Search results for "Fault"
showing 10 items of 610 documents
Latent Nestling Method: A new fault diagnosis methodology for complex systems
2008
This paper presents a new methodology for permanent and intermittent fault diagnosis, named faults latent nestling method (FLNM), using coloured Petri nets (CPNs). CPNs and FLNM method allow for an enhanced capability for synthesis and modelling of complex systems in contrast to the classical phenomena of combinational state explosion when using finite state machine based methods.
Fault diagnosis with Coloured Petri Nets using Latent Nestling Method
2008
This paper presents a new methodology for permanent and intermittent fault diagnosis, named Faults Latent Nestling Method (FLNM), using Coloured Petri Nets (CPNs). CPNs and FLNM method allow for an enhanced capability for synthesis and modelling in contrast to the classical phenomena of combinational state explosion when using Finite State Machine based methods.
Vibration signature analysis for monitoring rotor broken bar in double squirrel cage induction motors based on wavelet analysis
2014
Purpose – The purpose of this paper is to present a diagnosis technique, for rotor broken bar in double cage induction motor, based on advanced use of wavelet transform analysis. The proposed technique is experimentally validated. Design/methodology/approach – The proposed approach is based on a combined use of frequency sliding and wavelet transform analysis, to isolate the contribution of the rotor fault components issued from vibration signals in a single frequency band. Findings – The proposed technique is reliable for tracking the rotor fault components over time-frequency domain. The quantitative analysis results based on this technique are the proof of its robustness. Research limit…
An imprecise Fault Tree Analysis for the estimation of the Rate of OCcurrence Of Failure (ROCOF)
2013
Abstract The paper proposes an imprecise Fault Tree Analysis in order to characterize systems affected by the lack of reliability data. Differently from other research works, the paper introduces a classification of basic events into two categories, namely Initiators and Enablers . Actually, in real industrial systems some events refer to component failures or process parameter deviations from normal operating conditions ( Initiators ), whereas others refer to the functioning of safety barriers to be activated on demand ( Enablers ). As a consequence, the output parameter of interest is not the classical probability of occurrence of the top event, but its Rate of OCcurrence (ROCOF) over a s…
A new methodology for distribution systems faults identification, location and characterization
2005
PurposeIdentify a new methodology for fault characterization, identification and location in electrical distribution systems, based on the use of matrix algebra.Design/methodology/approachThe developed diagnostic methodology is based on a high precision analytical model of the network using a distributed parameters representation.FindingsTest results have proved the approach to be efficient and precise, while providing a generalized quadripolar model of a line affected by the most common kinds of fault.Research limitations/implicationsGeneralization to a greater number of fault cases, experimental tests.Practical implicationsUtilities are quite interested in such items, since the new requir…
A Simple Method for Evaluating Ground-Fault Current Transfer at the Transition Station of a Combined Overhead-Cable Line
2008
When a substation is fed by a combined overhead-cable transmission line, a significant part of the ground fault current flows through cable sheaths and is discharged into the soil at the transition station where cables are connected to the overhead line. Such a phenomenon, known as ldquofault application transfer,rdquo may result in high ground potentials at the transition station which may cause shocks and equipment damage. The scope of this paper is to present new analytic formulas which can be used for the direct calculation of the fault current transferred at the transition station and its ground potential rise as well as the substation earth current. The proposed formulas allow evaluat…
A Method to Evaluate Voltages to Earth During an Earth Fault in an HV Network in a System of Interconnected Earth Electrodes of MV/LV Substations
2008
An easy and swift method to evaluate, in a system of interconnected earth electrodes, earth potentials on earthing systems of medium-voltage/low-voltage (MV/LV) substations, in an event of single-line-to-earth fault inside a high-voltage/medium- voltage (HV/MV) station, is presented. The advantage of the method is the simplicity of the mathematical model for solving complex systems of any size with a sufficient accuracy for practical purposes. This paper shows the results of simulations, performed on networks with different extensions and characteristics, organized in easy-to-read graphs and tables. A comparison of these results with the values obtained according to the procedure explained …
DOUBLE EARTH FAULT EFFECTS IN PRESENCE OF INTERCONNECTED EARTH ELECTRODES
2009
The paper presents a study on the effects of double earth faults in Medium Voltage (MV) networks, in presence of electrical interconnection of the earthing systems of the secondary substations. In urban areas, indeed, the earth electrodes of the secondary substations are interconnected and, in many cases, they are also connected to the earth electrodes of the primary stations, in order to realize quasi-equipotential surfaces, intrinsically safe against electric shocks, named Global Earthing Systems (GES). The concept of GES has been introduced in the technical literature ten years ago in the Document HD 637 S1 by CENELEC, with the aim of providing a solution to the problems of designing and…
The Quest for Global Safety
2007
The authors present a systematic study on the factors that have influence on the establishment of the safety conditions ensuring the rise of Global Earthing Systems. Starting from the definition of Global Earthing System given by CENELEC Document HD 637 SI and from the results of the studies done on the last years on the interconnected earthing systems inside MV networks, the paper proposes some directions of deepening on the topic of Global Safety. Some of the themes whom the paper deals with are: the correct definition of proximity, interconnection and quasi-equipotentiality of the earth electrodes belonging to a Global Earthing System; the influence of the presence of HV/MV stations on h…
On the effects of HV/MV stations on global grounding systems
2016
The METERGLOB project has faced the issue of the identification of Global Grounding Systems. One of the main point of the problem is to define if an interconnection of single grounding systems gives place to a Global Grounding System in any condition and for every kind of ground fault. This paper focuses the attention on what happens in the case of single line to ground fault inside a HV/MV station whose ground electrode is connected to the cable' shields of the MV lines outgoing the station and supplying the secondary substations of a given area.