Search results for "Extraction"

showing 10 items of 2072 documents

Simultaneous quantification of 18 different phytocannabinoids in serum using a highly sensitive liquid chromatography-tandem mass spectrometry (LC-MS…

2021

Abstract The potential therapeutic effects of various phytocannabinoids and the availability of multiple cannabis-based medicines make it desirable to have an analytical method that simultaneously quantifies a wide range of cannabinoids in blood, beyond delta-9-tetrahydrocannabinol and its metabolites. A liquid chromatography tandem mass spectrometry (LC-MS/MS) method for quantification of 18 phytocannabinoids and cannabinoid metabolites in serum was developed and validated. The method enables simultaneous detection of delta-9-tetrahydrocannabinol, cannabidiol, cannabinol, cannabigerol, cannabichromene, cannabicyclol, tetrahydrocannabivarin and cannabidivarin and their acidic precursors tet…

Detection limitChromatographyCannabigerol010401 analytical chemistryClinical BiochemistryCell BiologyGeneral MedicineTetrahydrocannabivarin030226 pharmacology & pharmacy01 natural sciencesBiochemistryCannabicyclol0104 chemical sciencesAnalytical Chemistry03 medical and health scienceschemistry.chemical_compoundCannabichromene0302 clinical medicinechemistryLiquid chromatography–mass spectrometrymedicineCannabinolSolid phase extractionmedicine.drugJournal of chromatography. B, Analytical technologies in the biomedical and life sciences
researchProduct

Automatic in-tube SPME and fast liquid chromatography: A cost-effective method for the estimation of dibuthyl and di-2-ethylhexyl phthalates in envir…

2007

A 80-cm length commercially available capillary coated with 95% polydimethylsiloxane and 5% polydiphenylsiloxane (TBR-5) was employed to carry out on-line extraction and preconcentration of dibuthyl phthalate (DBP) and di-2-ethylhexyl phthalate (DEHP) in the chromatographic system. The coated capillary was placed between the sample injection loop and the injection needle of an autosampler. Variables affecting the automatic in-tube solid-phase microextraction (SPME) were optimized. A Genesis C(18) (5 cm x 4.6 mm i.d., 4 microm particle size) was employed as analytical column. The achieved limits of detection by use of diode array detection were 1 and 2.5 microg L(-1), respectively. The propo…

Detection limitChromatographyCapillary actionCost-Benefit AnalysisCoefficient of variationExtraction (chemistry)PhthalateAnalytical chemistryReproducibility of ResultsSolid-phase microextractionSensitivity and SpecificityBiochemistryDibutyl PhthalateAnalytical Chemistrychemistry.chemical_compoundchemistryDiethylhexyl PhthalateEnvironmental ChemistrySample preparationParticle sizeWater Pollutants ChemicalSpectroscopyAnalytica Chimica Acta
researchProduct

Analysis of post-harvest fungicides by micellar electrokinetic chromatography.

2001

A method based on solid-phase extraction (SPE) and micellar electrokinetic chromatography (MEKC) was developed for the simultaneous determination of carbendazim, imazalil, methylthiophanate, O-phenylphenol, prochloraz, procimidone, thiabendazole and triadimefon residues in grape, lettuce, orange and tomato. Selectivity and resolution were studied changing the pH and the concentration of the buffer, the type and concentration of surfactant and the methanol content in the mobile phase. A buffer consisting of 4 mM borate with 75 mM sodium cholate (pH 9.2) gave the best results. The recoveries of the fungicides in spiked fruit and vegetable samples ranged from 30 to 105%, and the limits of dete…

Detection limitChromatographyCarbendazimOrganic ChemistryReproducibility of ResultsSodium Dodecyl SulfateGeneral MedicineBuffersSodium CholateBiochemistryMicellar electrokinetic chromatographyAnalytical ChemistryFungicides IndustrialFungicidechemistry.chemical_compoundSurface-Active AgentsTriadimefonchemistryFruitSample preparationSolid phase extractionSodium CholateChromatography Micellar Electrokinetic CapillaryJournal of chromatography. A
researchProduct

Determination of PAHs in airborne particles by accelerated solvent extraction and large-volume injection-gas chromatography-mass spectrometry.

