Search results for "Errors"
showing 10 items of 279 documents
Curvature of iris profile in spectral domain optical coherence tomography and dependency to refraction, age and pupil size - the MIPH Eye&Health …
2016
Purpose Optical coherence tomography (OCT) of the anterior segment allows quantitative analysis of the geometry of the iris. We performed spectral domain OCT examinations in healthy emmetropic, hyperopic and myopic subjects to investigate iris curvature and its associations. Methods In a cross-sectional study, out of 4617 eyes (2309 subjects) those with refractive errors of +3 dioptres were identified by objective refraction. The iris was examined using the anterior segment mode of a spectral domain 3D OCT-2000 (Topcon Inc., Japan) in the temporal meridian, and OCT scans were investigated with respect to presence and amount of convex and concave iris configuration. Ninety-three eyes of 50 s…
Repeatability assessment of biometric measurements with different refractive states and age using a swept-source biometer
2018
Background We aim to assess if refractive error or age may influence the repeatability of measurements using a swept-source biometer. Methods A total of 61 subjects were evaluated with IOLMaster 700 acquiring measurements of axial length (AL), central corneal thickness (CCT), white-to-white distance (WTW), anterior aqueous depth (AQD), lens thickness (LT), and keratometry (K) readings. Repeatability was evaluated classifying the sample according to the refractive state and age by the calculation of the within-subject standard deviation (Sw), coefficient of repeatability, and intraclass correlation coefficient. Results Very similar Sw was acquired among groups for AL, CCT, and WTW. Differenc…
Auditory event-related potentials over medial frontal electrodes express both negative and positive prediction errors
2015
International audience; While the neuronal activation in the medial frontal cortex is thought to reflect higher-order evaluation processes of reward prediction errors when a reward deviates from our expectation, there is increasing evidence that the medial frontal activity might express prediction errors in general. However, given that several studies examined the medial frontal event-related potentials (ERPs) by comparing signals triggered by different stimuli and different anticipations, it remains an open question whether the medial frontal signals are sensitive to the valence of prediction errors. Here we orthogonally manipulated expectation magnitude (i.e., large/small expectation) and…
Interchangeability among five devices that measure anterior eye distances.
2014
The aim was to study the interchangeability of various devices that measure anterior chamber depth (ACD) and white-to-white (WTW) distance.Eighty right eyes of eighty patients aged 20 to 40 years were included. Their spherical equivalent ranged from -4.25 to +1.00 dioptres. Each eye's ACD and the WTW distance were measured using the following devices: a Castroviejo surgical calliper, CA-200F Corneal Analyser, Orbscan II, Pentacam HR and IOLMaster 500.The Pentacam HR measured significantly greater ACD (p0.01) than the other two devices, whereas IOLMaster 500 and Orbscan II yielded comparable (p0.01) distances. Nonetheless, in every device comparison, the mean difference was within clinically…
In Lysinuric Protein Intolerance system y+L activity is defective in monocytes and in GM-CSF-differentiated macrophages
2010
Abstract Background In the recessive aminoaciduria Lysinuric Protein Intolerance (LPI), mutations of SLC7A7/y+LAT1 impair system y+L transport activity for cationic amino acids. A severe complication of LPI is a form of Pulmonary Alveolar Proteinosis (PAP), in which alveolar spaces are filled with lipoproteinaceous material because of the impaired surfactant clearance by resident macrophages. The pathogenesis of LPI-associated PAP remains still obscure. The present study investigates for the first time the expression and function of y+LAT1 in monocytes and macrophages isolated from a patient affected by LPI-associated PAP. A comparison with mesenchymal cells from the same subject has been a…
Role of sensorimotor areas in early detection of motor errors: An EEG and TMS study
2019
Abstract Action execution is prone to errors and, while engaged in interaction, our brain is tuned to detect deviations from what one expects from other’s action. Prior research has shown that Event-Related-Potentials (ERPs) are specifically modulated by the observation of action mistakes interfering with goal achievement. However, in complex and modular actions, embedded motor errors do not necessarily produce an immediate effect on the global goal. Here we dissociate embedded motor goals from global action goals by asking subjects to observe familiar but untrained knotting actions. During knotting an embedded motor error (i.e. the rope is inserted top-down instead of bottom-up during the …
Precision of a commercial hartmann-shack aberrometer: limits of total wavefront laser vision correction.
2012
Purpose To assess the intrasession and intersession precision of higher-order aberrations (HOAs) measured using a commercial Hartmann-Shack wavefront sensor (Zywave; Bausch & Lomb) in refractive surgery candidates. Design Prospective, experimental study of a device. Methods To analyze intrasession repeatability, 1 experienced examiner measured 30 healthy eyes 5 times successively. To study intersession reproducibility, the same clinician obtained measurements from another 30 eyes in 2 consecutive sessions at the same time of day 1 week apart. Results For intrasession repeatability, excellent intraclass correlation coefficients (ICCs) were obtained for total ocular aberrations, total HOAs, a…
Explicit and implicit memory biases in depression and panic disorder.
2000
The purpose of the present study was to investigate the presence of a bias for emotional information (panic-related, depression-related, positive and neutral) in explicit memory and implicit memory (by means of free recall and word-stem completion tasks, respectively) among depressed (N=20) and panic (N=20) patients. Three different encoding conditions (graphemic, semantic and self-reference) were used. The results of this study failed to show the existence of a mood-congruent memory bias for both implicit and explicit memory in these emotional disorders. According to the correlational analyses performed, differences among categories of emotional words meant less than the difference among v…
Cholinesterase variants: rapid characterisation by PCR/SSCP and evidence for molecular homogeneity.
1995
We have applied the technique of PCR-SSCP (polymerase chain reaction-single stranded conformation polymorphism) to characterise the molecular basis of cholinesterase deficiency and variants in a Jordanian family. PCR-SSCP proved to be a quick and sensitive method of screening cholinesterase variants in a clinical setting. An AG insertion at position 351 was found to cause a silent allele, for which the parents were heterozygous and three children homozygous. In addition, the father and two sons were heterozygous for an A to G transition at position 209, known to cause the dibucaine resistant variant. No linkage to the K variant was found, which has been reported previously in white populati…
Subjective Satisfaction in Long-term Orthokeratology Patients
2013
Purpose: To AU3 evaluate the subjective satisfaction in visual stability, night vision complains, and light distortion phenomena, and also the number of hours and days per week of lens wear, in patients with myopia undergoing orthokeratology (OK) treatment for at least 1 year. Methods: A visual analog scale (VAS) questionnaire containing 18 items was administered to 44 patients, 29 women and 15 men (mean age, 24.39 6 9.11 years), with a baseline spherical equivalent refractive error of 22.40 6 0.94 diopters and astigmatism up to 20.5 diopters. Average treatment period by the time of data collection was 19 6 7 months. Patients rated their satisfaction with the correction, with complaints of …