Search results for "Equipment failure"

showing 10 items of 150 documents

Effect of saliva contamination on bracket failure with a self-etching primer: A prospective controlled clinical trial

2010

Introduction The aim of this study was to evaluate in vivo the effect of saliva contamination at different stages of the bonding procedure on the bond failure rate and the adhesive remaining on teeth after debonding brackets bonded with a hydrophilic self-etching primer (Transbond Plus self-etching primer [TSEP], 3M Unitek, Monrovia, Calif). Methods This was a prospective controlled clinical trial. The sample consisted of 46 patients with similar treatment plans and mechanotherapies. Stainless steel brackets (n = 531) were bonded with TSEP. The patients were divided into 2 groups: contamination with saliva before TSEP application and contamination with saliva after TSEP application. In both…

Curing Lights DentalCuspidSalivaOrthodontic BracketsSurface PropertiesDentistryOrthodonticsDental bondingDental Debondingstomatognathic systemIncisorOrthodontic WiresHumansMedicineProspective StudiesSaliva contaminationDental EnamelSalivaDental Debondingbusiness.industryBracketDental BondingStainless SteelResin CementsIncisorClinical trialstomatognathic diseasesSelf etchmedicine.anatomical_structureEquipment FailurebusinessDental AlloysFollow-Up StudiesAmerican Journal of Orthodontics and Dentofacial Orthopedics
researchProduct

Effect of cyclic loading on fracture strength and microleakage of a quartz fiber dowel with different adhesive, cement and resin core material combin…

2010

Background: This study evaluated the performance of different adhesive-cement-core combinations coupled with quartz fiber dowels after cyclic loading and fracture strength tests and assessed the microleakage using dye penetration method. Methods: Forty maxillary canines (n=10 per group) were restored with fiber dowels (Quartz fiber DT Light Post) and four adhesive-cement-core material combinations [(Group 1: All-Bond 2+C&B (root) / All-Bond 2+Biscore (core); Group 2: All-Bond 2+Bisfil 2B (root) / All-Bond 2+Bisfil 2B (core); Group 3: Scotchbond 1+RelyX ARC (root) / Scotchbond 1+Supreme (core); Group 4: RelyX Unicem (root) / Scotchbond 1+Filtek Supreme (core)]. The specimens were initially c…

CuspidDental CementsEquipment DesignQuartzCyclic loading Fiber dowels Fracture strength MicroleakageComposite ResinsPermeabilityPolyethylene GlycolsResin CementsWeight-BearingResins SyntheticPolymethacrylic AcidsSettore MED/28 - Malattie OdontostomatologicheDentin-Bonding AgentsMaterials TestingMethacrylatesBisphenol A-Glycidyl MethacrylateEquipment FailureStress MechanicalPost and Core Technique
researchProduct

Influence of the type of reciprocating motion on the cyclic fatigue resistance of reciprocating files in a dynamic model

2021

Abstract Background The aim of this study was to compare the influence of two novel reciprocating movements on the cyclic fatigue resistance of endodontic reciprocating files. Methods 30 Procodile® (Komet Medical, Lemgo, Germany) files were selected in this study and distributed according to the following study groups depending on the movements to be performed: ReFlex Dynamic (n = 10), ReFlex Smart (n = 10) and Reciproc (n = 10) reciprocating movement. These files were fixed to a specific dynamic cyclic fatigue device designed and manufactured by 3D impression to simulate the pecking motion performed by the operator. The time to failure and the number of cycles of in-and-out of the endodont…

Cyclic stressStudy groupsCyclic fatigueEndodontics03 medical and health sciencesReciprocating motion0302 clinical medicineGermanyMaterials Testing0502 economics and businessEndodontic filesHumansMedicineGeneral DentistryTitaniumOrthodonticsbusiness.industry05 social sciencesEquipment Design030206 dentistryNitinollcsh:RK1-715lcsh:DentistryReflexEquipment Failure050211 marketingReciprocating movementbusinessRoot Canal PreparationResearch ArticleBMC Oral Health
researchProduct

Tooth-implant connection in removable denture.

