Search results for "Foreign-body"

showing 10 items of 37 documents

Posterior chamber phakic intraocular lenses to correct high myopia: A comparative study between Staar and Adatomed models

2001

ABSTRACT PURPOSE: To determine the feasibility of using posterior chamber phakic intraocular lenses (PIOLs) to treat high myopia, comparing two different models, Staar and Adatomed. METHODS: Twenty-four eyes from 12 patients were studied prospectively. A phakic Staar IOL was implanted in one eye of each patient, and the other eye received a phakic Adatomed IOL. Patients with uveitis or ocular trauma prior to ocular surgery, diabetic retinopathy, or capsular pseudoexfoliation were excluded. The mean preoperative spherical equivalent refraction was -16.00 ± 5.05 D for the Staar group and -15.39 ± 2.83 D for the Adatomed group. Average follow-up was 32.4 months (range, 19 to 46 mo) for the Ada…

AdultMaleIntraocular pressureRefractive errormedicine.medical_specialtyAnterior subcapsular cataractVisual acuitygenetic structuresEye diseasemedicine.medical_treatmentLens Capsule CrystallineVisual AcuityIntraocular lensRefraction OcularPhakic intraocular lensCataractVision disorderPostoperative ComplicationsForeign-Body MigrationLens Implantation IntraocularLens CrystallineMyopiaHumansMedicineIntraocular PressureLenses Intraocularbusiness.industrymedicine.diseaseeye diseasesSurgeryOphthalmologyFeasibility StudiesFemaleSurgerysense organsmedicine.symptombusinessFollow-Up Studies
researchProduct

Otoneurological management of petrous apex cholesterol granuloma

2009

Objective: The aim of the study is to review the management of petrous apex cholesterol granuloma. The surgical approaches for drainage or total removal and the wait and see policy were analyzed, and outcomes were evaluated. Methods: Retrospective charts of 27 patients managed for petrous apex cholesterol granuloma with a minimum follow-up of 12 months were analyzed in a quartenary skull base center. Presenting symptoms and signs were recorded, and radiologic imaging was evaluated. Management options included wait and see policy and surgery by several approaches. Results: The mean age of patients affected by the lesion was 38.8 years. The mean follow-up was 56.7 months. Patients complained …

AdultMalemedicine.medical_specialtyAdolescentEpidermal CystDiagnosis DifferentialYoung AdultTrigeminal neuralgiaVertigomedicine.arterymedicineHumansChildpetrous apexRetrospective StudiesDiplopiabiologyPetrous Apexbusiness.industryGranuloma Foreign-Bodycholesterol granulomaInfratemporal fossaskull baseMiddle Agedmedicine.diseasebiology.organism_classificationMagnetic Resonance ImagingSurgeryArachnoid Cystsmedicine.anatomical_structureCholesterolTreatment OutcomeOtorhinolaryngologyDrainageFemaletemporal bonemedicine.symptomInternal carotid arteryBone DiseasesbusinessTomography X-Ray ComputedTinnitusHemifacial spasmFollow-Up StudiesPetrous Bone
researchProduct

Impact of Different Texture of Polypropylene Mesh on the Inflammatory Response

2008

Over the past decade, hernia surgery has undergone a considerable transformation with the use of prosthetic materials. The most used polypropylene meshes induce a rapid acute inflammatory response followed by chronic foreign body reaction. Many factors influence this response such as density, size, physical characteristics, different texture and porosity of each biomaterial. The aim of this study is to assess whether the implant of monofilament or multifilament meshes, in the inguinal hernioplasty, determine a different inflammatory response. Thirty-two male patients were included in the study and were randomly divided into two groups. In the first group (MO) inguinal hernioplasty was perf…

AdultMalemedicine.medical_specialtymedicine.medical_treatmentImmunologyUrologyHernia InguinalPolypropylenesProsthesisLeukocyte CountBasal (phylogenetics)medicineHumansImmunology and AllergyHerniaInflammationPharmacologyPain Postoperativebusiness.industryForeign-Body ReactionInterleukinVenous bloodMiddle AgedSurgical Meshmedicine.diseasePeripheralC-Reactive ProteinCytokinealpha 1-AntitrypsinCytokinesImplantbusinessInternational Journal of Immunopathology and Pharmacology
researchProduct

Tension-free hernia repair is associated with an increase in inflammatory response markers against the mesh.

