Search results for "Failure analysis"
showing 10 items of 132 documents
Through-focus response of multifocal intraocular lenses evaluated with a spatial light modulator
2012
A new testing technique based on the use of a liquid crystal spatial light modulator (SLM) is proposed to analyze the optical quality of multifocal intraocular lenses (MIOLs). Different vergences and decentrations of the incident beam can be programmed onto the SLM in order to record the point spread function (PSF) for different object positions. From these axial PSFs, the through-focus modulation transfer function is computed. Because there are no moving parts in the experimental setup, this method is fast and versatile to assess MIOLs. Experimental results confirm the potential of the proposed method.
Low-energy epicardial pacing in children: the benefit of autocapture.
1999
Abstract Background . Permanent cardiac pacing in children results commonly in augmented energy consumption because of the high pacing rates and the ample stimulation safety margin applied in children. Cardiovascular anatomy and limited venous access sometimes preclude the otherwise preferred endocardial approach. In this multicenter patient series, we studied the feasibility, safety, and energy saving obtained by a combination of steroid-eluting epicardial leads with autocapture devices capable of ongoing adjustment of the stimulation output to the prevailing threshold. Methods . Autocapture devices (Pacesetter Microny SR+ and Regency SR+; Pacesetter, Solna, Sweden) and steroid-eluting epi…
Ventilator Settings to Avoid Nuisance Alarms During Mouthpiece Ventilation
2016
BACKGROUND: A recent study found that activation of disconnection and low-pressure alarms is common during mouthpiece ventilation and may represent a major limitation to its use. The aim of this bench study was: (1) to investigate the technical aspects that can influence the setting of the ventilator during mouthpiece ventilation and (2) to provide a practical setting strategy to avoid the alarm activation. METHODS: Eight life-support ventilators able to deliver volume controlled ventilation were tested in a bench study using a single-limb non-vented circuit configuration connected to a standard mouthpiece. Disconnection and apnea alarm were turned off or set at the least sensitive setting.…
Optimization of fluorescence enhancement for silicon-based microarrays
2008
An optical technique for the enhancement of fluorescence detection sensitivity on planar samples is presented. Such a technique is based on the simultaneous optimization of excitation and light collection by properly combining interference and reflectance from the sample holder. Comparative tests have been performed in microarray applications, by evaluating the proposed solution against commercial glass-based devices, using popular labeling dyes, such as Cy3 and Cy5. The proposed technique is implemented on a substrate built with standard silicon technology and is therefore well suited for integrated micro total analysis systems (microTAS) applications.
Generation of narrowband antisymmetric lamb waves using a formed laser source in the ablative regime
2007
A formed laser source, using a four-element lenticular array, is used in the ablative regime to generate select, narrowband, acoustic plate waves. The arrangement of the array produces acoustical signals that have frequencies compatible with the response of the broadband capacitive air-coupled transducer used in this study. A simplified concept is presented to explain the effect of a line array source on the frequency content of acoustic waves. The analytical model for a point pulse surface displacement is derived from the point load solution to Lamb's problem. The point pulse displacement elements of a line array source are summed mathematically, taking into account all applicable propagat…
Numerical expressions for the computation of coincidence-summing correction factors in γ-ray spectrometry with HPGe detectors
2009
Numerical expressions to compute gamma-gamma and gamma-X(K) coincidence summing corrections were deduced by using a suitable computer program and a matrix representation of a decay scheme. For point sources only full-energy peak and total efficiencies are needed. Alternatively, values of peak-to-total ratio can be introduced. For extended sources, the same expressions can be considered with the introduction of "effective efficiencies". Examples of the use of the expressions for point sources and a particulate filter sample measured with a 60% relative efficiency HPGe detector are reported.
Optical rogue-wave-like extreme value fluctuations in fiber Raman amplifiers
2008
International audience; We report experimental observation and characterization of rogue wave-like extreme value statistics arising from pump-signal noise transfer in a fiber Raman amplifier. Specifically, by exploiting Raman amplification with an incoherent pump, the amplified signal is shown to develop a series of temporal intensity spikes whose peak power follows a power-law probability distribution. The results are interpreted using a numerical model of the Raman gain process using coupled nonlinear Schrödinger equations, and the numerical model predicts results in good agreement with experiment.
Risk analysis using fuzzy set theory of accidental exposure of medical staff during brachytherapy procedures
2010
Using fuzzy set theory, this paper presents results from risk analyses that explore potential exposure of medical operators working in a high dose rate brachytherapy irradiation plant. In these analyses, the HEART methodology, a first generation method for human reliability analysis, has been employed to evaluate the probability of human error. This technique has been modified on the basis of fuzzy set concepts to take into account, more directly, the uncertainties of the so-called error-promoting factors on which the method is based. Moreover, with regard to some identified accident scenarios, fuzzy potential dose was also evaluated to estimate the relevant risk. The results also provide s…
The pre-vascularisation of a collagen-chondroitin sulphate scaffold using human amniotic fluid-derived stem cells to enhance and stabilise endothelia…
2015
Abstract A major problem in tissue engineering (TE) is graft failure in vivo due to core degradation in in vitro engineered constructs designed to regenerate thick tissues such as bone. The integration of constructs post-implantation relies on the rapid formation of functional vasculature. A recent approach to overcome core degradation focuses on the creation of cell-based, pre-engineered vasculature formed within the TE construct in vitro , prior to implantation in vivo . The primary objective of this study was to investigate whether an amniotic fluid-derived stem cell (AFSC)–human umbilical vein endothelial cell (HUVEC) co-culture could be used to engineer in vitro vasculature in a collag…
Photonic fractional Fourier transformer with a single dispersive device
2013
In this work we used the temporal analog of spatial Fresnel diffraction to design a temporal fractional Fourier transformer with a single dispersive device, in this way avoiding the use of quadratic phase modulators. We demonstrate that a single dispersive passive device inherently provides the fractional Fourier transform of an incident optical pulse. The relationships linking the fractional Fourier transform order and scaling factor with the dispersion parameters are derived. We first provide some numerical results in order to prove the validity of our proposal, using a fiber Bragg grating as the dispersive device. Next, we experimentally demonstrate the feasibility of this proposal by us…