Search results for "Excimer"

showing 10 items of 82 documents

Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…

2012

AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…

AdultCorneal Wavefront AberrationDistance visual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalProsthesis DesignContrast SensitivityYoung AdultCellular and Molecular NeuroscienceLens Implantation IntraocularMyopiaHumansContrast (vision)MedicineIn patientAdaptive opticsSimulationmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryAblationeye diseasesSensory SystemsOphthalmologySpherical aberrationHyperopiaOftalmologíaOptometryLasers Excimersense organsbusinessBritish Journal of Ophthalmology
researchProduct

Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses

2011

PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…

AdultCorneal Wavefront AberrationDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituVisual AcuityArtificial Lens Implant MigrationRefraction OcularYoung AdultPostoperative ComplicationsHumansMedicineContrast (vision)media_commonLenses Intraocularbusiness.industryLASIKeye diseasesOphthalmologySpherical aberrationHyperopiaTilt (optics)Intraocular lensesDecreased Visual AcuityOftalmologíaOptometryLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Refractive Surgery
researchProduct

Changes in Tear Protein Pattern after Photorefractive Keratectomy

2003

PURPOSE. Changes in tear protein composition of patients who underwent photorefractive keratectomy (PRK) were analyzed. METHODS. Tear samples were obtained from 23 eyes of 23 patients immediately before PRK and on the fourth postoperative day with glass capillaries. Tear proteins were separated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Digital image analysis and evaluation of the densitometric data of the electrophoretic separations were done with BioDoc-Analyze. RESULTS. Analysis of discriminance found a significant difference in the protein patterns (p<0.001). This type of analysis of the electrophoretic densitographs uses all peak information simultaneously. A signifi…

AdultImmunoglobulin APathologymedicine.medical_specialtymedicine.medical_treatmentEye diseaseLacrimal glandPhotorefractive KeratectomyCornea03 medical and health scienceschemistry.chemical_compound0302 clinical medicineCorneaOphthalmologyHumansMedicinePostoperative PeriodEye ProteinsGel electrophoresisbiologybusiness.industryLactoferrinLacrimal ApparatusGeneral MedicineMiddle Agedmedicine.diseaseeye diseasesPhotorefractive keratectomyOphthalmologymedicine.anatomical_structurechemistryTears030221 ophthalmology & optometrybiology.proteinElectrophoresis Polyacrylamide GelLasers Excimersense organsLysozymebusiness030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Intraocular pressure after excimer laser myopic refractive surgery

2001

The aim of this study was to determine whether intraocular pressure (IOP), as measured by Goldmann applanation or non-contact tonometry, shows systematic changes in patients who have undergone photorefractive keratectomy (PRK) or laser in situ keratomileusis (LASIK). IOP was measured by central Goldmann and non-contact tonometry in 54 patients pre and post-PRK, and in 43 patients pre- and post-LASIK. An interval of 12 months was allowed after surgery. Patients were selected to have one of four specific initial values of refractive error (-2.5, -5.0, -7.5 and -10.0 D). Fellow unoperated eyes were used as controls. A paired Student's t-test and a one-way ANOVA test were used for statistical a…

AdultMaleIntraocular pressuremedicine.medical_specialtyRefractive errorgenetic structuresmedicine.medical_treatmentEye diseaseKeratomileusis Laser In SituContext (language use)KeratomileusisPhotorefractive KeratectomySensitivity and SpecificityTonometry OcularRefractive surgeryOphthalmologyMyopiamedicineHumansIntraocular PressureAnalysis of Variancebusiness.industryLASIKmedicine.diseaseeye diseasesSensory SystemsPhotorefractive keratectomySurgeryOphthalmologyFemaleLasers Excimersense organsbusinessOptometryOphthalmic and Physiological Optics
researchProduct

Mass spectroscopic analysis of excimer laser ablated material from human corneal tissue.

1988

The clinical feasibility of photorefractive keratectomy depends on the surface structure of the ablated cornea. Two factors that influence the remodeled surface are the homogeneity of the energy distribution and the properties of the laser source (energy and wavelength). Currently, the homogeneity of the beam is difficult to control. The second factor, laser source properties, was the focus of this study. We investigated the effect of laser wavelength and energy by analyzing the reaction products of photoablation. We monitored the fragments produced by UV-laser ablation of human corneas using mass spectroscopy in the range of 0 to 100 atomic mass units. At 248 nm (KrF), average photon energ…

AdultMaleMaterials sciencemedicine.medical_treatmentPhysics::Medical PhysicsAnalytical chemistryPhotoablationPhoton energyMass spectrometryFluenceMass Spectrometrylaw.inventionCorneaOpticslawIonizationmedicineCadaverHumansAgedExcimer laserbusiness.industryAtomic mass unitMiddle AgedLaserSensory SystemsOphthalmologySurgeryFemaleLaser TherapybusinessJournal of cataract and refractive surgery
researchProduct

Optical and Visual Simulation of Standard and Modified Spherical Aberration Implantable Collamer Lens Post Myopic LASIK Surgery

2013

To evaluate the visual quality achieved in patients undergoing standard or modified implantable Collamer lens (ICL) to correct residual myopic error after laser-assisted in situ keratomileusis (LASIK) surgery.The adaptive optics visual simulator was used to simulate LASIK surgery of moderate and high myopia with a myopic regression corrected by a standard and modified ICL. Visual acuity (VA) and contrast sensitivity (CS) were measured in 14 subjects at 3- and 4.5-mm pupil. Point spread function and simulated retinal images were calculated.Comparing LASIK plus standard ICL and LASIK plus modified ICL simulations, for moderate myopia, VA improvement was less than 1 line in all VA contrasts an…

AdultMaleOptics and PhotonicsPhakic Intraocular Lensesmedicine.medical_specialtyCorneal Wavefront AberrationAdolescentgenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisPhakic intraocular lensContrast SensitivityYoung AdultLens Implantation IntraocularAberrometryMyopiamedicineHumansIn patientPostoperative PeriodImplantable collamer lensbusiness.industryAberrometryLASIKGeneral Medicineeye diseasesSurgeryOphthalmologySpherical aberrationOptometryFemaleLasers ExcimerbusinessEuropean Journal of Ophthalmology
researchProduct

Image quality and visual performance in the peripheral visual field following photorefractive keratectomy.

