Search results for "Fluorescence spectrometry"

showing 10 items of 99 documents

Determination of total arsenic in soft drinks by hydride generation atomic fluorescence spectrometry

2007

Abstract A highly sensitive and simple method has been developed for the determination of total arsenic, by continuous hydride generation and atomic fluorescence spectrometry (HGAFS), in refreshing drink samples as colas, teas and fruit juices. Samples were mixed with concentrated HCl and KI to obtain final concentrations of 2 mol l−1 and 1%, respectively. These solutions were aspirated and merged with a reducing NaBH4 3% (m/v) solution, with sample and NaBH4 flow rates of 12.5 and 1.5 ml min−1, respectively. The hydride generated in a 170 cm reaction coil was transported to the detector with an Ar flow of 400 ml min−1. The recovery values of added concentrations, from 0.1 to 0.9 ng ml−1, o…

Detection limitChromatographyChemistryHydrideFluorescence spectrometryAnalytical chemistrychemistry.chemical_elementGeneral MedicineAtomic fluorescence spectrometryAnalytical ChemistryHighly sensitiveVolumetric flow rateAshingArsenicFood ScienceFood Chemistry
researchProduct

Non-chromatographic speciation of toxic arsenic in vegetables by hydride generation-atomic fluorescence spectrometry after ultrasound-assisted extrac…

2007

A non-chromatographic, sensitive and simple analytical method has been developed for the determination of toxic arsenic species in vegetable samples by hydride generation-atomic fluorescence spectrometry (HG-AFS). As(III), As(V), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) were determined by hydride generation-atomic fluorescence spectrometry using a series of proportional equations. The method is based on a single extraction of the arsenic species considered from vegetables through sonication at room temperature with H(3)PO(4) 1 mol L(-1) in the presence of 0.1% (w/v) Triton XT-114 and washing of the solid phase with 0.1% (w/v) EDTA, followed by direct measurement of the co…

Detection limitChromatographyChromatographyChemistryHydridemedia_common.quotation_subjectSonicationSpectrophotometry AtomicExtraction (chemistry)Fluorescence spectrometrychemistry.chemical_elementArsenicalsAnalytical ChemistryArsenicSpeciationSpectrometry FluorescenceVegetablesCacodylic AcidSample preparationPhosphoric AcidsUltrasonicsArsenicmedia_commonHydrogenTalanta
researchProduct

Determination of arsenic and antimony in milk by hydride generation atomic fluorescence spectrometry

2002

Abstract A highly sensitive procedure has been developed for total arsenic and antimony determination in milk samples by hydride generation atomic fluorescence spectrometry after microwave-assisted sample digestion. The discrete introduction of 2 ml of digested sample in the automated continuous flow hydride generation system allows us to reduce drastically the sample and HCl consume and to determine several elements from a same sample digestion. The method provides detection limits of 0.006 and 0.003 ng ml−1, a sensitivity of 2390 and 2840 fluorescence units per ng ml−1 for As and Sb respectively, and average relative standard deviation of 2.3% for As and 4.8% for Sb. The analysis of cow m…

Detection limitChromatographyDigestion (alchemy)chemistryAntimonyHydrideFluorescence spectrometryAnalytical chemistrychemistry.chemical_elementQuantitative analysis (chemistry)Inductively coupled plasma mass spectrometryArsenicAnalytical ChemistryTalanta
researchProduct

Application of ACC method to synchronous luminiscence: determination of alpha-tocopherol and alpha-tocopheryl acetate in beverages.

2001

A new method based on the Q parameter, that permits the determination of the C(compound A)/C(compound B) ratio without preparing calibration graphs of the two compounds, is proposed. This method has been applied to signals obtained by synchronous luminiscence. Simultaneous determination of alpha-tocopherol and alpha-tocopheryl acetate in beverages using synchronous fluorescence has been carried out. To isolate the compounds from samples, liquid extraction with n-hexane as the organic phase was employed. The presence of interferences was tested using the apparent content curves (ACC) method and the C(alpha-tocopherol)/C(alpha-tocopheryl acetate) ratio was calculated using the Q parameter. Th…

Detection limitChromatographyExtraction (chemistry)Fluorescence spectrometryAnalytical chemistryReproducibility of ResultsAcetatesBiochemistrySensitivity and SpecificityBeverageschemistry.chemical_compoundSpectrometry FluorescencechemistryModels ChemicalLuminescent MeasurementsSolventsHexanesVitamin ETocopheryl acetateTocopherolalpha-TocopherolQuantitative analysis (chemistry)Vitamin E AcetateFresenius' journal of analytical chemistry
researchProduct

Changes in yield ofin-vivo fluorescence of chlorophyll a as a tool for selective herbicide monitoring

1993

Triazines and derivatives of phenylurea, which are often found in outdoor water samples, induce specific changes in the yield of thein-vivo chlorophyll α-fluorescence of PSII. These changes are correlated quantitatively with the concentration of the herbicides and can therefore be used to set-up a low-price monitor system. In order to detect selectively the herbicide-sensitive part of the fluorescence emission a pulse amplitude modulated fluorimeter was used. The bioassay system was optimised with respect to test organism, growing and measuring conditions. The relationship between fluorescence yield and herbicide concentrations were experimentally determined for the triazines atrazine and s…

Detection limitChromatographyFluorescence spectrometryDCMUSimazinePlant ScienceAquatic Sciencechemistry.chemical_compoundchemistryChlorophyllFluorometerEnvironmental chemistryBioassayAtrazineJournal of Applied Phycology
researchProduct

