follow-up computed tomography of 53 TEVAR patients (36 ABD, 17 CBD) at a single institution between May 2005 and May 2016. The volumes of aortic lumen (AL), true lumen, false lumen (FL) and perfused FL were measured at the stent graft level (A), from the st…