2000

Abstract Background: The purpose of this study was to evaluate the involvement of inflammatory mediators in patients undergoing Lichtenstein tension-free hernioplasty (LH) using polypropylene prosthetic materials or conventional Bassini hernia repair (BH). Methods: Thirty patients male with unilateral inguinal hernia without complications or recurrence were included in this study. Randomly, patients underwent LH or BH. Peripheral venous bloods samples were collected 24 hours prior to surgery and then 6, 24, 48 and 168 hours postoperatively. Results: We present evidences that LH patients showed a higher increased serum level of fibrinogen, C-reactive protein, alpha-1-antitrypsin, and interle…

AdultMalemedicine.medical_treatmentInflammationHernia InguinalFibrinogenPolypropylenesProsthesis ImplantationLeukocyte CountPostoperative ComplicationsMedicineHumansHerniaPostoperative PeriodInflammationbiologybusiness.industryInterleukin-6Foreign-Body ReactionAlbuminFibrinogenGeneral MedicineMiddle AgedSurgical Meshmedicine.diseaseHernia repairPeripheralmedicine.anatomical_structureC-Reactive ProteinAnesthesiaalpha 1-Antitrypsinbiology.proteinAbdomenSurgerymedicine.symptombusinessCeruloplasminmedicine.drugAmerican journal of surgery
researchProduct

Impact of the line of sight on toric phakic intraocular lenses for hyperopia

2003

We present a hyperopic patient with a decentered line of sight in whom the residual refractive error after toric phakic intraocular lens (TP IOL) implantation was improved by displacement and individualized treatment. A 35-year-old woman presented with asthenopic complaints 2 months after bilateral TP IOL implantation and IOL rotation 4 weeks later. Examination revealed the line of sight to be nasally and inferiorly decentered in relation to the center of the pupil. A more nasal reenclavation of the TP IOL decreased the coma, and the uncorrected visual acuity was 20/20. We conclude that line of sight should be measured before TP IOL implantation, especially in hyperopic eyes.

AdultReoperationRefractive errormedicine.medical_specialtygenetic structuresEye diseasemedicine.medical_treatmentVision DisordersVisual AcuityComa (optics)Intraocular lensUncorrected visual acuityPhakic intraocular lensPupilVision disorderForeign-Body MigrationLens Implantation IntraocularOphthalmologyLens CrystallinemedicineHumansbusiness.industryAstigmatismCorneal TopographyPupilmedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaOptometryFemaleSurgeryAsthenopiasense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Complications of Poly Implant Prothèse breast implants: the current discussion

2013

Against the background of the current discussion about Poly Implant Prothèse (PIP, Seyne-sur-mer, France) breast implants, we want to present a case demonstrating the complications such as implant rupture, silicone dissemination and level III silicone lymphadenopathy. A 29-year-old woman with cosmetic breast augmentation with PIP implants 5 years previously showed a sensitive swelling in her right axilla and neck region. All tests to detect an infectious or lymphomatous lymphadenopathy were negative. After ultrasound and MRI, rupture of the right implant was assumed and multiple pathologically enlarged lymph nodes up to supraclavicular region were shown. An excision biopsy of one axillary l…

AdultReoperationmedicine.medical_specialtyAxillary lymph nodesBiopsyBreast ImplantsBiomedical EngineeringProsthesis DesignSilicone Gelschemistry.chemical_compoundSiliconeBiopsymedicineHumansBreast ImplantationLymphatic DiseasesBreast augmentationLymph nodeDevice Removalmedicine.diagnostic_testbusiness.industryForeign-Body ReactionGeneral MedicineProsthesis FailureSurgeryAxillaTreatment Outcomemedicine.anatomical_structurechemistryAxillaLymph Node ExcisionFemaleSurgeryLymph NodesLymphImplantbusinessExpert Review of Medical Devices
researchProduct

An In Vitro Phantom Study on the Role of the Bird-Beak Configuration in Endograft Infolding in the Aortic Arch.

