Search results for "Eye"

showing 10 items of 2511 documents

Collagen copolymer posterior chamber phakic intraocular lens supported by the ciliary sulcus to treat myopia: One-year follow-up

2014

Purpose To evaluate the predictability, stability, safety, and efficacy of Visian V4b Implantable Collamer Lens phakic intraocular lens (pIOL) implantation to treat varying degrees of myopia. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, and adverse effects were evaluated 12 months postoperatively. Results The study enrolled 121 eyes (68 patients). The mean spherical equivalent decreased from −8.61 diopters (D) ± 3.41 (SD) (range −18.75 to −2.25 D) preoperatively to −0.18 ± 0.29 D (range −1.25 to 0.50 D) 12 months postoper…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyCiliary sulcusgenetic structuresOne year follow upPolymersVisual AcuityBiocompatible MaterialsPhakic intraocular lensYoung AdultLens Implantation IntraocularOphthalmologyMyopiamedicineHumansProspective StudiesIntraoperative ComplicationsProspective cohort studyDioptreImplantable collamer lensEfficacy indexbusiness.industryCiliary Bodyeye diseasesSensory SystemsPosterior chamber phakic intraocular lensOphthalmologyFemaleSurgeryCollagenbusinessJournal of Cataract and Refractive Surgery
researchProduct

Clinical Impact of a Spontaneous Decentration of a Phakic Refractive Lens

2011

PURPOSE To evaluate the clinical impact and possible causes of a spontaneous decentration of a phakic refractive lens (PRL) implanted in a highly myopic eye, and analyzing the visual, refractive, and aberrometric outcome as well as the possible causes for this phenomenon. METHODS The description of a case of bilateral high myopia corrected by implantation with the phakic intraocular lens (pIOL) PRL (Carl Zeiss Meditec, Germany) is presented and documented. Both eyes had similar anatomical configuration, and therefore, a pIOL (Model 101) with the same size was implanted without any associated intraoperative complication. Clinical outcomes were evaluated during a 3-month follow-up. RESULTS Im…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyDistance visual acuitygenetic structuresVisual AcuityComa (optics)Anatomical configurationRefraction OcularPhakic intraocular lensPostoperative ComplicationsOphthalmologyAberrometryMyopiamedicineHumansbusiness.industryLens SubluxationRefractive lensSubjective refractioneye diseasesOphthalmologySpherical aberrationsense organsbusinessFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation

2009

PURPOSE: To evaluate the relationship between subjective measurements of vault and objective values measured with Visante optical coherence tomography (OCT) in eyes receiving an implantable contact lens (ICL) for myopia correction. DESIGN: Observational cross-sectional study. METHODS: SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. PATIENTS: Four hundred and fifty-two eyes from 246 patients were elected to be implanted with a Visian ICL V4 (STAAR Surgical Inc, Monrovia, California, USA). OBSERVATION PROCEDURES: Subjective and objective measurements of vault after implantation of ICL. MAIN OUTCOME MEASURES: Subjective vault classified in 5 levels assessed using an optical …

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyRefractive errorBiometryAdolescentgenetic structuresEye diseasePhakic intraocular lensVision disorderYoung Adult03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyLens CrystallineMyopiamedicineHumansBody Weights and MeasuresImplantable collamer lensScience & Technologybusiness.industryOutcome measuresMiddle Agedmedicine.diseaseeye diseasesOphthalmologyCross-Sectional StudiesVault (architecture)Implantable Contact Lens030221 ophthalmology & optometryOptometryFemalesense organsmedicine.symptombusinessTomography Optical Coherence030217 neurology & neurosurgeryAmerican Journal of Ophthalmology
researchProduct

Iris-fixated toric phakic intraocular lens for myopic astigmatism

2011

Purpose To evaluate the efficacy, predictability, safety, stability, and complications of the Artiflex toric iris-fixated phakic intraocular lens (pIOL) for myopic astigmatism. Setting Private practice surgery centers, Valencia and Terrassa, Spain. Design Cohort study. Methods At 12 months, refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, complications, pIOL misalignment, and endothelial cell count (ECC) were evaluated. Indices of success and misalignment were calculated using vector analysis. Results The study enrolled 42 eyes in 25 patients aged 21 to 39 years. The mean spherical equivalent decreased from −8.85 diopters (D) ± 2.71 (SD) to −0.37 ± 0.46 D, with …

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyVisual acuitygenetic structuresVisual AcuityIrisAstigmatismRefraction OcularPhakic intraocular lensCohort StudiesMyopic astigmatismYoung AdultPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIris (anatomy)Dioptremedicine.diagnostic_testbusiness.industrySuture TechniquesAstigmatismCorneal TopographyCorneal topographymedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment Outcomemedicine.anatomical_structurePrivate practiceFemaleSurgerymedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

On-eye optical quality of daily disposable contact lenses for different wearing times

2012

Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…

AdultMalePoint spread functionOptics and PhotonicsCorneal Wavefront AberrationTime Factorsgenetic structuresZernike polynomialsVisual AcuityPupillaw.inventionYoung Adultsymbols.namesakeOpticslawOptical transfer functionAberrometryMyopiaHumansDisposable EquipmentMathematicsWavefrontbusiness.industryAberrometryContact Lenses Hydrophiliceye diseasesSensory SystemsLens (optics)OphthalmologysymbolsFemalesense organsSpatial frequencybusinessOptometryOphthalmic and Physiological Optics
researchProduct

MAGAM II – prospective observational multicentre poisons centres study on eye exposures caused by cleaning products

2019

Objective: Local effects on the eye following cleaning product exposures are frequently reported. According to EU chemicals legislation many cleaning products are labelled with Hazard Phrase 318 in...

