Search results for "Eye"
showing 10 items of 2511 documents
Femtosecond laser for residual refractive error correction after refractive lens exchange with multifocal intraocular lens implantation.
2008
Purpose To assess visual and refractive outcomes of femtosecond laser for residual refractive error correction after refractive lens exchange (RLE) with multifocal intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Methods Fifty-three eyes of 31 consecutive patients were submitted to femtosecond laser surgery after RLE with multifocal IOL implantation. Patients showed an average manifest refractive error (D) of M , 0.200 ± 0.490; J 0 , −0.051 ± 0.532; and J 45 , −0.007 ± 0.371. Visual acuity (VA) was measured at distance and near vision before and six months after the surgery. Results At six months after surgery, mean …
Laser e Dry Eye syndrome
2014
Transcranial direct current stimulation over left and right DLPFC: Lateralized effects on planning performance and related eye movements.
2014
Left and right dorsolateral prefrontal cortex (dlPFC) were recently found to be differentially affected by unilateral continuous theta-burst stimulation, reflected in an oppositional alteration of initial thinking time (ITT) in the Tower of London planning task. Here, we further explored this finding using bilateral transcranial direct current stimulation (tDCS) and simultaneous tracking of eye movements. Results revealed a decrease in ITT during concurrent cathodal tDCS of left dlPFC and anodal tDCS of right dlPFC. Eye-movement analyses showed that this facilitating tDCS effect was associated with the actual planning phase, thus reflecting a planning-specific impact of stimulation. For the…
The influence of storage method on the transparency of pig crystalline lens
2019
Este artículo se ha publicado de forma definitiva en: http://www.scielo.br/pdf/abo/v82n1/0004-2749-abo-82-01-0056.pdf Purpose: The porcine eye is frequently used as a research model. This paper analyzes the effect of different storage methods on the transparency of pig crystalline lens. Methods: A spectral transmission curve (from 220 to 780 nm) for the crystalline lens was determined experimentally after storage in different conditions: saline solution, formalin, castor oil, and freezing at -80°C. The total transmission in the visible spectrum, which was used as an index of transparency, was calculated from these curves. For comparative purposes, fresh lenses were evaluated and used as con…
Agreement of predicted intraocular lens power using swept-source optical coherence tomography and partial coherence interferometry
2021
PURPOSE To analyze the agreement of the predicted intraocular lens (IOL) power obtained with ANTERION, IOLMaster 700 and Pentacam AXL biometers. METHODS We calculated the monofocal and trifocal IOL power using the SRK/T, Haigis, Barrett Universal II and Hoffer Q formulas for 106 eyes. IOL power agreement between devices was evaluated using the Bland-Altman method. RESULTS We found significant differences between biometers comparisons (p 0.05), with the same outcomes for medium- and long-eyes. No significant differences were found using the SRK/T, Haigis, or Hoffer Q formulas for short-eyes (p > 0.1). However, Barrett Universal II formula produced significant differences (p < 0.05) and thes…
A rapid method for measuring intraocular lens power in vitro with a focimeter.
2015
In this paper we describe a new method for measuring the intraocular lens (IOL) power using a focimeter, a negative ophthalmic lens and a saline solution (0.9% NaCl). To test this we measured the power of 58 different IOLs and we compared them with the power stated by the manufacturer. Despite the limitations, the results show a good correlation.
Impact of contact lens material and design on the ocular surface.
2018
BACKGROUND: To evaluate the impact on the ocular surface of a daily disposable hydrogel contact lens with high water content compared with two silicone hydrogel daily disposable lenses of lower water content. METHODS: The hydrogel lens assessed was made from nesofilcon A and the silicone hydrogel lenses were made of delefilcon A and stenfilcon A. Contact lens thickness was measured to assess material stability during daily wear, and ocular surface parameters such as tear film osmolarity, tear meniscus area and central corneal thickness were also assessed. Optical quality was analysed for all cases by means of wavefront aberrometry. RESULTS: The nesofilcon A was shown to be the thinnest lens…
La figura del Che
2007
Rebecca abused: a comparative analysis of censorship in the novel and its film adaptation
2019
En 1938, la escritora inglesa Daphne du Maurier (1907-1989) completaba la escritura de Rebecca. En 1940, se estrenaba la adaptación cinematográfica, dirigida por Alfred Hitchcock. La escasa estima que sentía Hitchcock por la novela original, así como los fundamentos del puritano Código Hays (1930), hicieron que el guion original tuviera que ser enmendado. Paralelamente, en 1938, se imponía en España la Ley de Prensa, que pondría al servicio del régimen franquista toda la producción literaria. Sin embargo, la censura franquista dio carta blanca a Rebeca (novela y adaptación cinematográfica). En este trabajo analizamos los comportamientos censores de ambos códigos, coetáneos y similares en cu…
Antonii Gomezii ... Ad leges tauri commentarium absolutissimum
1780
Frisos, vinyetes i caplletres ornades Sign.: []2, A-Z, Aa-Zz, Aaa-Rrr6, Sss-Ttt4 Port. a 2 tintes. - Text a 2 col. - Notes a peu de p. - Reclams. - Errates de Pag.