Search results for "FILTER"
showing 10 items of 1019 documents
Argon laser suture lysis following glaucoma filtering surgery – A short introduction to the procedure
2010
Abstract Background Trabeculectomy is the most commonly performed glaucoma filtering surgery. The success of the outcome of an operation to reduce the intraocular pressure (IOP) is dependent on postoperative wound modulation by antimetabolite therapy and by flow regulation of the filtering bleb, which can be achieved by argon laser suture lysis. Methods and case report Postoperative IOP controls, examination of bleb formation and bleb massage can lead to the decision to perform up to four argon laser suture lyses in order to reduce IOP and enhance aqueous humor flow and bleb formation. The procedure is described here in a case report. Conclusion After glaucoma filtering surgery, argon laser…
Diffuse reflectance and fluorescence multispectral imaging system for assessment of skin
2014
The diffuse reflectance multispectral imaging technique has been used for distant mapping of in vivo skin chromophores (hemoglobin and melanin). The fluorescence multispectral imaging is not so common for skin applications due to complicity of data acquisition and processing, but could provide additional information about skin fluorophores. Both techniques are compatible, and could be combined into a multimodal solution. The multispectral imaging system Nuance based on liquid crystal tunable filters was adapted for diffuse reflectance and fluorescence spectral imaging of in vivo skin. Uniform illumination was achieved by LED ring light. Combination of four LEDs (warm white, 770 nm, 830 nm a…
Advanced technologies for detecting tremor in Parkinson's disease.
2019
Objective Accurate and reliable detection of tremor onset in Parkinson’s disease (PD) is critical to the success of adaptive deep brain stimulation (aDBS) therapy. Here, we investigated the potential use of feature engineering and machine learning methods for more accurate detection of rest tremor in PD. Methods We analyzed the local field potential (LFP) recordings from the subthalamic nucleus region in 12 patients with PD (16 recordings). To explore the optimal biomarkers and the best performing classifier, the performance of state-of-the-art machine learning (ML) algorithms and various features of the subthalamic LFPs were compared. We further used a Kalman filtering technique in feature…
Development of a Protocol for CCD Calibration: Application to a Multispectral Imaging System
2005
In this paper we describe in detail a method for calibrating a CCD-based camera. The calibration aims to remove both temporal and systematic noises introduced by the sensor, electronics, and optics after which we can correct the non-linearity of its response. For the non-linearity correction we use a simple and powerful approach consisting on a complementary approach between a polynomial fitting and an LUT based algorithm. The proposed methodology is accurate in the sense that it takes into account individual characteristics of each pixel. In each pixel, systematic noises are measured through acquiring offset images, thermal images, and FlatField images. A rigorous protocol for acquiring th…
High Dynamic Range Spectral Imaging Pipeline For Multispectral Filter Array Cameras
2017
Spectral filter arrays imaging exhibits a strong similarity with color filter arrays. This permits us to embed this technology in practical vision systems with little adaptation of the existing solutions. In this communication, we define an imaging pipeline that permits high dynamic range (HDR)-spectral imaging, which is extended from color filter arrays. We propose an implementation of this pipeline on a prototype sensor and evaluate the quality of our implementation results on real data with objective metrics and visual examples. We demonstrate that we reduce noise, and, in particular we solve the problem of noise generated by the lack of energy balance. Data are provided to the community…
Fluorescein for resection of high-grade gliomas: A safety study control in a single center and review of the literature
2017
Background: The importance of a complete resection of high-grade gliomas (HGGs) has been highlighted in scientific literature, in order to limit tumor recurrence and above all to improve disease-free survival rates. Several fluorescent biomarkers have been tested to improve intraoperative identification of residual tumor; 5-aminolevulinic acid (5-ALA) and fluorescein sodium (FS) are now starting to play a central role in glioma surgery. We performed a retrospective analysis on 47 patients operated for HGGs. Here we report our preliminary data. Methods: Data of 47 consecutive patients with HGG have been collected in our study (25 males, 22 females; mean age: 60.3 years, range: 27-86 years). …
Diagnosis and Treatment of Lower Extremity Venous Thromboembolism
2020
Importance: Incidence rates for lower extremity deep vein thrombosis (DVT) range from 88 to 112 per 100 000 person-years and increase with age. Rates of recurrent VTE range from 20% to 36% during the 10 years after an initial event.Observations: PubMed and Cochrane databases were searched for English-language studies published from January 2015 through June 2020 for randomized clinical trials, meta-analyses, systematic reviews, and observational studies. Risk factors for venous thromboembolism (VTE), such as older age, malignancy (cumulative incidence of 7.4% after a median of 19 months), inflammatory disorders (VTE risk is 4.7% in patients with rheumatoid arthritis and 2.5% in those withou…
Clinical experience with retrievable vena cava filters: results of a prospective observational multicenter study
2005
Summary. Background: Retrievable inferior vena cava (IVC) filters offer the attractive possibility to be definitive or to be removed when they become unnecessary. Objective: The purpose of this study was to evaluate the efficacy and the likelihood to remove the retrievable IVC filter ALN. Methods: A total of 30 patients (13 males and 17 females, mean age 57 ± 15 years) underwent placement of ALN filters. Indications for implantation were acute venous thromboembolism (VTE) with a contraindication to anticoagulation in 26 cases (86%), primary prophylaxis after major trauma in two cases (7%) or before surgery in two patients with very high thromboembolic risk (7%). Results: The filter was succ…
Analysis and evaluation of periodic physiological organ motion in radiotherapy treatments.
2003
Background and purpose: A system for the detection, measurement and analysis of the periodic physiological organ motion during radiotherapy treatment is proposed and clinically tested in this paper. Material and methods: The procedure is based on the acquisition of fluoroscopic sequences, followed by an automatic detection of the movement using cross-correlations with matched filters. Results: The system generates a probability density function (PDF) of finding a mobile organ in a position at a certain time. The maximum path of the mobile structures can be determined to define the planning target volume (PTV) without ambiguities. Conclusions: Physiological movements can be accurately includ…
Biofiltration of airborne VOCs with green wall systems : microbial and chemical dynamics
2018
Botanical air filtration is a promising technology for reducing indoor air contaminants, but the underlying mechanisms need better understanding. Here, we made a set of chamber fumigation experiments of up to 16 weeks of duration, to study the filtration efficiencies for seven volatile organic compounds (VOCs; decane, toluene, 2‐ethylhexanol, α‐pinene, octane, benzene, and xylene) and to monitor microbial dynamics in simulated green wall systems. Biofiltration functioned on sub‐ppm VOC levels without concentration‐dependence. Airflow through the growth medium was needed for efficient removal of chemically diverse VOCs, and the use of optimized commercial growth medium further improved the e…