Search results for "Fibril"
showing 10 items of 836 documents
Impact of insulin resistance on cardiac and vascular function.
2016
Background Insulin resistance (IR), constitutes an important cardiovascular risk factor and can cause ischemic heart disease. It can lead to left ventricular dysfunction with a mechanism independent of ischemic heart disease and it is closely associated with impaired vascular function. The aim of our study was to explore the impact of IR on cardiac and vascular function, in patients with cardiovascular risk factors but angiographically undamaged coronary arteries. Methods We studied 32 patients (62.06 ± 11.19 years) with cardiovascular risk factors. All patients underwent coronary angiography, echocardiography, Doppler ultrasound of carotid arteries and laboratory tests. Exclusion criteria …
Prevalence of atrial fibrillation in intracerebral hemorrhage
2013
Background and purpose Oral anticoagulation (OAC) is an effective preventive therapy for ischemic stroke in atrial fibrillation (AF). The management of anticoagulation in AF patients with previous intracerebral hemorrhage (ICH) is challenging. The aim of this study was to determine the prevalence of AF after acute ICH in a consecutive monocenter cohort, and to document the subsequent management with respect to OAC. Methods Consecutive patients with spontaneous ICH were prospectively included within 19 months. Diagnosis of AF was based on medical history, 12-lead electrocardiogram (ECG), 24-h and continuous ECG monitoring. CHADS2 scores and patient medication were recorded at admission and a…
Clinical predictors to identify paroxysmal atrial fibrillation after ischaemic stroke.
2013
Background and purpose Detection of paroxysmal atrial fibrillation (pAF) after an ischaemic cerebrovascular event is of imminent interest, because oral anticoagulation as a highly effective secondary preventive treatment is available. Whereas permanent atrial fibrillation (AF) can be detected during routine electrocardiogram (ECG), longer detection duration will detect more pAF but might be resource consuming. The current study tried to identify clinical predictors for pAF detected during long-term Holter ECG and clinical follow-up. Methods Patients with acute ischaemic stroke were prospectively investigated with an intensified algorithm to detect pAF (7-day Holter ECG, follow-up investigat…
Natural history of the Sprint Fidelis lead: survival analysis from a large single-center study.
2012
The purposes of our study were to: (1) determine lead failure rate in a large single-center cohort of Sprint Fidelis 6949 (Fidelis) leads, (2) define the risk of lead failure over time, (3) assess the impact of the Lead Integrity Alert (LIA) on lead failure presentation, and (4) identify independent predictors of Fidelis lead failure. All patients who underwent implantation of a Fidelis lead between September 2004 and July 2007 were included. Demographic, clinical, and device characteristics at the time of implant and prior to failure were collected and analyzed. A total of 971 Fidelis leads (706 men, 265 women, mean age 68.4 ± 12.8 years) were implanted. Over a mean follow-up of 46.3 month…
Prognosis of silent atrial fibrillation after acute myocardial infarction at 1-year follow-up
2014
Silent atrial fibrillation (AF), assessed by continuous ECG monitoring (CEM), has recently been shown to be common in acute myocardial infarction (AMI), and associated with higher hospital mortality. However, the long-term prognosis is still unknown. We aimed to assess 1-year prognosis in patients experiencing silent AF in AMI.All consecutive patients with AMI who were prospectively analysed by CEM during the first 48 h after admission and who survived at hospital discharge were included. Silent AF was defined as asymptomatic episodes lasting at least 30 s. Patients were followed up at 1 year for cardiovascular (CV) outcomes.Among the 737 patients analysed, 106 (14%) developed silent AF and…
The disruption of myofibre structures in rat skeletal muscle after forced lengthening contractions.
1998
Specific antibodies against structural proteins (actin, desmin, dystrophin, fibronectin) of muscle fibres were used to study the effect of forced lengthening contractions on muscle microarchitecture. Tibialis anterior (TA) muscle of male Wistar rats were subjected to 240 forced lengthening contractions. At consecutive time points (0, and 6 h, 2, 4, and 7 days) after stimulation, the TA muscle was excised for biochemical and histological assays. Beta-Glucuronidase activity, a quantitative indicator of muscle damage, showed increased values 2-7 days after the lengthening, peaking on day 4 (11.7-fold increase). A typical course of histopathological changes (myofibre swelling, necrosis and rege…
Permanent Pacemaker Lead Insertion Connected to an External Pacemaker Generator for Temporary Pacing After Transcatheter Aortic Valve Implantation.
2019
Abstract Background Outcomes after transcatheter aortic valve implantation (TAVI) have been demonstrated to be at least equivalent in the short term compared to surgical valve implantation (SAVI). However, Conduction abnormalities are more common after TAVI than SAVI and the need for permanent pacemaker implantation is more common after TAVI with the currently commercially available self-expanding valves than after SAVI. Temporary pacemaker implantation may be associated with inability to ambulate, lead migration or perforation and infection. Depending on the monitoring system, some arrhythmias may not be detected. We examined the feasibility and safety of permanent pacemaker lead implantat…
Paroxysmal atrial fibrillation and high degree AV block: use of single-lead VDDR pacing with mode switching.
1998
Dual chamber rate responsive pacing incorporating a mode switching option is increasingly used in patients with chronic paroxysmal atrial fibrillation and high degree AV block. Single-lead VDDR pacemakers have rarely used for this indication. The purpose of this study was to determine their reliability of atrial sensing during atrial fibrillation, the percentage of atrial synchronous ventricular pacing, and the behavior of the sinus rate outside the phases of atrial fibrillation. We studied ten patients with a single-lead VDDR pacemaker implanted for this indication. Follow-up visits were performed at predischarge and after 1, 3, 6, 12, 18, and 24 months. During the mean follow-up period of…
Automatic detection of paroxysmal atrial fibrillation in patients with ischaemic stroke: better than routine diagnostic workup?
2016
Background and purpose Prolonged electrocardiogram (ECG) monitoring after ischaemic stroke increases the diagnostic yield of paroxysmal atrial fibrillation (pAF). In order to facilitate the additional workload involved in ECG analysis due to prolonged monitoring times, we investigated the effectiveness of pAF detection with an automated software algorithm (SA) in comparison to the routine staff-based analysis (RA) during standard stroke-unit care. Therefore, patients with acute ischaemic stroke or transitory ischaemic attack presenting with sinus rhythmus on the admission ECG and no history of atrial fibrillation were prospectively included. Methods A 24-h Holter ECG assessment was performe…
Cognitive, biochemical, and imaging profile of patients suffering from idiopathic normal pressure hydrocephalus
2011
Abstract Introduction It has still not been clearly established whether the cognitive deficits of idiopathic normal pressure hydrocephalus (iNPH) are caused by a disturbance in cerebrospinal fluid (CSF) dynamics or an underlying metabolic disturbance. Objective To identify the possible associations between biochemical markers, the neuroimaging characteristics, and cognitive deficits of patients undergoing investigations for possible iNPH. Methods A CSF sample obtained during a lumbar puncture from 10 patients with iNPH was analyzed for several biochemical markers (lactate, 8-isoprostane, vascular endothelial growth factor [VEGF], neurofilament heavy protein, glial fibrillary acidic protein,…