Feasibility, reproducibility, and reliability for the T*2 iron evaluation at 3 T in comparison with 1.5 T
2012
This study aimed to determine the feasibility, reproducibility, and reliability of the multiecho T * 2 Magnetic resonance imaging technique at 3 T for myocardial and liver iron burden quantification and the relationship between T * 2 values at 3 and 1.5 T. Thirty-eight transfusion-dependent patients and 20 healthy subjects were studied. Cardiac segmental and global T * 2 values were calculated after developing a correction map to compensate the artifactual T * 2 variations. The hepatic T * 2 value was determined over a region of interest. The intraoperator and interoperator reproducibility for T * 2 measurements at 3 T was good. A linear relationship was found between patients' R (1000/T * …
Tumori gastrointestinali stromali: Aspetti con tomografia computerizzata multidetettore (40-strati)
2006
Purpose. The purpose of this study was to describe the findings and evaluate the role of multidetector (40-slice) computed tomography (MDCT) in the preoperative assessment of gastrointestinal stromal tumours (GISTs). Materials and methods. Thirteen patients with histologically proven GIST (size: 4-30 cm; mean: 9 cm) underwent 40-slice MDCT after the ingestion of 1,000 ml of water. Images were obtained before and 70 s after intravenous injection of 120 ml of iodinated contrast agent. Two experienced radiologists reviewed the CT findings to evaluate lesion site, size, margins, attenuation, growth pattern, enhancement pattern, ascites, lymphadenopathy, direct invasion to adjacent organs and di…
TC perfusionale nell'ischemia cerebrale acuta: Valore predittivo dei parametri di perfusione cerebrale nel discriminare il tessuto vitale da quello i…
2007
Purpose. The aim of this study was to assess the value of computed tomography (CT) perfusion parameters in differentiating tissue viability in acute stoke patients. Materials and methods. Thirteen patients (mean age 63.3 years) with nonhaemorrhagic stroke underwent multidetector perfusion CT within 3 h of symptom onset. Images were continuously acquired at the basal ganglia over 40 s during injection of 90 ml of iodinated contrast medium injected at a rate of 9 ml/s with a 9-s delay. Z-axis coverage was 20 mm. All patients underwent diffusion-weighted magnetic resonance imaging (DWI) within 12 h of perfusion CT to define the extent of the infarct. Perfusion CT data were analysed in regions …
Assessment of left ventricular function by breath-hold cine MR imaging: Comparison of different steady-state free precession sequences
2005
Purpose To compare steady-state free precession (SSFP) sequence protocols with different acquisition times (TA) and temporal resolutions (tRes) due to the implementation of a view sharing technique called shared phases for the assessment of left ventricular (LV) function by breath-hold cine magnetic resonance (MR) imaging. Materials and Methods End-diastolic and end-systolic volumes (EDV, ESV) were measured in contiguous short-axis slices with a thickness of 8 mm acquired in 10 healthy male volunteers. The following true fast imaging with steady-state precession (TrueFISP) sequence protocols were compared: protocol A) internal standard of reference, segmented: tRes 34.5 msec, TA 18 beats pe…
Life context of pharmacological academic performance enhancement among university students – a qualitative approach
2014
Background Academic performance enhancement or cognitive enhancement (CE) via stimulant drug use has received increasing attention. The question remains, however, whether CE solely represents the use of drugs for achieving better academic or workplace results or whether CE also serves various other purposes. The aim of this study was to put the phenomenon of pharmacological academic performance enhancement via prescription and illicit (psycho-) stimulant use (Amphetamines, Methylphenidate) among university students into a broader context. Specifically, we wanted to further understand students’ experiences, the effects of use on students and other factors, such as pressure to perform in thei…
[Esophageal digital videofluorography with water siphon test in the post-operative evaluation of the anti-reflux laparoscopic surgery].
2004
Background: In recent years digital videoefluorography (VFG) with water siphon test (WST) has been proposed just for diagnosing biatal bernia and/or gastroesophageal reflux. Patients and Methods: Fifteen patients undergone Laparoscopic Nissen (LN) for complicated GFRD associated to biatal bernia, were referred for VFG and WST in order to evaluate the functional results of surgery. At one- month videofluorographic control thirteen patients had just a minimal prolonged esophageal transit time hut only six of these had an early postoperative dysphagia, whereas at six montJh control the prolonged esophageal transit time was present in three patients two of which complained a very light dysphagi…
Characterization of Small Incidental Indeterminate Hypoattenuating Hepatic Lesions: Added Value of Single-Phase Contrast-Enhanced Dual-Energy CT Mate…
2018
OBJECTIVE. The objective of this study is to determine whether single-phase contrast-enhanced dual-energy CT (DECT) material attenuation analysis improves the characterization of small (< 2.0 cm) incidental indeterminate hypoattenuating hepatic lesions, compared with conventional single-energy CT evaluation. MATERIALS AND METHODS. This retrospective study involved 55 patients (24 men and 31 women; mean [± SD] age, 63.9 ± 15.3 years) with 77 incidental hypoattenuating hepatic lesions (59 benign and 18 malignant lesions) measuring 0.5–2.0 cm who underwent single-phase contrast-enhanced DECT of the abdomen for pain. For each lesion, attenuation measurements were obtained using blended 120-k…
High definition plus colonoscopy combined with i-scan tone enhancement vs. high definition colonoscopy for colorectal neoplasia: A randomized trial
2014
High definition endoscopy is the accepted standard in colonoscopy. However, an important problem is missed polyps.Our objective was to assess the additional adenoma detection rate between high definition colonoscopy with tone enhancement (digital chromoendoscopy) vs. white light high definition colonoscopy.In this prospective randomized trial patients were included to undergo a tandem colonoscopy. The first exam was a white light colonoscopy with removal of all visualized polyps. The second examination was randomly assigned in a 1:1 ratio as either again white light colonoscopy (Group A) or colonoscopy with tone enhancement (Group B). Primary endpoint was the adenoma detection rate during t…
Relevance of dynamic studies with magnetic resonance enterography in Crohn's disease.
2020
A proper quantification of the inflammatory activity in Crohn's disease (CD) lesions is needed to establish the appropriate management for each patient. The aim of this study is to evaluate the inflammatory activity of affected segments in small bowel lesions using dynamic studies of magnetic resonance enterography (MRE) in patients undergoing surgery, and their correlation with the level of inflammation and histological fibrosis of the surgical piece.A prospective, consecutive, observational, clinical study was conducted that included all the patients with small bowel CD that underwent surgery in this center between March 2011 and September 2013. Diagnosis was established according to Lenn…
MRI findings in lingual venous malformations.
2003
To describe the plain and enhanced MRI findings of lingual venous malformations and to discuss the importance of contrast medium in the differential diagnosis of high intensity lesions of the tongue on T(2) weighted images.The clinical records and MR images of eight patients affected by a lingual venous malformation were retrospectively reviewed. Patients presented with a palpable submucosal bluish-red soft mass in the tongue. MRI examinations were performed on a 0.5 T superconducting unit. Plain and enhanced SE (spin echo) T(1) weighted and FSE (fast spin echo) T(2) weighted images were acquired in axial, sagittal and coronal planes. Axial SPGR (spoiled gradient recalled echo) T(1) weighte…