AdultMalePoison Control CentersTime FactorsAdolescentgenetic structuresInjury controlAccident preventionDetergentsPoison controlToxicologyYoung Adult03 medical and health sciencesEye InjuriesInjury Severity Score0302 clinical medicineGermanyEnvironmental healthHumansMedicineProspective Studies030212 general & internal medicineChemical eye injuryChildAgedAged 80 and overbusiness.industryAge FactorsInfant030208 emergency & critical care medicineGeneral MedicineMiddle AgedCleaning product3. Good healthChild PreschoolFemaleObservational studybusinessProduct identificationClinical Toxicology
researchProduct

Proteomics Differentiate Between Thyroid-Associated Orbitopathy and Dry Eye Syndrome.

2015

PURPOSE: In patients with thyroid-associated orbitopathy (TAO), the dry eye syndrome occurs frequently, and symptoms and signs of both disorders overlap making early and accurate differential diagnosis difficult. A differentiation via specific markers is warranted. METHODS: Tear fluid samples of 120 subjects with TAO, TAO + dry eye, dry eye, and controls were collected. The samples were measured using matrix-assisted laser desorption ionization mass spectrometry. The identified proteins were tested with antibody microarrays. RESULTS: Proteomics identified deregulated proteins in TAO and dry eye. Compared with dry eye, proline-rich protein 1 (PROL1, P = 0.002); uridine diphosphate (UDP)-gluc…

AdultMaleProteomicsmedicine.medical_specialtyAntibody microarrayAdolescentDry Eye SyndromesBiologyGraves' ophthalmopathyDiagnosis DifferentialYoung AdultInternal medicineHeat shock proteinmedicineHumansAgedMiddle Agedmedicine.diseaseGraves OphthalmopathyEndocrinologySpectrometry Mass Matrix-Assisted Laser Desorption-IonizationTearsbiology.proteinTearsDry Eye SyndromesFemaleCystatinAntibodyBiomarkersAnnexin A1Investigative ophthalmologyvisual science
researchProduct

Proteomics of tear fluid in thyroid-associated orbitopathy.

2012

Proteomics and mass spectrometry are useful tools for peptide screening in body fluids. In thyroid-associated orbitopathy (TAO), evidence for lacrimal gland involvement with altered composition of tears has been reported. Our objective was to detect and evaluate potential changes in the proteomic patterns of tear fluid in TAO.Tear fluid was collected from 45 patients with TAO and 15 healthy controls. Tear proteins were analyzed using surface-enhanced laser desorption/ionization time-of-flight mass spectrometry, and peptides were identified using matrix-assisted laser desorption/ionization time-of-flight technology.Peptides with molecular weights 3808 Dalton (Da, p=0.004), 3734 Da (p=0.034),…

AdultMaleProteomicsmedicine.medical_specialtyEndocrinology Diabetes and MetabolismDown-RegulationPeptideLacrimal glandProteomicsMass spectrometryEndocrinologyInternal medicinemedicineHumansEye ProteinsAgedchemistry.chemical_classificationMolecular massThyroidLacrimal ApparatusMiddle AgedUp-RegulationGraves OphthalmopathyMatrix-assisted laser desorption/ionizationmedicine.anatomical_structureEndocrinologychemistrySpectrometry Mass Matrix-Assisted Laser Desorption-IonizationTearsTearsSalivary CystatinsFemaleMuramidasePeptidesbeta 2-MicroglobulinThyroid : official journal of the American Thyroid Association
researchProduct

Some physiological and psychological characteristics of myopic and non-myopic young men.

2009

As a part of a research project on the health and functional capacity of men at different ages a comparison of selected physiological and psychological characteristics of myopic and non-myopic 31–35 year-old men was made. The random sample studied consisted of 31 myopic and 100 non-myopic men. It was found that the body mass index and fat content were lower among the myopic than among the non-myopic. No significant differences were found in the elastic properties of skin, in blood pressure or in haematological assays studied between the groups. With respect to physical performance it was observed that the myopic had a higher aerobic capacity whereas there were no significant differences in …

AdultMalePsychological Testsgenetic structuresAnthropometryFat contentPhysical activityDark AdaptationGeneral MedicineAnthropometryeye diseasesAmplitude of accommodationOphthalmologyCognitionPhysical performanceMyopiaOptometryHumanssense organsPsychologyBody mass indexVision OcularDemographyActa ophthalmologica. Supplement
researchProduct

Estimation of the dimensionality of sleep-EEG data in schizophrenics

1993

Deterministic chaos could be regarded as a healthy flexibility of the human brain necessary for correct neuronal operations. Several investigations have demonstrated that in healthy subjects the dimensionality of REM sleep is much higher than that of slow wave sleep (SWS). We investigated the sleep-EEG of schizophrenic patients with methods from nonlinear system theory in order to estimate the dynamic properties of CNS. We hypothesized that schizophrenics would reveal alterations of their dynamic EEG features indicating impaired information processing. In 11 schizophrenic patients, the EEG's dimensionality during sleep stages II and REM was reduced. We suggest that such lower dimensional ch…

AdultMalePsychosisPolysomnographymedia_common.quotation_subjectRapid eye movement sleepSleep REMElectroencephalographyMental ProcessesReaction TimemedicineHumansPharmacology (medical)Biological PsychiatrySlow-wave sleepmedia_commonCerebral CortexPsychiatric Status Rating ScalesSleep Stagesmedicine.diagnostic_testSignal Processing Computer-AssistedGeneral MedicineHuman brainmedicine.diseasePsychiatry and Mental healthmedicine.anatomical_structureSchizophreniaFemaleSchizophrenic PsychologyNerve NetPsychologyNeurosciencePsychopathologyVigilance (psychology)European Archives of Psychiatry and Clinical Neuroscience
researchProduct