Search results for "Equipment Design"
showing 10 items of 409 documents
Indications and limitations of the fixator TGF “Gex-Fix” in proximal end humeral fractures
2014
Abstract The incidence of fractures of the humerus has increased exponentially in recent years. The most used classifications for humerus fracture are morphological (Neer), biological (AO/ASIF) and descriptive (Hertel). The types of surgical treatment for humerus fracture include prosthetic replacement and synthesis using different devices, including the Tension Guide Fixator (TGF), Gex-Fix. External fixation for displaced proximal humeral fractures avoids dissection and soft tissue stripping and has been reported by some authors to be associated with higher union rates, a lower incidence of avascular necrosis, less scarring of the scapulohumeral interface, and faster rehabilitation compare…
Comparison of cyclodeviation and duction measurement in Graves' orbitopathy patients using different devices
2011
To compare measurement outcomes of different devices measuring cyclodeviation and ductions in Graves' orbitopathy (GO) patients. Cyclodeviation in GO patients was measured using the Harms tangent screen (HTS), the cycloforometer of Franceschetti, and the synoptometer. Ductions were measured using the modified perimeter, the Goldmann perimeter and the Maddox tangent scale (MTS). In 13 patients, cyclodeviation in primary position, up-, and downgaze was measured with the above-mentioned devices. The mean differences ranged from 0.3º to 3.1º and were smallest between the HTS and the cycloforometer (89% of all measurements within 2º difference). Measurement of abduction, adduction, elevation, an…
Capsule Endoscopy versus Push Enteroscopy in Patients with Occult Gastrointestinal Bleeding
2003
Background Wireless capsule endoscopy is a new method enabling non-invasive diagnostic endoscopy of the entire small intestine. In this study we prospectively examined the diagnostic precision of capsule endoscopy compared with push enteroscopy in patients with occult gastrointestinal bleeding. Methods Between July 2001 and October 2002 we examined 48 patients with suspected disorders of the small intestine using capsule endoscopy. 33 patients with obscure bleeding (19 men, 14 women, mean age 58 +/- 23 years) were prospectively examined using capsule endoscopy and push enteroscopy. Results On average, the patients had been suffering from chronic gastrointestinal bleeding for 30 +/- 36 (1-12…
Safety and efficacy of an intra-oral electrostimulator for the relief of dry mouth in patients with chronic graft versus host disease: case Series
2013
Objectives: Patients with chronic graft-versus-host disease (cGVHD) often suffer from dry mouth and oral mucosal lesions. The primary objective of this study was to investigate the safety of an intra-oral electrostimulator (GenNarino) in symptomatic cGVHD patients. The secondary objective was to study the impact on the salivary gland involvement of cGVHD patients. Study Design: This paper presents a case series. The study included patients treated for 4 weeks, randomly assigned to the active device and then crossed-over to a sham-device or vice versa. The patients and clinicians were blind to the treatment delivered. Data regarding oral mucosal and salivary gland involvement were collected.…
Effects of mat characteristics on plantar pressure patterns and perceived mat properties during landing in gymnastics.
2011
Shock absorption and stability during landings is provided by both, gymnast ability and mat properties. The aims of this study were to determine the influence of different mat constructions on their energy absorption and stability capabilities, and to analyse how these properties affect gymnast's plantar pressures as well as subjective mat perception during landing. Six mats were tested using a standard mechanical drop test. In addition, plantar pressures and subjective perception during landing were obtained from 15 expert gymnasts. The different mats influenced plantar pressures and gymnasts' subjective perception during landing of gymnasts. Significant correlations between plantar pressu…
Reliability of knee extension and flexion measurements using the Con-Trex isokinetic dynamometer.
2007
The aim of this study was to evaluate the reliability of isokinetic and isometric assessments of the knee extensor and the flexor muscle function using the Con-Trex isokinetic dynamometer. Thirty healthy subjects (15 males, 15 females) were tested and retested 7 days later for maximal strength (isokinetic peak torque, work, power and angle of peak torque as well as isometric maximal voluntary contraction torque and rate of torque development) and fatigue (per cent loss and linear slope of torque and work across a series of 20 contractions). For both the knee extensor and the flexor muscle groups, all strength data - except angle of peak torque - demonstrated moderate-to-high reliability, wi…
Transcrestal sinus lift and implant placement using the sinus balloon technique
2011
Objective: A description is made of transcrestal sinus lift using the sinus balloon technique, evaluating the bone height achieved and implant success one year after prosthetic loading. Material and method: Between January and July 2007, transcrestal sinus lift using the sinus balloon technique for dental implant placement was carried out in 6 patients. A panoramic X-ray study and maxillary computed tomography scan were carried out before the operation, in order to discard possible sinus pathology. During the intervention, the integrity of the sinus membrane was evaluated using a Medi Pack Pal endoscope (Farol Store and Co., Tuttlingen, Germany), and the intraoperative complications were an…
Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressure
2011
We validated a prototype cuff-free device for noninvasive estimation of blood pressure (BP). The system assumed a linear relation between BP values and the inverse of arterial blood pulse transit time, measured as time interval between the R wave on the electrocardiograph and the onset of the peripheral pulse wave on a finger plethysmogram. Thirty-three healthy subjects were analyzed at rest and during increasing stress exercise. To estimate subject-specific linear model parameters, the system was calibrated ad personam with reference to BP measures obtained by a cuff sphygmomanometer. High correlation values (R2= 0.89 and 0.78 for systolic and diastolic BP, respectively) and differences co…
Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Performance of Single Lead VDD Pacemakers
2002
WIEGAND, U.K.H., et al.: Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Perfor-mance of Single Lead VDD Pacemakers. Intermittent atrial undersensing is observed in a considerable percentage of patients with single lead VDD pacemakers. Analyzing the 2-year data of the Saphir Multicenter Follow-Up Study, the authors investigated predictors for the occurrence of undersensing. The study included 194 patients with high degree AV block who received a VDD pacemaker system with an identical sensing amplifier. Placement strategy of the atrial dipole was left to the discretion of the implanting physician. At the final position, atrial potential amplitudes were measured during deep …
Optimal Response to Cardiac Arrest study: Defibrillation waveform effects
2001
Abstract Introduction: Advances in early defibrillation access, key to the “Chain of Survival”, will depend on innovations in defibrillation waveforms, because of their impact on device size and weight. This study compared standard monophasic waveform automatic external defibrillators (AEDs) to an innovative biphasic waveform AED. Material and methods: Impedance-compensated biphasic truncated exponential (ICBTE) and either monophasic truncated exponential (MTE) or monophasic damped sine (MDS) AEDs were prospectively, randomly assigned by date in four emergency medical services. The study design compared ICBTE with MTE and MDS combined. This subset analysis distinguishes between the two clas…