2016

When the patient cannot be rehabilitated with a fixed denture, or when he does not succeed in adapting to a traditional removable denture, a possible alternative solution consists in the use of a limited number of implants, placed in strategic positions in the arches of the patient, and subsequently connected to their residual teeth. The aim of this review is to evaluate the progress made on connections between teeth and implants in removable denture, to analyze their advantages and disadvantages and to compare the survival rate, both of the teeth and of the implants used as abutments, present in the various studies taken into examination, with the aim of being able to evaluate the effectiv…

Dental ImplantsCrownsJaw Edentulous PartiallyDental AbutmentsDenture OverlayDental implants - Denture partial removable - Survival rateOtorhinolaryngologyDental Prosthesis DesignSettore MED/28 - Malattie OdontostomatologicheQuality of LifeDenture Partial RemovableHumansSurgeryEquipment FailureDental Prosthesis Implant-SupportedStress MechanicalOral SurgeryDenture DesignMinerva stomatologica
researchProduct

In vitro comparison of the retention capacity of new aesthetic brackets.

1999

Tensile bond strength and bond failure location were evaluated in vitro for two types of aesthetic brackets (non-silanated ceramic, polycarbonate) and one stainless steel bracket, using bovine teeth as the substrate and diacrylate resin as the adhesive. The results show that metallic bracket had the highest bond strength (13.21 N) followed by the new plastic bracket (12.01 N), which does not require the use of a primer. The non-silanated ceramic bracket produced the lowest bond strength (8.88 N). Bond failures occurred mainly between bracket and cement, although a small percentage occurred between the enamel-cement interface with the metal and plastic brackets and within the cement for the …

Dental Stress AnalysisCeramicsMaterials scienceOrthodontic BracketsSurface PropertiesDentistryOrthodonticsEsthetics DentalAcid Etching DentalAdhesivesTensile StrengthUltimate tensile strengthAluminum OxideAnimalsOrthodontic Appliance DesignBisphenol A-Glycidyl MethacrylateCeramicComposite materialDental EnamelCementAnalysis of VariancePolycarboxylate CementEnamel paintbusiness.industryBond strengthBrackettechnology industry and agricultureDental BondingStainless SteelSubstrate (building)visual_artvisual_art.visual_art_mediumCattleEquipment FailureAdhesiveStress MechanicalbusinessEuropean journal of orthodontics
researchProduct

Shaping ability of nickel-titanium rotary instruments in simulated S-shaped root canals.

2009

Objective The aim of this study was to compare the shaping ability of 4 nickel-titanium rotary techniques and 1 hand technique in simulated S-shaped curved root canals. Study design Seventy-five simulated double-curved resin root canals were divided into 5 groups (n = 15). The canals were compared at 12 different levels and at 3 different times: before preparation and after preparation to master apical 25 and 35. Data were statistically analyzed by performing 2-by-2 comparisons with the Tukey parametric test of variance analysis using a confidence interval of 95%. Results All of the 75 resin blocks presented transportation of the root canals by transforming the apical curvature into a strai…

Dental Stress AnalysisDental InstrumentsFlexibility (anatomy)Hand techniqueRoot (chord)Normal DistributionDentistryCurvatureNickelmedicineHumansTooth RootPliabilityGeneral DentistryParametric statisticsMathematicsTitaniumAnalysis of Variancebusiness.industryStructural engineeringStainless SteelModels Dentalmedicine.anatomical_structureOtorhinolaryngologyNickel titaniumSurgeryEquipment FailureOral SurgeryDental Pulp CavitybusinessRoot Canal PreparationDental AlloysOral surgery, oral medicine, oral pathology, oral radiology, and endodontics
researchProduct

Osseointegration of miniscrews: a histomorphometric evaluation.

2007

SUMMARY Mini-implants and miniscrews are commonly used in orthodontics to provide additional temporary intraoral anchorage. Partial osseointegration represents a distinct advantage in orthodontic applications, allowing effective anchorage to be combined with easy insertion and removal. This article reports the histomorphometric fi ndings of the osseointegration of bracket screw bone anchors (BSBAs). In an experimental animal study, four BSBAs were inserted in the alveolar process of the lower jaw in each of fi ve male beagle dogs, aged 6.5 months from the same mother. Eleven screws were lost during the study, nine of them due to lack of primary stability. One screw was removed at the end of…

