Search results for "FLE"

showing 10 items of 3517 documents

Sun-induced fluorescence - a new probe of photosynthesis: First maps from the imaging spectrometer HyPlant.

2015

Variations in photosynthesis still cause substantial uncertainties in predicting photosynthetic CO2 uptake rates and monitoring plant stress. Changes in actual photosynthesis that are not related to greenness of vegetation are difficult to measure by reflectance based optical remote sensing techniques. Several activities are underway to evaluate the sun-induced fluorescence signal on the ground and on a coarse spatial scale using space-borne imaging spectrometers. Intermediate-scale observations using airborne-based imaging spectroscopy, which are critical to bridge the existing gap between small-scale field studies and global observations, are still insufficient. Here we present the first …

Chlorophyllinduced fluorescencesunImaging spectrometer2306 Global and Planetary ChangeFluorescence2300 General Environmental SciencePhotosynthesiEnvironmental ChemistryAirborne measurement910 Geography & travelSpectral resolutionPhotosynthesisAbsorption (electromagnetic radiation)Spectroscopyairborne measurementsChlorophyll fluorescenceGeneral Environmental ScienceRemote sensingGlobal and Planetary ChangeSpectrometerEcology2300Remote sensingImaging spectroscopyVegetation monitoringFLEXImaging spectroscopy10122 Institute of GeographyGEO/10 - GEOFISICA DELLA TERRA SOLIDASpectrometry FluorescenceSun-induced fluorescence2304 Environmental ChemistryHyPlantRemote Sensing TechnologySunlightEnvironmental scienceSpatial variabilityChlorophyll fluorescence2303 EcologyGlobal change biology
researchProduct

Partial least squares attenuated total reflectance IR spectroscopy versus chromatography: the greener method

2012

Method election is a complex task that must be done carefully in order to ensure the capability of analytical methodologies to provide appropriate data for problem solving. This is a real challenge in all fields, but especially with bioanalysis, which in many cases involves the need to do a large number of determinations in complex

ChromatographyBioanalysisChromatographyChemistryClinical BiochemistryInfrared spectroscopyGreen Chemistry TechnologyGeneral MedicineAnalytical ChemistryMedical Laboratory TechnologyAttenuated total reflectionSpectroscopy Fourier Transform InfraredPartial least squares regressionLeast-Squares AnalysisGeneral Pharmacology Toxicology and PharmaceuticsBioanalysis
researchProduct

Fast authentication of tea tree oil through spectroscopy

2018

Two new procedures, based on infrared spectroscopy in the near infrared (NIR) and mid infrared (MIR), have been developed for the authentication of tea tree oil (TTO) commercial samples. Infrared measurements were made on untreated samples by transmission NIR and attenuated total reflectance (ATR) followed by partial least square discriminant analysis (PLS-DA). These methods offer a fast and low cost alternative to enantiomeric two-dimensional gas chromatography coupled to mass detection usually employed to discriminate between authentic and non-authentic samples. In these studies, a set of 267 samples, including authentic and non-authentic labelled tea tree oil samples, were used to build …

ChromatographyChemistryInfrared010401 analytical chemistryNear-infrared spectroscopyTea tree oilInfrared spectroscopy02 engineering and technology021001 nanoscience & nanotechnologyLinear discriminant analysis01 natural sciences0104 chemical sciencesAnalytical ChemistryAttenuated total reflectionmedicineGas chromatography0210 nano-technologySpectroscopymedicine.drugTalanta
researchProduct

Comparison of two vibrational procedures for the direct determination of mancozeb in agrochemicals.

2007

The direct determination of mancozeb in agrochemicals has been made by diamond attenuated total reflectance (ATR) Fourier transform infrared spectroscopy in the middle range (DATR-MIR) and diffuse reflectance infrared Fourier transform spectroscopy in the near range (DR-NIR) methods using in both cases a previous identification of the samples using a dendrographic classification and an appropriate partial least squares (PLS) calibration established from a set of nine external standards and optimized for each type of sample. It was analyzed a heterogeneous population of 11 samples obtained from the Spanish market, containing different co-formulated products, such as fosetyl-Al, copper oxychl…

ChromatographyDiffuse reflectance infrared fourier transformChemistryAttenuated total reflectionDirect methodPartial least squares regressionCalibrationAnalytical chemistryInfrared spectroscopyFourier transform infrared spectroscopyFourier transform spectroscopyAnalytical ChemistryTalanta
researchProduct

Essential oil counterfeit identification through middle infrared spectroscopy

2018

Abstract Infrared spectroscopy (FTIR) has been employed for a fast quality control of commercial essential oils from different plant species. 47 samples were obtained from Algerian and Spanish market and directly measured, without any previous treatment, by attenuated total reflectance Fourier transform Infrared spectroscopy (ATR-FTIR), in the wavenumber region between 4000 and 550 cm−1. Pure essential oils were obtained by hydro- and steam-distillation extraction methods and their ATR spectra obtained. Results found evidenced the presence of solvents in some commercial formulations and permitted a rapid authentication of pure essential oils correctly extracted from those diluted. The propo…

ChromatographyMaterials science010405 organic chemistry010401 analytical chemistryInfrared spectroscopy01 natural sciencesEnvironmentally friendly0104 chemical sciencesAnalytical Chemistrylaw.inventionlawAttenuated total reflectionMiddle infraredPlant speciesFourier transform infrared spectroscopySpectroscopySpectroscopyEssential oilMicrochemical Journal
researchProduct

Origin based classification of crude oils by infrared spectrometry and chemometrics

