Search results for "Fluoroscopy"
showing 10 items of 54 documents
Impact of fluoroscopy on oral double-balloon enteroscopy: results of a randomized trial in 156 patients
2010
Background and study aims The routine utility of fluoroscopy during double-balloon enteroscopy (DBE) via the oral route has been not prospectively evaluated. Up to now, there have been no prospective randomized trials to assess whether fluoroscopy improves outcomes. The aim of this study was to assess the value of fluoroscopy during oral DBE. Patients and methods A total of 156 patients (88 men, 56.4 %) of mean (standard deviation [SD]) age 56 (19) years were randomly assigned to undergo oral DBE either with or without fluoroscopy. The majority of the patients had obscure gastrointestinal bleeding (n = 96, 62 %). The primary target criteria for the study were postpyloric insertion depth and…
Hiatal hernia, gastro-oesophageal reflux and oesophagitis: videofluorographic, endoscopic and histopathological correlation
2004
The aim of the study was to evaluate the correlation between hiatal hernia and gastro-oesophageal reflux and related histological abnormalities in patients without endoscopic oesophagitis. A consecutive series of 78 patients with a history of gastro-oesophageal reflux symptoms and hiatal hernia, as defined by videofluorography combined with a water siphon test, underwent oesophagogastroduodenoscopy and multiple biopsies. Hiatal hernia was confirmed endoscopically in 99% of cases. The water siphon test was positive for reflux in 72% of cases. At endoscopy 42% of patients had oesophagitis and/or Barrett's oesophagus and 58% had no lesions. In the group without endoscopic lesions, at histology…
A novel minimally invasive, dorsolateral, tubular partial odontoidectomy and autologous bone augmentation to treat dens pseudarthrosis: cadaveric, 3D…
2017
OBJECTIVE The goal of this study was to demonstrate the clinical and technical nuances of a minimally invasive, dorsolateral, tubular approach for partial odontoidectomy, autologous bone augmentation, and temporary C1–2 fixation to treat dens pseudarthrosis. METHODS A cadaveric feasibility study, a 3D virtual reality reconstruction study, and the subsequent application of this approach in 2 clinical cases are reported. Eight procedures were completed in 4 human cadavers. A minimally invasive, dorsolateral, tubular approach for odontoidectomy was performed with the aid of a tubular retraction system, using a posterolateral incision and an oblique approach angle. Fluoroscopy and postprocedur…
[Esophageal digital videofluorography with water siphon test in the post-operative evaluation of the anti-reflux laparoscopic surgery].
2004
Background: In recent years digital videoefluorography (VFG) with water siphon test (WST) has been proposed just for diagnosing biatal bernia and/or gastroesophageal reflux. Patients and Methods: Fifteen patients undergone Laparoscopic Nissen (LN) for complicated GFRD associated to biatal bernia, were referred for VFG and WST in order to evaluate the functional results of surgery. At one- month videofluorographic control thirteen patients had just a minimal prolonged esophageal transit time hut only six of these had an early postoperative dysphagia, whereas at six montJh control the prolonged esophageal transit time was present in three patients two of which complained a very light dysphagi…
Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures
2013
The purpose of this study was to analyze the practicability and benefit of intraoperative C-arm computed tomography (CT) imaging in volar plate osteosynthesis of unstable distal radius fractures. During a 1 year period, intraoperative three dimensional (3D) imaging with the ARCADIS Orbic 3D was performed in addition to standard fluoroscopy in 51 cases. The volar angular stable plate oesteosyntheses were analyzed intraoperatively and, if necessary, improved immediately. The duration of the scan and radiation exposure dose were measured. On average, performance of the scan and analysis of the CT dataset took 6.7 minutes. In 31.3% of the surgeries a misplacement of screws was detected and cor…
Low-energy extracorporeal shock wave therapy for painful heel: a prospective controlled single-blind study.
1996
The aim of this prospective single-blind pilot study was to explore the pain-alleviating effect of low-energy extracorporeal shock wave therapy (ESWT) in painful heel associated with inferior calcaneal spurs. Thirty patients who suffered from persistent symptoms for more than 12 months qualified for low-energy ESWT and were assigned at random to two groups, real or simulated ESWT. Before beginning the treatment, any other therapy was stopped for a period of 6 weeks. The shock waves were applied by an experimental device allowing exact localization through an integrated fluoroscopy unit. Patients were treated three times at weekly intervals. Each time 1000 impulses of 0.06 mJ/mm2 were given …
Detection of coronary artery calcifications predicting coronary heart disease: comparison of fluoroscopy and spiral CT.
1998
The aim of this study was to evaluate the clinical relevance of coronary artery calcifications detected by spiral CT, congruence with fluoroscopy (FS) and coronary angiography, and comparison with studies reporting on application of double-helical CT and ultrafast CT. Forty patients underwent spiral CT (2-mm slice thickness, table feed 3 mm/s), coronary angiography, and FS (performed in the usual manner). Stenosis and calcifications were evaluated semiquantitatively. Nineteen patients suffering from a stenosis ≥ 75 % were verified at coronary angiography. All had coronary artery calcification on spiral CT. Fluoroscopy did not detect 8 of 19 patients with a stenosis ≥ 75 % (1 vessel: n = 1; …
Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Performance of Single Lead VDD Pacemakers
2002
WIEGAND, U.K.H., et al.: Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Perfor-mance of Single Lead VDD Pacemakers. Intermittent atrial undersensing is observed in a considerable percentage of patients with single lead VDD pacemakers. Analyzing the 2-year data of the Saphir Multicenter Follow-Up Study, the authors investigated predictors for the occurrence of undersensing. The study included 194 patients with high degree AV block who received a VDD pacemaker system with an identical sensing amplifier. Placement strategy of the atrial dipole was left to the discretion of the implanting physician. At the final position, atrial potential amplitudes were measured during deep …
Maintenance of Integrity of Upper Facet Joints during Simulated Percutaneous Pedicle Screw Insertion Using 2D versus 3D Planning
2019
Background No studies have directly and quantitatively compared two-dimensional (2D) and three-dimensional (3D) planning as applied during conventional percutaneous or navigated percutaneous pedicle screw placement. Study Aims This lumbar pedicle-based stabilization simulation study aimed to investigate the risk of upper facet joint violation (FJV) during posterior percutaneous pedicle screw placement with conventional 2D planning of screw implantation (as a model for fluoroscopically guided screws) compared with 3D planning (as used with navigation techniques). Methods The placement of monosegmental lumbar pedicle screws using the data sets of 250 consecutive patients was simulated. Conve…
Determination of optimal fluoroscopic angulations for aorto-coronary ostial interventions from coronary computed tomography angiography.
2020
Abstract Background An optimal aorto-coronary angiographic projection, characterized by an orthogonal visualization of the proximal coronary artery, is crucial for interventional success. We determined the distribution of optimal C-arm positions and assessed their feasibility by invasive coronary angiography. Methods Orthogonal aorto-coronary ostial angulations were determined in 310 CT data sets. In 100 patients undergoing subsequent invasive angiography, we assessed if the CT-predicted angulations were achievable by the C-arm system. If the predicted projection was not achievable due to mechanical constraints of the C-arm system, the most close, achievable angulation was determined. Patie…