2006

Abstract A sensitive and automated method is presented for the determination of polycyclic aromatic hydrocarbons (PAHs) in airborne particulate matter. The procedure includes extraction of PM10-bound PAHs by accelerated solvent extraction (ASE) followed by gel permeation chromatography (GPC) clean-up, and large-volume programmable temperature vaporizer (PTV–LV) injection coupled to GC–MS. The limit of detection (LOD) of the whole method, based on a signal-to-noise ratio (S/N) of 3:1, ranged from 0.26 pg m−3 to 3 pg m−3 when air volumes of 760 m3 are collected. The hexane–acetone mixture (1:1, v/v) gave the best recoveries when ASE parameters were fixed at 125 °C, 1500 psi, and a total time …

Detection limitChromatographyCentral composite designChemistryExtraction (chemistry)Analytical chemistryAnalytical ChemistryGel permeation chromatographymedia_common.cataloged_instanceSample preparationGas chromatographyGas chromatography–mass spectrometryEuropean unionmedia_common
researchProduct

Sensitive determination of free benzophenone-3 in human urine samples based on an ionic liquid as extractant phase in single-drop microextraction pri…

2007

Abstract Benzophenone-3 (BZ3), one of the compounds most commonly used as UV filter in cosmetic products, can be absorbed through the skin into the human body, since it can be found at trace levels in urine from users of cosmetic products that contain BZ3. Moreover, different undesirable effects have been attributed to this compound. Thus, sensitive analytical methods to monitor urinary excretion of this compound should be developed. This paper presents a selective and sensitive methodology for BZ3 determination at ultratrace levels in human urine samples. The methodology is based on a novel microextraction technique, known as single-drop microextraction (SDME). An ionic liquid (IL) has bee…

Detection limitChromatographyCentral composite designOrganic ChemistryAnalytical chemistryTemperatureIonic LiquidsGeneral MedicineBiochemistryHigh-performance liquid chromatographyChemistry Techniques AnalyticalAnalytical Chemistrychemistry.chemical_compoundBenzophenoneschemistryIonic strengthLiquid–liquid extractionStandard additionIonic liquidHumansSample preparationChromatography LiquidJournal of chromatography. A
researchProduct

On-line preconcentration strategies for analyzing pesticides in fruits and vegetables by micellar electrokinetic chromatography.

2007

Five pesticides (fludioxonil, procymidone, pyriproxyfen, dinoseb and carbendazim) were separated in reversed migration micellar electrokinetic chromatography (RM-MEKC) using 20 mmol l(-1) phosphate buffer at pH 2.3, containing 25 mmol l(-1) sodium dodecylsulfate and 10% methanol. Three on-line concentration strategies, sweeping (SW), normal stacking with reversed migration and a water plug (SRW) and stacking with reverse migration and removal of sample matrix using polarity switching (SRMM), were compared. About 10-, 30- and 50-fold increases in detection sensitivity, compared with standard hydrodynamic injection (5 s at 0.5 psi), were observed with SW, SRW and SRMM, respectively. Limits of…

Detection limitChromatographyChemistryCarbendazimOrganic ChemistryAnalytic Sample Preparation MethodsElectrophoresis CapillaryGeneral MedicineBiochemistryOnline SystemsMicellar electrokinetic chromatographyAnalytical ChemistryFungicides Industrialchemistry.chemical_compoundElectrophoresisFruitDinosebVegetablesSample preparationSolid phase extractionProcymidonePesticidesFood AnalysisChromatography Micellar Electrokinetic CapillaryJournal of chromatography. A
researchProduct

Improved Solid Phase Extraction Procedure for Assay of Cephalosporins in Human Urine Samples

1998

Abstract Solid phase extraction technique has been evaluated for the treatment of urine samples in the analysis of cephalosporins before injection into an HP-Hypersil ODS-C18 column. Cephalexin, cefotaxime, cefazolin, cefuroxime, and cefoxitin were tested with seven different reversed-phase extraction column cartridges and the obtained urine extracts were not clean. However, 3M Empore extraction disk cartridges packed with octadecyl (C18) bonded silica provided clean extracts with a single extraction. The recoveries of the five cephalosporins ranged from 56 to 60 % in the 1.25–500 g/mL concentration range. The assay was accurate, precise, and adequate for testing the drug content in urine s…