Dental Stress AnalysisMaleTime FactorsBone ScrewsDentistryMandibleBone anchorhistomorphometryOsseointegrationStatistics NonparametricDogsImplants ExperimentalOsseointegrationIndependent samplesAlveolar ProcessOrthodontic Anchorage ProceduresMedicineAnimalsOrthodonticsMiniaturizationbusiness.industryAlveolar processBracketMandibleExperimental animalmedicine.anatomical_structureDental Stress Analysismini screwsEquipment FailurebusinessorthodonticsEuropean journal of orthodontics
researchProduct

A new interface to couple thin-layer chromatography with laser desorption/atmospheric pressure chemical ionization mass spectrometry for plate scanni…

2005

An interface to allow on-line qualitative and quantitative full-plate detection and analysis of compounds separated by thin-layer chromatography (TLC) is presented. A continuous wave diode laser is employed as a desorption source. Atmospheric pressure chemical ionization mass spectrometry ionizes and subsequently identifies the desorbed sample molecules. Besides direct laser desorption on untreated TLC plates, graphite particles were used as a matrix to couple in the laser power and improve the efficiency of desorption.

Desorption electrospray ionizationChromatographyMatrix-assisted laser desorption electrospray ionizationChemistryOrganic ChemistryAnalytical chemistryEquipment DesignMass spectrometryIon sourceSoft laser desorptionAnalytical ChemistryAtmospheric-pressure laser ionizationSpecimen HandlingEquipment Failure AnalysisSystems IntegrationAtmospheric PressureSpectrometry Mass Matrix-Assisted Laser Desorption-IonizationDirect electron ionization liquid chromatography–mass spectrometry interfaceSpectroscopyAmbient ionizationRapid communications in mass spectrometry : RCM
researchProduct

Liquid crystal spatial light modulator with very large phase modulation operating in high harmonic orders.

2013

Unusually large phase modulation in a commercial liquid crystal spatial light modulator (LCSLM) is reported. Such a situation is obtained by illuminating with visible light a device designed to operate in the infrared range. The phase modulation range reaches 6π radians in the red region of the visible spectrum and 10π radians in the blue region. Excellent diffraction efficiency in high harmonic orders is demonstrated despite a concomitant and non-negligible Fabry–Perot interference effect. This type of SLM opens the possibility to implement diffractive elements with reduced chromatic dispersion or chromatic control.

DiffractionMaterials scienceLightInfraredbusiness.industryColorEquipment DesignDiffraction efficiencyAtomic and Molecular Physics and OpticsLiquid CrystalsEquipment Failure AnalysisRefractometryOpticsOptical modulatorInterferometryDispersion (optics)Materials TestingOptoelectronicsComputer-Aided DesignScattering RadiationChromatic scalebusinessPhase modulationLightingVisible spectrumOptics letters
researchProduct

A mixed FES/EMG system for real time analysis of muscular fatigue

2010

International audience; In this article, we present a functional electrical stimulator allowing the extraction in real time of M-wave characteristics from resulting EMG recodings in order to quantify muscle fatigue. This system is composed of three parts. A Labview software managing the stimulation output and electromyogram (EMG) input signal, a hardware part amplifying the output and input signal and a link between the two previous parts which is made up from input/output module (NIdaq USB 6251). In order to characterize the fatigue level, the Continuous Wavelet Transform is applied yielding a local maxima detection. The fatigue is represented on a scale from 0 for a fine shaped muscle to …

Engineering0206 medical engineering02 engineering and technologyElectromyographyUSBSensitivity and SpecificitySignallaw.invention03 medical and health sciences0302 clinical medicinelawElectronic engineeringmedicineHumansMuscle SkeletalSimulationContinuous wavelet transformMuscle fatiguemedicine.diagnostic_testElectromyographybusiness.industryReproducibility of ResultsWavelet transformEquipment Design020601 biomedical engineeringElectric Stimulation[SPI.TRON] Engineering Sciences [physics]/Electronics[ SPI.TRON ] Engineering Sciences [physics]/Electronics[SPI.TRON]Engineering Sciences [physics]/ElectronicsEquipment Failure AnalysisMaxima and minimaMuscle Fatiguemedicine.symptombusinessAlgorithmsSoftware030217 neurology & neurosurgeryMuscle ContractionMuscle contraction2010 Annual International Conference of the IEEE Engineering in Medicine and Biology
researchProduct