Search results for "Equipment"
showing 10 items of 1271 documents
Highly Sensitive Detection of Naphthalene in Solvent Vapor Using a Functionalized PBG Refractive Index Sensor
2012
We report an optical refractive index sensor system based on a planar Bragg grating which is functionalized by substituted γ-cyclodextrin to determine low concentrations of naphthalene in solvent vapor. The sensor system exhibits a quasi-instantaneous shift of the Bragg wavelength and is therefore capable for online detection. The overall shift of the Bragg wavelength reveals a linear relationship to the analyte concentration with a gradient of 12.5 ± 1.5 pm/ppm. Due to the spectral resolution and repeatability of the interrogation system, this corresponds to acquisition steps of 80 ppb. Taking into account the experimentally detected signal noise a minimum detection limit of 0.48 ± 0.05 pp…
Comparison of the solid-phase extraction efficiency of a bounded and an included cyclodextrin-silica microporous composite for polycyclic aromatic hy…
2016
Solid-phase extraction is one of the most important techniques for sample purification and concentration. A wide variety of solid phases have been used for sample preparation over time. In this work, the efficiency of a new kind of solid-phase extraction adsorbent, which is a microporous material made from modified cyclodextrin bounded to a silica network, is evaluated through an analytical method which combines solid-phase extraction with high-performance liquid chromatography to determine polycyclic aromatic hydrocarbons in water samples. Several parameters that affected the analytes recovery, such as the amount of solid phase, the nature and volume of the eluent or the sample volume and …
Use of radiation sources with mercury isotopes for real-time highly sensitive and selective benzene determination in air and natural gas by different…
2015
A new analytical portable system is proposed for the direct determination of benzene vapor in the ambient air and natural gas, using differential absorption spectrometry with the direct Zeeman effect and innovative radiation sources: capillary mercury lamps with different isotopic compositions ((196)Hg, (198)Hg, (202)Hg, (204)Hg, and natural isotopic mixture). Resonance emission of mercury at a wavelength of 254 nm is used as probing radiation. The differential cross section of benzene absorption in dependence on wavelength is determined by scanning of magnetic field. It is found that the sensitivity of benzene detection is enhanced three times using lamp with the mercury isotope (204)Hg in…
Production and detection of atomic hexadecapole at Earth's magnetic field
2007
Anisotropy of atomic states is characterized by population differences and coherences between Zeeman sublevels. It can be efficiently created and probed via resonant interactions with light, the technique which is at the heart of modern atomic clocks and magnetometers. Recently, nonlinear magneto-optical techniques have been developed for selective production and detection of higher polarization moments, hexadecapole and hexacontatetrapole, in the ground states of the alkali atoms. Extension of these techniques into the range of geomagnetic fields is important for practical applications. This is because hexadecapole polarization corresponding to the $\Delta M=4$ Zeeman coherence, with maxim…
Changes in Body Composition in Anorexia Nervosa : Predictors of Recovery and Treatment Outcome
2015
The restoration of body composition (BC) parameters is considered to be one of the most important goals in the treatment of patients with anorexia nervosa (AN). However, little is known about differences between AN diagnostic subtypes [restricting (AN-R) and binge/purging (AN-BP)] and weekly changes in BC during refeeding treatment. Therefore, the main objectives of our study were twofold: 1) to assess the changes in BC throughout nutritional treatment in an AN sample and 2) to analyze predictors of BC changes during treatment, as well as predictors of treatment outcome. The whole sample comprised 261 participants [118 adult females with AN (70 AN-R vs. 48 AN-BP), and 143 healthy controls].…
Synthesis and biological evaluation of abietic acid derivatives
2009
A series of C18-oxygenated derivatives of abietic acid were synthesized and evaluated for their cytotoxic, antimycotic, and antiviral activities. In general, the introduction of an aldehyde group at C18 did improve the resultant bioactivity, while the presence of an acid or alcohol led to less active compounds.
Candida biofilms on implanted biomaterials: a clinically significant problem.
2006
In recent years there has been an increasing appreciation that microbial biofilms are ubiquitous, which has resulted in a number of studies on infectious diseases from a biofilm perspective. Biofilms are defined as structured microbial communities that are attached to a surface and encased in a matrix of exopolymeric material. A wide range of biomaterials used in clinical practice have been shown to support colonization and biofilm formation by Candida spp., and the increase in Candida infections in the last decades has almost paralleled the increase and widespread use of a broad range of medical implant devices, mainly in populations with impaired host defenses. Formation of Candida biofil…
Spectroelectrochemistry of cytochrome c and azurin immobilized in nanoporous antimony-doped tin oxide
2011
Stable immobilization of two redox proteins, cytochrome c and azurin, in a thin film of highly mesoporous antimony-doped tin oxide is demonstrated via UV-vis spectroscopic and electrochemical investigation.
CardioPulse: developments in the treatment of aortic aneurysms in 2014
2015
Since the introduction of EndoVascular Aortic Repair (EVAR) for the treatment of abdominal aortic aneurysms (AAA) more than 20 years ago, the technique has evolved rapidly, from tubular grafts for fairly simple abdominal aortic anatomy, to bifurcated, fenestrated, branched, or parallel grafts for complex aortic aneurysms, no longer confined to the infrarenal abdominal aorta.
Early results of a low-profile stent-graft for thoracic endovascular aortic repair
2020
Purpose To assess outcomes of a low-profile thoracic stent-graft in the treatment of thoracic aortic pathologies. Methods A retrospective analysis of all consecutive patients with aortic thoracic pathologies treated with the RelayPro device in two university hospitals between October 2018 and July 2019. Results 23 patients (65% men; mean age 63.4 ± 15 years) were treated. Pathologies included aortic dissections (n = 10), 5 residual type A (22%) and 5 type B (22%), 6 degenerative aortic aneurysms (26%), 4 penetrating aortic ulcers (17%), and aortic erosion, intramural hematoma and aortic rupture (n = 1 and 4% in each case). Two cases (9%) were emergent and two urgent. Proximal landing was a…