2002

ABSTRACT PURPOSE: A theoretical and experimental study was performed to assess the possible effects of photorefractive keratectomy (PRK) on retinal image quality and thresholds in the peripheral visual field. METHODS: Simple optical calculations suggest that although the quality of the retinal image at the fovea of the postoperative PRK eye may be comparable to that in an emmetropic eye, images in the peripheral field may be markedly worse, since peripheral ray bundles may pass partly through ablated and partly through unablated cornea, giving a simultaneous-vision bifocal effect. This would be expected to create an annular zone of confusion, so that light from two different directions in o…

AdultMaleOptics and Photonicsgenetic structuresmedicine.medical_treatmentVisual AcuityEmmetropiaPhotorefractive Keratectomychemistry.chemical_compoundCorneaMyopiaHumansMedicineVision OcularRetinabusiness.industryRetinaleye diseasesPhotorefractive keratectomyVisual fieldOphthalmologymedicine.anatomical_structureMeridian (perimetry visual field)chemistrySensory ThresholdsVisual Field TestsOptometryFemaleLasers ExcimerSurgerysense organsVisual FieldsbusinessPhotopic vision
researchProduct

Influence of Refraction on Tonometric Readings After Photorefractive Keratectomy and Laser Assisted In Situ Keratomileusis

2000

PURPOSE To determine the decrease of Goldmann tonometry after photorefractive keratectomy (PRK) and laser assisted in situ keratomileusis (LASIK) according to refraction prior to surgery. METHODS Prospective simultaneous comparative case series of 53 myopic eyes (53 patients) that underwent PRK and 50 (50 patients) that underwent LASIK using the Summit Excimed SVS plus (Summit Technology, Inc., Walthan, MA, U.S.A.). PRK and LASIK were subdivided by refractive error into two subgroups of more than or less than -5 diopters (D). Central tonometric readings were taken prior to surgery and 12 months after surgery. RESULTS In LASIK and PRK subgroups of more than -5 D, 85.7% (24) and 69.6% (24), r…

AdultMaleRefractive errormedicine.medical_specialtyAdolescentgenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituKeratomileusisRefraction OcularPhotorefractive KeratectomyTonometry OcularOphthalmologyMyopiaHumansMedicinePostoperative PeriodProspective StudiesIntraocular PressureDioptrebusiness.industryReproducibility of ResultsLASIKGlaucomaMiddle Agedmedicine.diseaseLaser assistedRefractioneye diseasesPhotorefractive keratectomyGoldmann tonometryOphthalmologyFemaleLasers Excimersense organsbusinessCornea
researchProduct

Reproducibility of digital image analysis for measuring corneal haze after myopic photorefractive keratectomy.

1997

Purpose To evaluate the usefulness of digital image analysis for quantifying corneal haze by determining the reproducibility of its measurements at the corneal plane. Methods In a prospective study, 20 randomly selected eyes that had undergone myopic photorefractive keratectomy were photographed focusing the slit beam on their anterior corneal surface. Each photograph was examined using computer image analysis techniques that detect the edge of the reticular pattern of the image. Quantification of the difference between two areas, treated and adjacent untreated cornea, each containing 3,750 pixels with a resolution of 256 gray levels, was performed. Intra-analyzer variation was determined b…

AdultMaleRefractive errormedicine.medical_specialtyHazeMaterials sciencegenetic structuresCoefficient of variationmedicine.medical_treatmentImage processingPhotorefractive KeratectomyCorneaOpticsPostoperative ComplicationsCorneaOphthalmologymedicineImage Processing Computer-AssistedMyopiaHumansProspective StudiesReproducibilityCorneal Hazebusiness.industryReproducibility of ResultsMiddle Agedmedicine.diseaseeye diseasesPhotorefractive keratectomyOphthalmologymedicine.anatomical_structureFemaleLasers Excimersense organsbusinessAmerican journal of ophthalmology
researchProduct

Direct Objective Quantification of Corneal Haze after Excimer Laser Photorefractive Keratectomy for High Myopia

1996

Purpose: The purpose of the study is to measure regional distribution differences in corneal haze after excimer laser photorefractive keratectomy for high myopia. Methods: The authors developed computerized gradient edge detectors with which were analyzed digitized anterior slit-lamp photographs of 40 eyes, an average of 21.0 plus or minus 14.5 weeks after photorefractive keratectomy for high myopia (−6 to −22 diopters). A treated area and an adjacent untreated area on the anterior corneal surface, each containing six regions, were quantified, and the difference was correlated with various parameters. Results: Mean differences between scarred and clear areas for haze grade 0.5, 1.0, 2.0, 3.…

AdultMaleRefractive errormedicine.medical_specialtyHazegenetic structuresmedicine.medical_treatmentExcimerPhotorefractive KeratectomyCorneaCorneal OpacityOphthalmologyCorneaImage Processing Computer-AssistedMyopiamedicineHumansDioptreCorneal Hazebusiness.industryMiddle Agedmedicine.diseaseeye diseasesPhotorefractive keratectomyOphthalmologymedicine.anatomical_structureFemaleLasers Excimersense organsbusinessFollow-Up StudiesAblation zoneOphthalmology
researchProduct