Enhanced flow-injection–chemiluminometric determination of sulphonamides by on-line photochemical reaction

2003

Abstract The viability of the tandem photochemical reaction-chemiluminescence detection has been studied for an heterogeneous group of sulphonamides (sulphamethoxazole, sulphadiazine, sulphamerazine, sulphamethoxypyridazine, sulphacetamide, sulphadimidine, sulphanilamide, sulphathiazole and sulphaguanidine) using sulphamethoxazole (whose chemiluminescent behaviour has not been previously reported) as a test substance. The ‘on-line’ photochemical-reaction of sulphonamides provides an enhancing influence on the chemiluminometric response of the drugs during their oxidation by potassium permanganate in sulphuric acid medium (sulphamethoxazole, sulphacetamide, sulphadimidine and sulphanilamide …

Detection limitChromatographyFluorescence spectrometryPhotochemistryBiochemistryOrders of magnitude (mass)Analytical Chemistrylaw.inventionStandard curvePotassium permanganatechemistry.chemical_compoundchemistrylawSulphaguanidineEnvironmental ChemistryPhotodegradationSpectroscopyChemiluminescenceAnalytica Chimica Acta
researchProduct

Hydride generation atomic fluorescence spectrometric determination of ultratraces of selenium and tellurium in cow milk

2003

Abstract A sensitive procedure has been developed for selenium and tellurium determination in milk by hydride generation atomic fluorescence spectrometry (HG-AFS) after microwave-assisted sample digestion. The method provides sensitivity values of 1591 and 997 fluorescence units ng−1 ml−1 with detection limits of 0.005 and 0.015 ng ml−1 for Se and Te, respectively. The application of the developed methodology to the analysis of cow milk samples of the Spanish market evidenced the presence of concentration ranges from 11.1 to 26.0 ng ml−1 for Se, and from 1.04 to 9.7 ng ml−1 for Te having found a good comparability with data obtained after dry-ashing of samples.

Detection limitChromatographyHydrideMicrowave ovenchemistry.chemical_elementBiochemistryAtomic fluorescence spectrometryFluorescenceAnalytical ChemistryCow milkchemistryEnvironmental ChemistryTelluriumSpectroscopySeleniumAnalytica Chimica Acta
researchProduct

Multicommutation hydride generation atomic fluorescence determination of inorganic tellurium species in milk

2005

Abstract A multicommutated flow system has been developed for hydride generation, atomic fluorescence (HG-AFS) determination of tellurate (Te VI ) and tellurite (Te IV ) in milk samples. After a batch leaching of Te by sonication at room temperature for 10 min with aqua regia, sample slurries in acidic medium were merged with sodium borohydride and HCl to obtain data on Te IV . Another portion of the acidic slurry was mixed with KBr and passed through a reaction coil introduced inside a microwave oven to reduce quantitatively Te VI to Te IV which was analyzed by HG-AFS. The detection limit was 0.57 ng g −1 in the original samples. The linear range obtained was till 4 ng ml −1 and the averag…

Detection limitHydrideMicrowave ovenFluorescence spectrometryAnalytical chemistrychemistry.chemical_elementGeneral MedicineTellurateAnalytical Chemistrychemistry.chemical_compoundchemistryReagentAqua regiaTelluriumFood ScienceFood Chemistry
researchProduct

Oxidation of adrenaline and noradrenaline by solved molecular oxygen in a FIA assembly.

2002

A simple and effective procedure is proposed for the study and simultaneous determination of adrenaline and noradrenaline. The fluorimetric determination of both substances is performed in a flow injection assembly and by oxidation of both drugs with the solved molecular oxygen. The influence of different parameters is empirically studied and the interpretation of the reaction mechanism is also added. The determination of adrenaline is monitored at 450 nm and the outputs at 520 nm correspond to the adrenaline and noradrenaline global amount; for both lectures lambda(exc) 329 nm. The influence of temperature is relevant and analytical determination occurred at 55 degrees C by immersing the s…

Detection limitReaction mechanismChromatographyEpinephrineChemistryClinical BiochemistryAnalytical chemistryFluorescence spectrometryPharmaceutical ScienceFluorescence spectroscopyAnalytical ChemistryOxygenNorepinephrineLinear rangeDrug DiscoveryFlow Injection AnalysisFluorometryMolecular oxygenQuantitative analysis (chemistry)Oxidation-ReductionSpectroscopyAnalysis methodJournal of pharmaceutical and biomedical analysis
researchProduct

Non-chromatographic speciation of inorganic arsenic in mushrooms by hydride generation atomic fluorescence spectrometry

2009

Abstract A non-chromatographic speciation method has been developed for the determination of inorganic arsenic in cultivated and wild mushroom samples from different origins. The ultrasound-assisted extraction of the toxic arsenic species As (III) and As (V) was performed for 10 min with 1 mol l −1 H 3 PO 4 and 0.1% (m/v) Triton X-100. After phase separation the residue was washed with 0.1% (w/v) EDTA and centrifuged. As (III) and As (V) were determined by hydride generation atomic fluorescence spectrometry. Speciation was made using proportional equations corresponding to two different measurement conditions, (i) directly feeding sample extracts diluted with HCl and (ii) after reduction wi…

Detection limitResidue (complex analysis)ChromatographyHydrideExtraction (chemistry)Fluorescence spectrometrychemistry.chemical_elementGeneral MedicineAscorbic acidMass spectrometryAnalytical ChemistrychemistryArsenicFood ScienceFood Chemistry
researchProduct