Search results for "Equipment Design"
showing 10 items of 409 documents
Numerical study for a new methodology of flaws detection in train axles
2013
Train loads and travel speeds have increased over time, requiring more efficient non-destructive inspection methods. Railway axles are critical elements; despite being designed to last more than 20 years several cases of premature failure have been recorded. Train axles are inspected regularly, but the limits associated to the traditional inspection technologies create a growing interest towards new solutions. Here a novel non-destructive inspection method of in-service axles based on non-contact data collection is presented. The propagation of surface waves, generated by a thermo-elastic laser source, is investigated using a finite element method based on dynamic explicit integration. Coup…
Photo-acoustic excitation and optical detection of fundamental flexural guided wave in coated bone phantoms.
2013
Abstract Photo-acoustic (PA) imaging was combined with skeletal quantitative ultrasound (QUS) for assessment of human long bones. This approach permitted low-frequency excitation and detection of ultrasound so as to efficiently receive the thickness-sensitive fundamental flexural guided wave (FFGW) through a coating of soft tissue. The method was tested on seven axisymmetric bone phantoms, whose 1- to 5-mm wall thickness and 16-mm diameter mimicked those of the human radius. Phantoms were made of a composite material and coated with a 2.5- to 7.5-mm layer of soft material that mimicked soft tissue. Ultrasound was excited with a pulsed Nd:YAG laser at 1064-nm wavelength and received on the s…
Determination of Bubble Size Distribution Using Ultrasound Array Imaging
2020
In this article, ultrasonic phased arrays are deployed as an imaging tool for industrial process analysis. Such arrays are typically used for sonar, medical diagnosis, and nondestructive testing; however, they have not yet been applied to industrial process analysis. The precise positioning of array elements and high frequencies possible with this technology mean that highly focused images can be generated, which cannot currently be achieved using ultrasound tomography. This article aims to highlight the potential of this technology for the measurement of bubble size distribution (BSD) and to demonstrate its application to both intrusive and noninvasive process measurements. Ultrasound imag…
Mesenchymal stem cell proliferation and differentiation on load-bearing trabecular Nitinol scaffolds.
2013
Bone tissue regeneration in load-bearing regions of the body requires high-strength porous scaffolds capable of supporting angiogenesis and osteogenesis. 70% porous Nitinol (NiTi) scaffolds with a regular 3-D architecture resembling trabecular bone were produced from Ni foams using an original reactive vapor infiltration technique. The "trabecular Nitinol" scaffolds possessed a high compressive strength of 79 MPa and high permeability of 6.9×10(-6) cm2. The scaffolds were further modified to produce a near Ni-free surface layer and evaluated in terms of Ni ion release and human mesenchymal stem cell (hMSC) proliferation (AlamarBlue), differentiation (alkaline phosphatase activity, ALP) and …
Polarized multiplex coherent anti-Stokes Raman scattering using a picosecond laser and a fiber supercontinuum
2011
International audience; We perform multiplex coherent anti-Stokes Raman scattering (CARS) micro-spectroscopy with a picosecond pulsed laser and a broadband supercontinuum (SC) generated in photonic crystal fiber. CARS signal stability is achieved using an active fiber coupler that avoids thermal and mechanical drifts. We obtain multiplex CARS spectra for test liquids in the 600–2000 cm−1 spectral range. In addition we investigate the polarization dependence of the CARS spectra when rotating the pump beam linear polarization state relative to the linearly polarized broad stokes SC. From these polarization measurements we deduce the Raman depolarization ratio, the resonant versus nonresonant …
Ion-Selective Organic Electrochemical Transistors
2014
Ion-selective organic electrochemical transistors with sensitivity to potassium approaching 50 μA dec(-1) are demonstrated. The remarkable sensitivity arises from the use of high transconductance devices, where the conducting polymer is in direct contact with a reference gel electrolyte and integrated with an ion-selective membrane.
In vitro power profiles of daily disposable contact lenses
2012
Abstract Purpose To evaluate and compare the distribution of refractive power within the optic zone of different soft contact lenses and to investigate the effect of lens decentration on the power profiles. Methods The Nimo TR1504 instrument was used to measure the optical power across different aperture diameters (from 1.5 mm to 5.5 mm in steps of 0.5 mm) of four daily disposable contact lenses: DAILIES TOTAL1, Proclear 1-Day, SofLens daily disposable and 1-DAY ACUVUE MOIST. Measurements were performed using a wet cell. Power data were evaluated when contact lenses were in its centered position and after inducing different amounts of lens decentration (from 0.2 mm to 1.0 mm in steps of 0.2…
Optical power distribution of refractive and aspheric multifocal contact lenses: Effect of pupil size
2015
Abstract Purpose To evaluate the power profile within the optic zone of different designs of multifocal contact lenses (CLs) and to analyze how the effect of pupil size could impact on their optical performance. Methods The optical power distribution within the optic zones of multifocal CLs was measured by the Nimo TR1504 (LAMBDA-X, Belgium). The multifocal CLs under study were the Acuvue Bifocal, the Acuvue Oasys for Presbyopia, the PureVision Multifocal and the PureVision 2 for Presbyopia. Each design was considered in all their available addition powers. All lenses had a nominal power of −3.0D. At the same time, three lenses of each model were considered and five consecutive readings of …
Easy-use and low-cost fiber-based two-color dynamic light-scattering apparatus
2011
We present a small and compact two-color cross-correlation light-scattering setup designed to study the structure and dynamics of colloidal suspensions in the regime of considerable turbidity. Using a homemade concentric four-arm goniometer, combined with fiber-optical illumination and detection devices, allows an easy and long time stable alignment-even under a temperature variation of ∼5 °C. Tests with a nearly multiple scattering free suspension of small Rayleigh scatterers show intercepts in cross correlation near 0.4 over a wide range of scattering angles from 20° to 150°. Measuring slightly turbid samples in cross-correlation mode multiple scattering is sufficiently suppressed allowin…
Features of randomized electric-field assisted domain inversion in lithium tantalate
2011
We report on bulk and guided-wave second-harmonic generation via random Quasi-Phase-Matching in Lithium Tantalate. By acquiring the far-field profiles at several wavelengths, we extract statistical information on the distribution of the quadratic nonlinearity as well as its average period, both at the surface and in the bulk of the sample. By investigating the distribution in the two regions we demonstrate a non-invasive approach to the study of poling dynamics.