Search results for "Failure Analysis"
showing 10 items of 132 documents
Multi-objective optimization of nitinol stent design.
2017
Nitinol stents continuously experience loadings due to pulsatile pressure, thus a given stent design should possess an adequate fatigue strength and, at the same time, it should guarantee a sufficient vessel scaffolding. The present study proposes an optimization framework aiming at increasing the fatigue life reducing the maximum strut strain along the structure through a local modification of the strut profile.The adopted computational framework relies on nonlinear structural finite element analysis combined with a Multi Objective Genetic Algorithm, based on Kriging response surfaces. In particular, such an approach is used to investigate the design optimization of planar stent cell.The r…
A microcontroller-based portable electrocardiograph recorder.
2004
We describe a low cost portable Holler design that can be implemented with off-the-shelf components. The recorder is battery powered and includes a graphical display and keyboard. The recorder is capable of acquiring up to 48 hours of continuous electrocardiogram data at a sample rate of up to 250 Hz.
Rotor-bar breakage mechanism and prognosis in an induction motor
2015
© 1982-2012 IEEE. This paper proposes a condition-based maintenance and prognostics and health management (CBM/PHM) procedure for a rotor bar in an induction motor. The methodology is based on the results of a fatigue test intended to reproduce in the most natural way a bar breakage in order to carry out a comparison between transient and stationary diagnosis methods for incipient fault detection. Newly developed techniques in stator-current transient analysis have allowed tracking the developing fault during the last part of the test, identifying the failure mechanism, and establishing a physical model of the process. This nonlinear failure model is integrated in a particle filtering algor…
Instrumentation, control, and automation for submerged anaerobic membrane bioreactors
2015
A submerged anaerobic membrane bioreactor (AnMBR) demonstration plant with two commercial hollow-fibre ultrafiltration systems (PURON® , Koch Membrane Systems, PUR-PSH31) was designed and operated for urban wastewater treatment. An instrumentation, control, and automation (ICA) system was designed and implemented for proper process performance. Several single-input-single-output (SISO) feedback control loops based on conventional on off and PID algorithms were implemented to control the following operating variables: flow-rates (influent, permeate, sludge recycling and wasting, and recycled biogas through both reactor and membrane tanks), sludge wasting volume, temperature, transmembrane pr…
The Use of Accelerometers and Gyroscopes to Estimate Hip and Knee Angles on Gait Analysis
2014
In this paper the performance of a sensor system, which has been developed to estimate hip and knee angles and the beginning of the gait phase, have been investigated. The sensor system consists of accelerometers and gyroscopes. A new algorithm was developed in order to avoid the error accumulation due to the gyroscopes drift and vibrations due to the ground contact at the beginning of the stance phase. The proposed algorithm have been tested and compared to some existing algorithms on over-ground walking trials with a commercial device for assisted gait. The results have shown the good accuracy of the angles estimation, also in high angle rate movement.
New statistical post processing approach for precise fault and defect localization in TRI database acquired on complex VLSI
2013
International audience; Timing issue, missing or extra state transitions or unusual consumption can be detected and localized by Time Resolved Imaging (TRI) database analysis. Although, long test pattern can challenge this process. The number of photons to process rapidly increases and the acquisition time to have a good signal over noise ratio (SNR) can be prohibitive. As a result, the tracking of the defect emission signature inside a huge database can be quite complicated. In this paper, a method based on data mining techniques is suggested to help the TRI end user to have a good idea about where to start a deeper analysis of the integrated circuit, even with such complex databases.
Struvite formation from the supernatants of an anaerobic digestion pilot plant
2009
This work studied the influence of the characteristics of the supernatants on the struvite precipitation process. Eighteen experiments with the supernatants generated in an anaerobic digestion pilot plant were performed in a stirred reactor. In order to obtain the pH control during the crystallization process, a Fuzzy Logic based controller was used. High phosphorus precipitation and recovery efficiencies were obtained. The composition of the supernatants was analyzed in order to study its influence on the solids formed from those solutions. The presence of calcium reduced the percentage of phosphorus precipitated as struvite leading to the formation of amorphous calcium phosphate (ACP), wh…
Taking Advantage of Selective Change Driven Processing for 3D Scanning
2013
This article deals with the application of the principles of SCD (Selective Change Driven) vision to 3D laser scanning. Two experimental sets have been implemented: one with a classical CMOS (Complementary Metal-Oxide Semiconductor) sensor, and the other one with a recently developed CMOS SCD sensor for comparative purposes, both using the technique known as Active Triangulation. An SCD sensor only delivers the pixels that have changed most, ordered by the magnitude of their change since their last readout. The 3D scanning method is based on the systematic search through the entire image to detect pixels that exceed a certain threshold, showing the SCD approach to be ideal for this applicat…
Label swapper device for spectral amplitude coded optical packet networks monolithically integrated on InP
2011
In this paper the design, fabrication and experimental characterization of an spectral amplitude coded (SAC) optical label swapper monolithically integrated on Indium Phosphide (InP) is presented. The device has a footprint of 4.8x1.5 mm 2 and is able to perform label swapping operations required in SAC at a speed of 155 Mbps. The device was manufactured in InP using a multiple purpose generic integration scheme. Compared to previous SAC label swapper demonstrations, using discrete component assembly, this label swapper chip operates two order of magnitudes faster. © 2011 Optical Society of America.
Automatable sample fabrication process for pump-probe X-ray holographic imaging
2014
Soft X-ray holography is a recently developed imaging technique with sub-50 nm spatial resolution. Key advantages of this technique are magnetic and elemental sensitivity, compatibility with imaging at free electron laser facilities, and immunity to in-situ sample excitations and sample drift, which enables the reliable detection of relative changes between two images with a precision of a few nanometers. In X-ray holography, the main part of the experimental setup is integrated in the sample, which consequently requires a large number of fabrication steps. Here we present a generic design and an automatable fabrication process for samples suitable, and optimized for, efficient high resolut…