Search results for "Eye"

showing 10 items of 2511 documents

Colorimetric gas detection by the varying thickness of a thin film of ultrasmall PTSA-coated TiO2 nanoparticles on a Si substrate

2017

Financial support from the Estonian Research Council (IUT2-25, PUT170, PUT1096, PUT748, PUTJD680), the Estonian Centre of Excellence in Research Projects “Advanced materials and high-technology devices for sustainable energetics, sensorics and nanoelectronics” TK141 (2014-2020.4.01.15-0011), “Emerging orders in quantum and nanomaterials” TK134 and the Development Fund of the University of Tartu, are all gratefully acknowledged.

Materials scienceSiliconAnalytical chemistryGeneral Physics and Astronomychemistry.chemical_element02 engineering and technologySubstrate (electronics)engineering.material010402 general chemistrylcsh:Chemical technology01 natural scienceslcsh:TechnologyCoating:NATURAL SCIENCES:Physics [Research Subject Categories]General Materials Sciencelcsh:TP1-1185Electrical and Electronic EngineeringThin filmAbsorption (electromagnetic radiation)lcsh:ScienceOptical path lengthbusiness.industrylcsh:Tp-toluenesulfonic acid (PTSA)021001 nanoscience & nanotechnologylcsh:QC1-9990104 chemical scienceschemistryengineeringOptoelectronicslcsh:QNaked eye0210 nano-technologybusinessRefractive indexTiO2 nanoparticlescolorimetric gas sensinglcsh:PhysicsBeilstein Journal of Nanotechnology
researchProduct

Amorphous and crystalline polyetheretherketone: Mechanical properties and tissue reactions during a 3-year follow-up.

2007

The study was aimed to test the mechanical strength, structural stability, and tissue reactions of optically amorphous and crystalline polyetheretherketone (PEEK) plates during a 3-year follow-up in vivo and in vitro. The injection-moulded PEEK plates were implanted to the dorsal subcutis of 12 sheep, which were sacrificed at 6-156 weeks. Thereafter, the plates were subjected to tensile tests, and levels of crystallinity were assessed by differential scanning calorimetry (DSC). Histological evaluation was carried out using the paraffin technique. In vitro properties were examined with the tensile test and DSC at 0-156 weeks. Tissue reactions were mild and fairly similar for the amorphous an…

Materials scienceYield (engineering)PolymersBiomedical EngineeringBiocompatible MaterialsPolyethylene GlycolsBiomaterialsProsthesis ImplantationCrystallinityBenzophenonesDifferential scanning calorimetryTensile StrengthUltimate tensile strengthMaterials TestingPeekAnimalsAnesthesiaComposite materialTensile testingInflammationSheepMetals and AlloysProstheses and ImplantsKetoneseye diseasesInternal FixatorsAmorphous solidEosinophilsCeramics and Compositessense organsElongationFollow-Up StudiesJournal of biomedical materials research. Part A
researchProduct

Calibration of a thermoluminescent dosimeter worn over lead aprons in fluoroscopy guided procedures

2018

Fluoroscopy guided interventional procedures provide remarkable benefits to patients. However, medical staff working near the scattered radiation field may be exposed to high cumulative equivalent doses, thus requiring shielding devices such as lead aprons and thyroid collars. In this situation, it remains an acceptable practice to derive equivalent doses to the eye lenses or other unprotected soft tissues with a dosimeter placed above these protective devices. Nevertheless, the radiation backscattered by the lead shield differs from that generated during dosimeter calibration with a water phantom. In this study, a passive personal thermoluminescent dosimeter (TLD) was modelled by means of …

Materials scienceeye lens doseTLDImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsProtective Clothingfashionbackscatter correction factorCalibrationmedicineDosimetryFluoroscopylead apronWaste Management and DisposalDosimetermedicine.diagnostic_testRadiation Dosimetersbusiness.industryEquivalent dosePublic Health Environmental and Occupational HealthEquipment DesignGeneral MedicinefluoroscopyLeadFluoroscopy030220 oncology & carcinogenesisfashion.garmentCalibrationLead apronThermoluminescent DosimetryThermoluminescent dosimeterbusinessJournal of Radiological Protection
researchProduct

