Goldmann Applanation Tonometry Using Sterile Disposable Silicone Tonometer Shields
1996
Abstract Purpose: Placement of a sterile single-use cover over the tonometer tip may be a convenient and safe alternative method to repeated chemical disinfection. This study was undertaken to evaluate the accuracy and performance of Goldmann applanation tonometry using a sterile disposable silicone tonometer shield over the biprism tip. Methods: The same investigator measured intraocular pressure in 120 eyes with and without the shield. The eyes were tested randomly first with either the uncovered or the covered tonometer to control for the possible effects of repeated tonometry influencing measurement differences. Readings were recorded independently in a masked fashion. Results: The intr…
Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Glaucoma Patients and Healthy Subjects
2006
To investigate the agreement in the measurement of intraocular pressure (IOP) obtained by dynamic contour tonometry PASCAL (DCT-PASCAL) and Goldmann applanation tonometry (GAT) in glaucoma eyes and healthy eyes with different central corneal thickness (CCT).Prospective cross-sectional study.In a randomized order, three consecutive IOP measurements were performed on 197 eyes of 107 subjects by one examiner using both DCT-PASCAL and GAT on all eyes. Furthermore, ultrasonic pachymetry was performed. The Spearman correlation coefficient (r) was determined to compare IOP readings between DCT-PASCAL and GAT. Regression-based Bland and Altman analysis was used to evaluate agreement between the ins…
The relationship between central corneal thickness and Goldmann applanation tonometry
2003
The aim of this study was to investigate the relationship between Goldmann applanation tonometry and central corneal thickness in a large sample of healthy eyes.Five hundred eyes of 500 subjects (253 women, 50.6 per cent and 247 men, 49.4 per cent) were analysed in a prospective healthy population study. Mean age of the sample was 31 +/- 8 years. Goldmann applanation tonometry was carried out by one physician. Tonometric values were the mean of three consecutive readings. Subsequently, another physician carried out ultrasonic pachymetry with the DGH 2000 AP ultrasonic pachymeter (DGH Technology Inc, San Diego, USA). Ten measurements were made at the centre of the cornea of each eye. The low…
Processing of auditory stimuli during tonic and phasic periods of REM sleep as revealed by event-related brain potentials
1996
The brain has been reported to be more preoccupied with dreams during phasic than during tonic REM sleep. Whether these periods also differ in terms of the processing of external stimuli was examined. Event-related brain potentials (ERPs) to a frequent standard tone of 1000 Hz (P = 97%) and infrequent deviant tones of 1100 and 2000 Hz (P = 1.5% for each) were recorded (n = 13) during wakefulness and nocturnal sleep. An ERP wave (called REM-P3) resembling a waking P3 wave was larger for the 2000 Hz deviant during tonic than during phasic REM sleep. Also the P210 wave was larger during tonic than during phasic REM sleep. A reliable mismatch negativity component appeared only in wakefulness. I…
Wertheim’s hypothesis on ‘highway hypnosis’: empirical evidence from a study on motorway and conventional road driving
2003
This paper aims to study the phenomenon known as 'highway hypnosis' or 'driving without attention mode', which has been defined as a state showing sleepiness signs and attention slip resulting from driving a motor vehicle for a long period in a highly predictable environment with low event occurrence, this being the case with motorways and very familiar roads [Highway hypnosis: a theoretical analysis. In: Gale, A.G., Brown, I.D., Haslegrave, C.M., Moorhead, I., Taylor, S. (Eds.), Vision in Vehicles-III. Elsevier, North-Holland, pp. 467-472]. According to Wertheim's hypothesis on 'highway hypnosis', long-term driving on motorways and conventional roads, e.g. main roads, secondary roads--impl…
Learning by heart : cardiac cycle reveals an effective time window for learning
2018
Cardiac cycle phase is known to modulate processing of simple sensory information. This effect of the heartbeat on brain function is likely exerted via baroreceptors, the neurons sensitive for changes in blood pressure. From baroreceptors, the signal is conveyed all the way to the forebrain and the medial prefrontal cortex. In the two experiments reported, we examined whether learning, as a more complex form of cognition, can be modulated by the cardiac cycle phase. Human participants ( experiment 1) and rabbits ( experiment 2) were trained in trace eyeblink conditioning while neural activity was recorded. The conditioned stimulus was presented contingently with either the systolic or dias…
Ocular biometric repeatability using a new high-resolution swept-source optical coherence tomographer.
2020
To assess the repeatability of ocular biometric parameters using a high-resolution imaging device.74 healthy right eyes were included in this study. Five-repeated measurements were taken with ANTERION high-resolution swept-source optical coherence tomographer (SS-OCT) to measure: corneal thickness (central and at 2, 4 and 6-mm diameters), aqueous depth (AD), lens thickness (LT), anterior chamber volume (ACV), axial length (AL), and pupil (diameter and position). The intrasubject standard deviation (SWe have not found statistically significant differences between repeated measurements (p 0.05). The mean difference for corneal thickness was between -0.08 and 0.28 μm. For AD and LT was 0.004 …
Prismatic Adaptation as a Novel Tool to Directionally Modulate Motor Cortex Excitability: Evidence From Paired-pulse TMS
2014
Abstract Background The prismatic adaptation (PA) is a visuo-motor procedure that has captured the attention of neuroscientists in the last decades, hence it seems to affect high-order cognition. However, the basic neural processes related to PA and its effects on cortical plasticity are not clear yet. Objective/hypothesis The aim of the present study is to explore whether PA induces a direct effect on the motor cortices (M1) excitability. Methods Fourteen healthy participants were submitted to paired-pulse TMS to measure short-intracortical-inhibition (SICI) and intracortical-facilitation (ICF) on both the left and the right M1, before and after PA, that could induce a leftward or rightwar…
Anxiety and facial self-contacts: possible impact on COVID-19 transmission in dental practice
2021
Abstract Background The purpose was to analyse the associations between dental and trait anxiety, fear of COVID-19 and the duration and frequency of spontaneous hand-to-face contact (self-contact). Methods A cross-sectional design was carried out with 128 adult patients from four dental clinics in Madrid, during the confinement, from March 15 to May 15. The patients’ movements in the waiting room were monitored with Microsoft Kinect Software, also completed the Trait anxiety subscale of the STAI, the COVID-19 Fear and the S-DAI questionnaire. Results Associations were observed between the duration and frequency of facial, mask and eye contact with trait anxiety and dental fear was determine…
Attentional capture by emotional scenes across episodes in bipolar disorder: Evidence from a free-viewing task
2015
We examined whether the initial orienting, subsequent engagement, and overall allocation of attention are determined exogenously (i.e. by the affective valence of the stimulus) or endogenously (i.e. by the participant's mood) in the manic, depressive and euthymic episodes of bipolar disorder (BD). Participants were asked to compare the affective valence of two pictures (happy/threatening/neutral [emotional] vs. neutral [control]) while their eye movements were recorded in a free-viewing task. Results revealed that the initial orienting was exogenously captured by emotional images relative to control images. Importantly, engagement and overall allocation were endogenously captured by threate…