2019

Abstract Crude oil samples from different Iranian petrol resources in both, raw and mixture forms have been characterized by attenuated total reflectance mid infrared spectroscopy. Obtained spectra were classified by chemometric techniques to propose a method for geological based classification of crude oil samples. Totally 251 samples from 7 petrol fields and 3 mixtures were analyzed. Mean centering and principal component analysis (PCA) supported – leverage value based outlier detection were used as preprocessing approaches. PCA, cluster analysis and soft independent modeling of class analogy (SIMCA) were utilized to classify the spectra. Obtained results confirmed that SIMCA is a robust …

ChromatographyMean squared error020209 energyGeneral Chemical EngineeringOrganic ChemistryEnergy Engineering and Power TechnologyInfrared spectroscopy02 engineering and technologyChemometricsFuel TechnologyMean centering020401 chemical engineeringAttenuated total reflectionPrincipal component analysisLinear regression0202 electrical engineering electronic engineering information engineeringLeverage (statistics)0204 chemical engineeringMathematicsFuel
researchProduct

Cr(VI)/Cr(III) and As(V)/As(III) Ratio Assessments in Jordanian Spent Oil Shale Produced by Aerobic Combustion and Anaerobic Pyrolysis

2011

With the increase in the awareness of the public in the environmental impact of oil shale utilization, it is of interest to reveal the mobility of potentially toxic trace elements in spent oil shale. Therefore, the Cr and As oxidation state in a representative Jordanian oil shale sample from the El-Lajjoun area were investigated upon different lab-scale furnace treatments. The anaerobic pyrolysis was performed in a retort flushed by nitrogen gas at temperatures in between 600 and 800 °C (pyrolytic oil shale, POS). The aerobic combustion was simply performed in porcelain cups heated in a muffle furnace for 4 h at temperatures in between 700 and 1000 °C (burned oil shale, BOS). The high loss-…

ChromiumHot TemperatureJordanChemistryMetallurgychemistry.chemical_elementGeneral ChemistryRetortCombustionArseniclaw.inventionChromiumchemistry.chemical_compoundPetroleumCalcium carbonatelawEnvironmental chemistryEnvironmental ChemistryMuffle furnaceOxidation-ReductionPyrolysisOil shaleArsenicEnvironmental Science & Technology
researchProduct

Vascular resistance arm of the baroreflex: methodology and comparison with the cardiac chronotropic arm.

2020

Baroreflex response consists of cardiac chronotropic (effect on heart rate), cardiac inotropic (on contractility), venous (on venous return) and vascular (on vascular resistance) arms. Because of its measurement simplicity, cardiac chronotropic arm is most often analysed. The aim was to introduce a method to assess vascular baroreflex arm, and to characterize its changes during stress. We evaluated the effect of orthostasis and mental arithmetics (MA) in 39 (22 female, median age: 18.7 yrs.) and 36 (21 female, 19.2 yrs.) healthy volunteers, respectively. We recorded systolic and mean blood pressure (SBP and MBP) by volume-clamp method and R-R interval (RR) by ECG. Cardiac output (CO) was re…

ChronotropicMalemedicine.medical_specialtyAdolescentPhysiologyBlood Pressure030204 cardiovascular system & hematologyBaroreflex03 medical and health sciences0302 clinical medicineHeart RatePhysiology (medical)Internal medicinemedicineHumansimpedance cardiographyCardiac OutputArterial baroreflexHeart rate responsemedicine.diagnostic_testbusiness.industrymusculoskeletal neural and ocular physiologyArterial baroreflexBaroreflexspectral couplingImpedance cardiographymedicine.anatomical_structureBlood pressureSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaVascular resistanceCardiologyFemaleVascular Resistancebusiness030217 neurology & neurosurgeryJournal of applied physiology (Bethesda, Md. : 1985)
researchProduct

Selection of blood pressure signal for baroreflex analysis

2020

This study aims to evaluate the strength of the causal coupling among systolic, mean and diastolic blood pressure (SBP, MBP and DBP) with heart period (RR interval) (evaluating cardiac chronotropic baroreflex arm) and peripheral vascular resistance (PVR) (evaluating vascular resistance baroreflex arm) in frequency domain using partial spectral decomposition method. We recorded beat-to-beat RR, SBP, MBP and DBP and PVR values in 39 volunteers during supine rest and head-up tilt. Our results showed that during supine rest the most dominant causal coupling was from DBP to RR in both low and high frequency bands and significantly decreased during orthostasis. The strength of spectral couplings …

Chronotropicmedicine.medical_specialtySupine positionbusiness.industryRR intervalLow frequency bandBaroreflexBlood pressuremedicine.anatomical_structureInternal medicineSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaCardiologyVascular resistanceBlood pressureMedicinecardiovascular diseasesbusinesscirculatory and respiratory physiology
researchProduct

El Mediterráneo: modernidad plural

2000

Es la versión española del texto en francés "La Méditerranée : modernité pluriellel. Introduction". [En: Vidal-Beneyto, José&de Puymège, Gérard (Ed.&Coord.) (2000). La Méditerranée: modernité plurielle. Éditions UNESCO - Publisud].Hay, además, una versión española más larga de este texto en: Blanc Altemir, Antonio (Ed.) (1999). El Mediterráneo : un espacio común para la cooperación, el desarrollo y el diálogo intercultural. Madrid: Foca.

CienciaCulturaCooperaciónVidal-Beneyto JoséGlocalidadAproximación teóricaPrácticas geopolíticasTecnologíaPrograma MediterráneoReflexiónMEDITERRÁNEOConsejo de EuropaEco-culturalVida cotidianaUNESCOAcción mediterráneaLocalPublicaciones: Obra académico-científica: Artículos en revistas científicasInvestigaciónRedes mediterráneasPaíses mediterráneosMundialInterdependencia
researchProduct