<title>Eye model with controllable lens scattering</title>

2001

A model of human eye for experiments in vision research has been developed using PLZT ceramics. This ``artificial eye{''} allows to simulate light scattering caused by cataract in the eye lens. Light scattering of a composite eye lens of the model depends on the electric field applied to a transparent electrooptic PLZT ceramics plate that is attached directly to the lens. The image degradation in such a model eye at various degrees of scattering is studied observing and recording the contrast of images on the ``retinal plane{''} created by standard test objects with different spatial frequency or by a He-Ne laser source passing a diffractive transparent placed before the eye.

Materials sciencegenetic structuresScatteringbusiness.industrymedia_common.quotation_subjecteye diseasesLight scatteringlaw.inventionLens (optics)medicine.anatomical_structureOpticslawElectric fieldmedicineOptoelectronicsContrast (vision)Human eyesense organsSpatial frequencyCylindrical lensbusinessmedia_commonSPIE Proceedings
researchProduct

Ultraviolet radiation at Mediterranean latitudes and protection efficacy of intraocular lenses.

2011

Summary Purpose After determining the mean intensity of ultraviolet radiation to which the human eye is exposed at Mediterranean latitudes, this data is used to evaluate the efficacy of the ultraviolet filters incorporated into various intraocular lenses. Methods Ultraviolet radiation measured at Mediterranean latitudes was used as a reference for the theoretical calculation of the amount of radiation to which the human eye is exposed. The spectral transmission curve from 290 to 380 nm was measured for 10 IOLs using a UV/VIS Perkins-Elmer Lambda 800 spectrometer. Results At Mediterranean latitudes, at sea level, with a mean annual solar irradiation of 50 j/cm 2 , the human eye receives a qu…

Materials sciencegenetic structuresUltraviolet Raysmedicine.medical_treatmentIntraocular lensRadiationmedicine.disease_causelaw.inventionOpticsRadiation ProtectionlawLens CrystallinemedicineAnimalsHumansIrradiationLenses Intraocularbusiness.industryMediterranean RegionAlbedoeye diseasesLens (optics)OphthalmologyWavelengthmedicine.anatomical_structureSunlightHuman eyesense organsRabbitsbusinessUltravioletJournal francais d'ophtalmologie
researchProduct

Measuring the refractive state of an eye based on the intensity of the retinal reflex

2017

AbstractWhen examining the fundus of the eye with an ophthalmoscope, the intensity of the retinal reflex depends on the refractive state of the eye. In this study, application of this phenomenon for measuring the refractive state of the eye is demonstrated. First, a calibration curve relating the intensity of the retinal reflex and the refractive state was obtained using a model eye. Next, the intensity of the retinal reflex was measured while subjects were viewing a checker-board pattern, the distance of which was varied within the range from 0.17 to 1 m. Further, the relation between the refractive state and the optical power of the stimulus could be determined based on the measured light…

Materials sciencegenetic structuresbusiness.industryCalibration curve05 social sciencesOptical powerRetinaleye diseases050105 experimental psychologyAtomic and Molecular Physics and Optics03 medical and health scienceschemistry.chemical_compoundLight intensity0302 clinical medicineOpticschemistry030221 ophthalmology & optometryReflex0501 psychology and cognitive sciencessense organsbusinessAccommodationJournal of Modern Optics
researchProduct

Influence of the Ce: YAG amount on structure and optical properties of Ce:YAG-PMMA composites for white LED

2016

Ce:YAG-poly(methyl methacrylate) (PMMA) composites were prepared by using a melt compounding method, adding several amounts of Ce:YAG in the range 0.1–5wt.%. The optical properties of the obtained composites and of the composites combined with a blue LED were measured to investigate the effect of the amount of Ce:YAG on the resulting emitted light in view of possible application in white LED manufacture. An increase in Ce:YAG amount caused an increase in the emission and a shift of 15 nm, influencing the white LED performance. The structure and morphology of the composites were studied. The results show that the interaction between the two components, observed by using solid state NMR exper…

