Search results for "Evaluation studies"
showing 10 items of 112 documents
Echocardiography in diagnosis of aortic dissection.
1989
In a multicentre study the accuracy of echocardiography was measured in 164 consecutive patients with suspected aortic dissection. The diagnosis was subsequently proven (82 patients) on the basis of transthoracic and transoesophageal echocardiography and additional diagnostic procedures, including computed tomography (CT), aortic angiography, and surgery and/or necropsy. The sensitivity and specificity of echocardiography were 99% and 98%, respectively, with positive and negative predictive values of 98% and 99%. For CT sensitivity was 83%, specificity 100%, and positive and negative predictive values 100% and 86%, respectively. For aortography sensitivity and specificity were 88% and 94%, …
Macular edema computer-aided evaluation in ocular vein occlusions.
1998
This paper is concerned with the use of digital fundus imaging to detect, quantify, and follow up macular angiographic leakage due to retinal vein occlusions. Images were matched automatically. We detected those pixels with a high increment in gray level within the closest area to the foveal center. Binary images displaying leakage were obtained. The procedure was checked against two observers' agreement. Twenty-one angiographic studies were collected. Two images of each sequence were selected for digitalization. Numerical descriptors of the leakage were proposed and quantification plots were designed for each pair of images. Interobserver concordance ranged between 82 and 98% when manually…
Accuracy of delivered versus preset minute ventilation of portable emergency ventilators.
1989
The accuracy of delivered minute volume (VE) ventilation of portable emergency ventilators (PEV) was evaluated. Five PEV from three manufacturers were adapted to an artificial lung for varying compliance and resistance. Each PEV was tested in the "no airmix" (pure oxygen) and "airmix" (approximately 60% oxygen) setting at different frequencies and VE. Measurement of delivered VE (VEdel) was made using a pneumotachograph and digital integration of the flow values greater than 1 min (maximal error +/- 2%). Maximal inspiratory pressure (Pinsp) was measured with a transducer. Two PEV from one manufacturer produced severe hyperventilation when used at low VE (i.e., in children). Two other PEV fr…
In vitro antifungal properties of mouthrinses containing antimicrobial agents
1997
The purpose of this study was to investigate the in vitro antifungal properties of seven commercial mouthrinses containing antimicrobial agents. These included cetylpyridinium chloride (CPC), chlorhexidine digluconate (CHX), hexetidine (HEX), sanguinarine (SNG), and triclosan (TRN). The minimum fungicidal concentration (MFC) against six species of yeasts was determined by a broth macrodilution method. The kill-time of mouthrinses at half the concentration of the commercial formulations was also determined. MFCs were achieved with each mouthrinse, except the SNG-containing mouthrinse, against all the organisms being tested. However, the CPC-containing mouthrinse appeared more active than the…
Evaluación de los aspectos formales de las revistas pediátricas españolas
2007
Introducción: La normalización de las revistas científicas es impresscindible para la transmisión correcta del conocimiento, pues garantiza la universalidad y reproducibilidad de las investigaciones. El objetivo de este trabajo es realizar una evaluación de los aspectos formales de las revistas pediátricas españolas. Material y métodos: En el año 2005 se estudiaron las características formales de las revistas pediátricas españolas, en particular, y de las revistas biomédicas españolas, en general. Se implementó un formulario, utilizado para la selección de las revistas que forman parte de la cobertura de la base de datos del Índice Médico Español (IME), que evaluaba 64 características difer…
Neuron-specific enolase--a serum marker for malignant melanoma.
1989
Diffusion in slice preparations bathed in unstirred solutions
1987
A diffusion model is described here, which allows for the estimations of drug concentration changes in porous media, such as in slice tissues of the central nervous system (CNS) bathed in unstirred solutions following abrupt changes of drug concentration. This model may be used for the interpretation of data obtained in neuropharmacological studies if (i) the diffusion coefficient of the molecules under investigation is constant within the excised tissue, (ii) drug molecules are diffusing only in the extracellular space (ECS) and are not bound by the tissue, (iii) drug molecules diffuse mainly within one dimension, (iv) the drug concentration in the bath is changed within 5 s, and (v) the b…
Membrane Protein Subunit Fractionation by Means of Inverse Pore Gradient Elution Polyacrylamide Gel Electrophoresis
1996
We report here the preparative scale isolation of the four subunits of the nicotinic acetylcholine receptor (nAChR) applying short inverse pore gradient SDS gels on an elution-PAGE apparatus. The nAChR subunits are of similar molecular weights (alpha, 50.2 kDa; beta, 53.7 kDa; gamma, 56.3 kDa; delta, 57.6 kDa) and isoelectric point (approx 5.5) and share the typical properties of amphiphatic membrane proteins that are difficult to separate by chromatographic procedures. Preparative PAGE, which has proved to be the method of choice for nAChR-subunit fractionation, however, is time-consuming and achieves only moderate resolutions yielding dilute fractions. We present here the fractionation of…
[RIU project: perceived changes by health agents and professionals after a health intervention in an urban area of socioeconomic disadvantage].
2013
Resumen Objetivo Describir los cambios percibidos por la población y los profesionales en relación con la salud y el uso de servicios tras la intervención RIU con agentes comunitarios en un barrio vulnerable. Diseño Estudio descriptivo cualitativo con entrevistas individuales y grupales y observación participante de octubre de 2008 a julio de 2009. Emplazamiento Barrio Raval (Algemesí-Valencia). Participantes Selección por muestreo opinático de 7 mujeres agentes de salud, todas las que finalizaron la intervención, y 10 profesionales implicados en la misma. Método Con las mujeres se mantuvo una entrevista grupal a los 6 meses, y una entrevista grupal y 7 individuales a los 9 meses de interve…
Quantitative analysis of mixtures of metal-carbonyl complexes by Fourier-transform infrared spectroscopy: application to the simultaneous double immu…
1996
Abstract The feasibility of a double immunoassay of haptens by the nonisotopic carbonyl metalloimmunoassay (CMIA) method is demonstrated. Three different pairings of antiepileptic medications from the groups carbamazepine, diphenylhydantoin, and phenobarbital (for each of which a mono-CMIA is already available) were assayed by double CMIA. The assay method employs as tracers metal–carbonyl complexes that give very strong signals in the range of 1850–2200 cm −1 in the infrared spectrum, permitting quantitative analysis by Fourier-transform infrared spectroscopy. The fact that the signals are individually assignable and of comparable intensity permits quantitative analysis of mixtures of two …