Search results for "Foreign-body"
showing 10 items of 37 documents
Posterior chamber phakic intraocular lenses to correct high myopia: A comparative study between Staar and Adatomed models
2001
ABSTRACT PURPOSE: To determine the feasibility of using posterior chamber phakic intraocular lenses (PIOLs) to treat high myopia, comparing two different models, Staar and Adatomed. METHODS: Twenty-four eyes from 12 patients were studied prospectively. A phakic Staar IOL was implanted in one eye of each patient, and the other eye received a phakic Adatomed IOL. Patients with uveitis or ocular trauma prior to ocular surgery, diabetic retinopathy, or capsular pseudoexfoliation were excluded. The mean preoperative spherical equivalent refraction was -16.00 ± 5.05 D for the Staar group and -15.39 ± 2.83 D for the Adatomed group. Average follow-up was 32.4 months (range, 19 to 46 mo) for the Ada…
Otoneurological management of petrous apex cholesterol granuloma
2009
Objective: The aim of the study is to review the management of petrous apex cholesterol granuloma. The surgical approaches for drainage or total removal and the wait and see policy were analyzed, and outcomes were evaluated. Methods: Retrospective charts of 27 patients managed for petrous apex cholesterol granuloma with a minimum follow-up of 12 months were analyzed in a quartenary skull base center. Presenting symptoms and signs were recorded, and radiologic imaging was evaluated. Management options included wait and see policy and surgery by several approaches. Results: The mean age of patients affected by the lesion was 38.8 years. The mean follow-up was 56.7 months. Patients complained …
Impact of Different Texture of Polypropylene Mesh on the Inflammatory Response
2008
Over the past decade, hernia surgery has undergone a considerable transformation with the use of prosthetic materials. The most used polypropylene meshes induce a rapid acute inflammatory response followed by chronic foreign body reaction. Many factors influence this response such as density, size, physical characteristics, different texture and porosity of each biomaterial. The aim of this study is to assess whether the implant of monofilament or multifilament meshes, in the inguinal hernioplasty, determine a different inflammatory response. Thirty-two male patients were included in the study and were randomly divided into two groups. In the first group (MO) inguinal hernioplasty was perf…
Tension-free hernia repair is associated with an increase in inflammatory response markers against the mesh.
2000
Abstract Background: The purpose of this study was to evaluate the involvement of inflammatory mediators in patients undergoing Lichtenstein tension-free hernioplasty (LH) using polypropylene prosthetic materials or conventional Bassini hernia repair (BH). Methods: Thirty patients male with unilateral inguinal hernia without complications or recurrence were included in this study. Randomly, patients underwent LH or BH. Peripheral venous bloods samples were collected 24 hours prior to surgery and then 6, 24, 48 and 168 hours postoperatively. Results: We present evidences that LH patients showed a higher increased serum level of fibrinogen, C-reactive protein, alpha-1-antitrypsin, and interle…
Impact of the line of sight on toric phakic intraocular lenses for hyperopia
2003
We present a hyperopic patient with a decentered line of sight in whom the residual refractive error after toric phakic intraocular lens (TP IOL) implantation was improved by displacement and individualized treatment. A 35-year-old woman presented with asthenopic complaints 2 months after bilateral TP IOL implantation and IOL rotation 4 weeks later. Examination revealed the line of sight to be nasally and inferiorly decentered in relation to the center of the pupil. A more nasal reenclavation of the TP IOL decreased the coma, and the uncorrected visual acuity was 20/20. We conclude that line of sight should be measured before TP IOL implantation, especially in hyperopic eyes.
Complications of Poly Implant Prothèse breast implants: the current discussion
2013
Against the background of the current discussion about Poly Implant Prothèse (PIP, Seyne-sur-mer, France) breast implants, we want to present a case demonstrating the complications such as implant rupture, silicone dissemination and level III silicone lymphadenopathy. A 29-year-old woman with cosmetic breast augmentation with PIP implants 5 years previously showed a sensitive swelling in her right axilla and neck region. All tests to detect an infectious or lymphomatous lymphadenopathy were negative. After ultrasound and MRI, rupture of the right implant was assumed and multiple pathologically enlarged lymph nodes up to supraclavicular region were shown. An excision biopsy of one axillary l…
An In Vitro Phantom Study on the Role of the Bird-Beak Configuration in Endograft Infolding in the Aortic Arch.
2015
Purpose: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. Methods: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. Results: The bird-beak configuration with the greatest protr…
Histological Findings in Coil-packed Experimental Aneurysms 3 Months after Embolization
2002
ABSTRACT OBJECTIVE Knowledge regarding tissue reactions within coil-packed aneurysms is poor. The purpose of this study was to analyze histological changes in a chronic experimental bifurcation aneurysm model that might explain the protective effect of Guglielmi detachable coils. METHODS The aneurysms were produced by means of a venous graft pouch at a surgically created bifurcation of the carotid artery in the neck of rabbits. After 3 weeks, embolization with Guglielmi detachable coils was performed in the treatment group but not in the control group (seven rabbits each). At the time of embolization, six of seven treated aneurysms were completely occluded according to radiological criteria…
Multinucleated giant cells in the implant bed of bone substitutes are foreign body giant cells-New insights into the material-mediated healing process
2017
In addition to macrophages, multinucleated giant cells (MNGCs) are involved in the tissue reaction to a variety of biomaterials. Especially in the case of bone substitute materials it has been assumed that the MNGCs are osteoclasts, based on the chemical and physical similarity of many materials to the calcified matrix and the bony environment in which they are used. However, many studies indicate that these cells belong to the cell line of the foreign body giant cells (FBGCs), which are of "inflammatory origin", although they have been shown to possess both a pro- and also anti-inflammatory phenotype. Moreover, no information is available about their role in the tissue reaction to bone sub…
Small-sized granules of biphasic bone substitutes support fast implant bed vascularization
2015
The present study investigated the influence of granule size of 2 biphasic bone substitutes (BoneCeramic® 400-700 μm and 500-1000 μm) on the induction of multinucleated giant cells (MNGCs) and implant bed vascularization in a subcutaneous implantation model in rats. Furthermore, degradation mechanisms and particle phagocytosis of both materials were examined by transmission electron microscopy (TEM). Both granule types induced tissue reactions involving primarily mononuclear cells and only small numbers of MNGCs. Higher numbers of MNGCs were detected in the group with small granules starting on day 30, while higher vascularization was observed only at day 10 in this group. TEM analysis reve…