First absolute mass measurements of short-lived isotopes
1987
Absolute mass measurements of short-lived isotopes have been performed at the on-line mass separator ISOLDE at CERN by determining the cyclotron frequencies of ions confined in a Penning trap. The cyclotron frequencies for77,78,85,86,88Rb and88Sr ions could be determined with a resolving power of 3×105 and an accuracy of better than 10−6, which corresponds to 100 keV for massA=100. The shortest-lived isotope under investigation was77Rb with a half-life of 3.7 min. The resonances obtained for the isobars88Rb and88Sr were clearly resolved.
Diagnostics of a charge breeder electron cyclotron resonance ion source helium plasma with the injection ofNa231+ions
2016
This work describes the utilization of an injected 23Na1+ ion beam as a diagnostics of the helium plasma of a charge breeder electron cyclotron resonance ion source. The obtained data allows estimating the upper limit for the ion-ion collision mean-free path of the incident sodium ions, the lower limit of ion-ion collision frequencies for all charge states of the sodium ions and the lower limit of the helium plasma density. The ion-ion collision frequencies of high charge state ions are shown to be at least on the order of 1–10 MHz and the plasma density is estimated to be on the order of 1011 cm−3 or higher. The experimental results are compared to simulations of the 23Na1+ capture into t…
Fourier transform-ion cyclotron resonance mass spectrometry — A new tool for measuring highly charged ions in an electron beam ion trap
1995
Abstract Fourier transform-ion cyclotron mass spectrometry has been applied to the study of highly charged ions produced and confined in an electron beam ion trap. Measurements of the relative ion abundance of hydrogenlike and bare krypton ions were made and compared to the abundance ratios determined with standard X-ray techniques. Good agreement was found establishing the reliability of the method as a new tool in highly charged ion research.
The interconversion of the radial motional modes of an ion in a Penning trap mass spectrometer by 4n-polar external radio frequency fields (n= 1,2,3,…
2013
In Penning trap mass spectrometry ion masses are determined by measuring the free cyclotron frequency via the resonant conversion of the magnetron into the cyclotron motional mode, induced by the interaction with an external radio-frequency field. With octupolar rf-fields of frequency the mass resolution has been improved by more than an order of magnitude as compared to conventional quadrupolar fields of frequency and with the same pulse duration. This result raises the question what one might expect from using 12-polar rf-fields with frequency or even 16-polar rf-fields with frequency . In this paper the theoretical model for the interconversion of the radial modes by quadrupolar and octu…
Dynamic regimes of cyclotron instability in the afterglow mode of minimum-Belectron cyclotron resonance ion source plasma
2016
The paper is concerned with the dynamic regimes of cyclotron instabilities in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source operated in pulsed mode. The instability appears in decaying ion source plasma shortly (1–10 ms) after switching off the microwave radiation of the klystron, and manifests itself in the form of powerful pulses of electromagnetic emission associated with precipitation of high-energy electrons along the magnetic field lines. Recently it was shown that this plasma instability causes perturbations of the extracted ion current, which limits the performance of the ion source and generates strong bursts of bremsstrahlung emission. In this artic…
The Mainz Cluster Trap
1999
When cluster ions are stored by electromagnetic forces they are available in the gas phase for extended preparations and investigations. Over the last decade a Penning trap (Ion Cyclotron Resonance) apparatus has been constructed and further developed with respect to metal cluster research at the Institute of Physics at Mainz. It allows to capture and accumulate ion bunches injected from an external cluster source and to manipulate the ions’ motion, i.e. select and center the clusters of interest. The interactions that have been investigated include those with inert and chemically reactive gases, photons and electrons. Multiple mass spectrometric steps such as fragment ion selection can be …
Position-sensitive ion detection in precision Penning trap mass spectrometry
2009
A commercial, position-sensitive ion detector was used for the first time for the time-of-flight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its implementation in a Penning trap mass spectrometer will be presented. In addition, simulations and experimental studies concerning the observation of ions ejected from a Penning trap are described. This will allow for a precise monitoring of the state of ion motion in the trap.
Beam current oscillations driven by cyclotron instabilities in a minimum-Belectron cyclotron resonance ion source plasma
2014
Experimental observation of cyclotron instabilities in a minimum-B confined electron cyclotron resonance ion source plasma is reported. The instabilities are associated with strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic ms-scale oscillation of the extracted beam currents. Such non-linear effects are detrimental for the confinement of highly charged ions due to plasma perturbations at shorter periodic intervals in comparison with their production time. It is shown that the repetition rate of the periodic instabilities in oxygen plasmas increases with increasing magnetic field strength and microwave power and decreases with increasi…
Plasma instability in the afterglow of electron cyclotron resonance discharge sustained in a mirror trap
2012
The work presented in this article is devoted to time-resolved diagnostics of non-linear effects observed during the afterglow plasma decay of a 14 GHz electron cyclotron resonance ion source operated in pulsed mode. Plasma instabilities that cause perturbations of the extracted ion current during the decay were observed and studied. It is shown that these perturbations are associated with precipitation of high energy electrons along the magnetic field lines and strong bursts of bremsstrahlung emission. The effect of ion source settings on the onset of the observed instabilities was investigated. Based on the experimental data and estimated plasma properties, it is assumed that the instabil…
Oscillations of ECR ion source beam current along the beam transport of the JYFL K-130 cyclotron
2013
A versatile measurement system has been developed to study the temporal characteristics of ion beams in millisecond time scale. The system is composed of data acquisition hardware and LabVIEW based measurement and analysis program. The measurement system and ion beam current oscillation results measured with a 14 GHz AECR-U type ion source at University of Jyv"askyl"a, Department of Physics (JYFL), are presented. It is shown that the ion beams exhibit periodic current fluctuations at frequencies from 100 Hz to 1.5 kHz with amplitudes ranging from 1 to 65 percent of the average beam current. It is argued that these oscillations originate from the ion source plasma since their characteristics…