Materials sciencegenetic structuresbusiness.industryWhite LEDPolymeric Composites02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnologyPMMA01 natural sciencesInterface InteractionsYAG [Ce]eye diseases0104 chemical sciencesOptoelectronicsComposite materialPhysical and Theoretical Chemistry0210 nano-technologybusiness
researchProduct

OCT applications in contact lens fitting

2022

Optical Coherence Tomography (OCT) is a noninvasive, high-speed, high-resolution imaging technology based in the Michaelson interferometry. A near-infrared light beam is used to register the intensity variations for the light backscattered on each sample layer. Due to the high repeatability on corneal measurements, spectral domain OCT (SD-OCT) is the gold standard when talking about in vivo, non-invasive anterior segment imaging. Changes in the morphology of various ocular surfaces such as the cornea, conjunctiva, limbus or tear film with soft (SCL), rigid, corneal or scleral lens (SL) wear can be described by OCT measurements. For instance, evaluation of the corneoscleral region is essenti…

Materials sciencegenetic structuresmedicine.medical_treatmentlaw.inventionCorneaOptical coherence tomographyScleral lenslawCorneamedicineHumansmedicine.diagnostic_testOrthokeratologyGeneral MedicineRepeatabilityContact Lenses Hydrophiliceye diseasesContact lensLens (optics)OphthalmologyInterferometrymedicine.anatomical_structureTearssense organsConjunctivaTomography Optical CoherenceOptometryBiomedical engineeringContact Lens and Anterior Eye
researchProduct

Teaching of laser medical topics: Latvian experience

2002

Pilot program for Master's studies on Biomedical Optics has been developed and launched at University of Latvia in 1995. The Curriculum contains several basic subjects like Fundamentals of Biomedical Optics, Medical Lightguides, Anatomy and Physiology, Lasers and Non-coherent Light Sources, Optical Instrumentation for Healthcare, Optical Methods for Patient Treatment, Basic Physics, etc. Special English Terminology and Laboratory-Clinical Praxis are also involved, and the Master Theses is the final step for the degree award. Recently a new extensive short course for medical laser users "Lasers and Bio-optics in Medicine" has been prepared in the PowerPoint format and successfully presented …

Medical educationPraxisgenetic structuresbusiness.industrymedia_common.quotation_subjectLatvianMechanical engineeringLasereye diseaseslanguage.human_languagelaw.inventionTerminologylawlanguageMedicinePilot programShort coursesense organsSpecial EnglishbusinessCurriculummedia_commonSPIE Proceedings
researchProduct

Attentional biases toward emotional images in the different episodes of bipolar disorder: an eye-tracking study.

2014

Attentional biases toward emotional information may represent vulnerability and maintenance factors in bipolar disorder (BD). The present experimental study examined the processing of emotional information in BD patients using the eye-tracking technology. Bipolar patients in their different states (euthymia, mania, depression) simultaneously viewed four pictures with different emotional valence (happy, neutral, sad, threatening) for 20 s while their eye movements were monitored. A group of healthy individuals served as the control. The data revealed the following: (i) a decrease in attention to happy images in BD patients in their depressive episodes compared to healthy individuals, and (ii…

Medicina i psicologiaAdultMalemedicine.medical_specialtyBipolar DisorderEye MovementsBipolar disorderEmotionsHappinessAsymptomaticYoung AdultmedicineHumansAttentionBipolar disorderPsychiatryEye Movement MeasurementsBiological PsychiatryDepression (differential diagnoses)Eye trackingDepressive DisorderInformation processingEye movementMiddle Agedmedicine.diseaseCognitive biasCognitive biasesFacial ExpressionPsychiatry and Mental healthCase-Control StudiesEye trackingFemaleSelective attentionmedicine.symptomPsychologyManiaClinical psychologyPsychiatry research
researchProduct