Detection limitChromatographyChemistryClinical BiochemistryExtraction (chemistry)Pharmaceutical ScienceUrineBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryCefalexinmedicineSolid phase extractionCefuroximeAntibacterial agentmedicine.drugJournal of Liquid Chromatography & Related Technologies
researchProduct

Effect of the shampoo Ultra Clean on drug concentrations in human hair

2000

The influence of the special shampoo Ultra Clean (Zydot Unlimited, Tulsa, Oklahoma) on the results of hair analyses was investigated. Hair samples from persons (n = 14) with a known history of drug abuse were collected at autopsy. The hair samples were divided into separate strands which were analyzed both after washing with Ultra Clean and without treatment. Hair analyses were performed by methanol extraction under sonication, purification by solid phase extraction and GC/MS in SIM mode according to routine procedures for tetrahydrocannabinol (THC), cocaine, amphetamine, methylenedioxyamphetamine (MDA), methylenedioxymethamphetamine (MDMA), methylenedioxyethylamphetamine (MDE), heroin, 6-m…

Detection limitChromatographyChemistryCodeineHair PreparationsMDMAForensic MedicineDihydrocodeineShampooPathology and Forensic MedicineSubstance Abuse DetectionmedicineMorphineHumansSolid phase extractionTetrahydrocannabinolHairmedicine.drugInternational Journal of Legal Medicine
researchProduct

On-line in-tube solid phase microextraction-capillary liquid chromatography method for monitoring degradation products of di-(2-ethylhexyl) phthalate…

2014

Abstract The main di-(2-ethylhexyl) phthalate (DEHP) degradation products, (2-ethylhexyl) phthalate (MEHP), diethyl phthalate (DEP) and dibutyl phthalate (DBP), have been tested. The proposed cost-effective method combines on-line, in-tube solid-phase micro extraction (IT-SPME) in in-valve configuration and capillary liquid chromatography with UV diode array detection (Cap-LC-DAD). Acidification of the samples at pH 3 improved markedly the estimation of MEHP. Aliquots of 4 mL of acidified water samples were directly processed. After sample loading, the analytes were desorbed with the mobile-phase and transferred to the monolithic capillary column. Satisfactory linearity and precision, absen…

Detection limitChromatographyChemistryDibutyl phthalateCapillary actionOrganic ChemistryExtraction (chemistry)Phthalic AcidsPhthalateGeneral MedicineSolid-phase microextractionDiethyl phthalateBiochemistryDibutyl PhthalateAnalytical Chemistrychemistry.chemical_compoundPlasticizersDiethylhexyl PhthalateSample preparationSolid Phase MicroextractionWater Pollutants ChemicalChromatography LiquidJournal of Chromatography A
researchProduct

A solid-phase extraction and size-exclusion liquid chromatographic method for polyethylene glycol 25 p-aminobenzoic acid determination in urine: Vali…

2007

No previous publications about percutaneous absorption of polyethylene glycol 25 p-aminobenzoic acid (PEG-25 PABA) have been found in the literature and the expected levels to be found in human urine after sunscreens use are unknown. The method proposed here is suitable to determine PEG-25 PABA in the urine of sunscreens users in order to carry out studies on body accumulation/excretion. It is based on solid-phase extraction (SPE) with size-exclusion liquid chromatography determination. Solid-phase extraction allows the analyte to be retained and subsequently eluted for a clean-up, using a silica-based cartridge. The size-exclusion liquid chromatography of the eluted allows the rest of matr…

Detection limitChromatographyChemistryElutionExtraction (chemistry)Fluorescence spectrometryReproducibility of ResultsUrineBiochemistryPolyethylene GlycolsAnalytical ChemistryMatrix (chemical analysis)ExcretionSpectrometry FluorescenceChromatography GelHumansEnvironmental ChemistrySolid phase extraction4-Aminobenzoic AcidSunscreening AgentsSpectroscopyAnalytica Chimica Acta
researchProduct