2015

Purpose: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. Methods: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. Results: The bird-beak configuration with the greatest protr…

Aortic archModels AnatomicRadiology Nuclear Medicine and ImagingTime FactorsFlow modelPulsatile flowEndograftStent-graft oversizingAorta Thoracic030204 cardiovascular system & hematologyRotation0302 clinical medicineForeign-Body MigrationStentThoracic aortaBird-beak configurationmedicine.diagnostic_testEndovascular ProceduresGraft Occlusion VascularModels CardiovascularAnatomyIn vitro experimentProsthesis FailureBlood Vessel ProsthesiTreatment OutcomePulsatile FlowPatient-specific modelStentsCardiology and Cardiovascular MedicineHumanAortographyTime FactorThoracic endovascular aortic repairProsthesis DesignAortographyImaging phantom03 medical and health sciencesBlood Vessel Prosthesis ImplantationBlood vessel prosthesismedicine.arterymedicineHumansDisplacement (orthopedic surgery)HemodynamicEndovascular Procedurebusiness.industryHemodynamicsDisplacementStent-graft infoldingBlood Vessel ProsthesisSurgerybusinessTomography X-Ray Computed030217 neurology & neurosurgeryStent-graft collapseJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Histological Findings in Coil-packed Experimental Aneurysms 3 Months after Embolization

2002

ABSTRACT OBJECTIVE Knowledge regarding tissue reactions within coil-packed aneurysms is poor. The purpose of this study was to analyze histological changes in a chronic experimental bifurcation aneurysm model that might explain the protective effect of Guglielmi detachable coils. METHODS The aneurysms were produced by means of a venous graft pouch at a surgically created bifurcation of the carotid artery in the neck of rabbits. After 3 weeks, embolization with Guglielmi detachable coils was performed in the treatment group but not in the control group (seven rabbits each). At the time of embolization, six of seven treated aneurysms were completely occluded according to radiological criteria…

Carotid Artery DiseasesMalemedicine.medical_specialtymedicine.medical_treatmentGross examinationAneurysmmedicineAnimalsEmbolizationForeign BodiesObjective knowledgemedicine.diagnostic_testbusiness.industryVascular diseaseForeign-Body ReactionGranulation tissueIntracranial Aneurysmmedicine.diseaseEmbolization TherapeuticSurgeryCarotid Arteriesmedicine.anatomical_structureAngiographyGranulation TissueSurgeryRabbitsNeurology (clinical)businessNeurosurgery
researchProduct

Multinucleated giant cells in the implant bed of bone substitutes are foreign body giant cells-New insights into the material-mediated healing process

2017

In addition to macrophages, multinucleated giant cells (MNGCs) are involved in the tissue reaction to a variety of biomaterials. Especially in the case of bone substitute materials it has been assumed that the MNGCs are osteoclasts, based on the chemical and physical similarity of many materials to the calcified matrix and the bony environment in which they are used. However, many studies indicate that these cells belong to the cell line of the foreign body giant cells (FBGCs), which are of "inflammatory origin", although they have been shown to possess both a pro- and also anti-inflammatory phenotype. Moreover, no information is available about their role in the tissue reaction to bone sub…

Foreign-body giant cellMaterials sciencebiologyRegeneration (biology)IntegrinMetals and AlloysBiomedical Engineering030206 dentistry02 engineering and technologyMatrix (biology)021001 nanoscience & nanotechnologyBone tissueCell biologyBiomaterials03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureCell cultureGiant cellCeramics and Compositesmedicinebiology.protein0210 nano-technologyProcess (anatomy)Biomedical engineeringJournal of Biomedical Materials Research Part A
researchProduct

Small-sized granules of biphasic bone substitutes support fast implant bed vascularization

2015

The present study investigated the influence of granule size of 2 biphasic bone substitutes (BoneCeramic® 400-700 μm and 500-1000 μm) on the induction of multinucleated giant cells (MNGCs) and implant bed vascularization in a subcutaneous implantation model in rats. Furthermore, degradation mechanisms and particle phagocytosis of both materials were examined by transmission electron microscopy (TEM). Both granule types induced tissue reactions involving primarily mononuclear cells and only small numbers of MNGCs. Higher numbers of MNGCs were detected in the group with small granules starting on day 30, while higher vascularization was observed only at day 10 in this group. TEM analysis reve…

Foreign-body giant cellPathologymedicine.medical_specialtyMaterials sciencebiphasic bone substitutePhagocytosisBiomedical EngineeringNeovascularization PhysiologicMedicine (miscellaneous)Giant CellsPeripheral blood mononuclear cellBone and BonesBiomaterialsMiceMultinucleatevascularizationMaterials TestingmedicineAnimalsParticle SizedegradationGranule (cell biology)granule sizephagocytosisGeneral MedicineRatsCell biologyDisease Models AnimalTransmission electron microscopyGiant cellBone SubstitutesLeukocytes MononuclearMicroscopy Electron ScanningBoneCeramicFemaleHydroxyapatitesImplantmultinucleated giant cellsResearch PaperBiomatter
researchProduct