Search results for "Fourier transform"
showing 10 items of 1138 documents
Theory of quadrupole detection fourier transform-ion cyclotron resonance
1991
Abstract The theoretical basis of the recently introduced quadrupole detection Fourier transform-ion cyclotron resonance technique is developed by use of the concept of image charges induced in the detection electrodes. The appearance of resonances at frequencies 2ω+, 2ω−, (ω+ + ω−) and (ω+ − ω−) is explained. The new method is compared with the standard (dipole) detection scheme. Techniques are suggested allowing the simultaneous determination of all resonance frequencies ω+ (perturbed, or reduced, cyclotron frequency), ω− (magnetron frequency) and ωz (trapping frequency).
The elliptical Penning trap: Experimental investigations and simulations
2008
Abstract The application of an additional azimuthal quadrupolar electrostatic field to a Penning trap leads to a field configuration referred to as an elliptical Penning trap. The resulting changes of the radial ion motions have been investigated experimentally and by use of simulations. The eigenfrequencies, i.e., the magnetron frequency ω ˜ − and the reduced cyclotron frequency ω ˜ + , are found to be shifted with respect to those of the standard Penning trap ω − , ω + , respectively. As the shift of the magnetron frequency ω ˜ − is larger than that of the reduced cyclotron frequency ω ˜ + their sum ω ˜ + + ω ˜ − is also a function of the ellipticity and no longer equal to the cyclotron f…
Mass measurements of very high accuracy by time-of-flight ion cyclotron resonance of ions injected into a penning trap
1989
Abstract The possibility of absolute mass measurements using time-of-flight detection of ion cyclotron resonance on ions injected into a Penning trap has been demonstrated. Resolving powers of 2 million have been achieved, with accuracies of about 0.5 ppm. Absolute accuracy is obtained by direct observation of the sum frequency of the cyclotron and the magnetron motions through the use of an azimuthal quadrupole r.f. field to transform initial magnetron motion into cyclotron motion. Imperfections of the Penning trap leading to systematic errors are discussed. The system has been designed specifically to measure the masses of radionuclides produced at the on-line isotope separator ISOLDE. Wi…
Damping effects in Penning trap mass spectrometry
2011
Abstract Collisions of ions with residual gas atoms in a Penning trap can have a strong influence on the trajectories of the ions, depending on the atom species and the gas pressure. We report on investigations of damping effects in time-of-flight ion-cyclotron resonance mass spectrometry with the Penning trap mass spectrometers ISOLTRAP at ISOLDE/CERN (Geneva, Switzerland) and SHIPTRAP at GSI (Darmstadt, Germany). The work focuses on the interconversion of the magnetron and cyclotron motional modes, in particular the modification of the resonance profiles for quadrupolar excitation due to the damping effect of the residual gas. Extensive experiments have been performed with standard and Ra…
Photocatalytic degradation of 4-Nitrophenol by g-C3N4-MCy: Mechanism study and kinetic modeling
2021
Abstract A graphitic carbon nitride (g-C3N4-MCy) photocatalyst was prepared by thermal condensation of melamine and cyanuric acid with equal proportions. The photocatalyst was characterized by Fourier transform infrared spectroscopy (FTIR), Specific surface area (SSA), X-ray diffraction (XRD), Field Emission Scanning Electron Microscope (FESEM), Transmission electron microscope (TEM), and DRS–UV–Vis spectroscopic methods. We studied the photo-degradation kinetics of 4-nitrophenol using a g-C3N4-MCy. Four parameters were applied including initial concentration of 4-nitrophenol, amount of catalyst, dissolved oxygen content, and photon flux. The reaction rate constant was shown to be correlate…
Porous materials as delivery and protective agents for Vitamin A
2016
The suitability of porous materials to immobilize and release under control bioactive molecules prompted us to design and study delivery systems of Vitamin A (VitA). This molecule, relevant in several physiological functions, is easily oxidized. Commercial VitA was immobilized in two different clays, montmorillonite K-10 (MMT) and sepiolite (SEP), and in MCM-41, by impregnation. Characterization of the resulting hybrid materials by XRD, FTIR and 13C and 29Si (MAS) NMR spectroscopies revealed its presence. The photo-stability tests showed decreased degradation of VitA in the clays, compared to MCM-41 and the pure VitA, while thermostability is observed until ∼100 °C. The kinetics of the rele…
Extended Fourier-transform spectroscopy studies and deperturbation analysis of the spin-orbit coupled A1Σ+ and b3Π states in RbCs.
2014
The article presents a study of the strongly spin-orbit coupled singlet A(1)Σ(+) and triplet b(3)Π states of the RbCs molecule, which provide an efficient optical path to transfer ultracold molecules to their rovibrational ground state. Fourier-transform A(1)Σ(+) - b(3)Π → X(1)Σ(+) and (4)(1)Σ(+) → A(1)Σ(+) - b(3)Π laser-induced fluorescence (LIF) spectra were recorded for the natural mixture of the (85)Rb(133)Cs and (87)Rb(133)Cs isotopologues produced in a heat pipe oven. Overall 8730 rovibronic term values of A(1)Σ(+) and b(3)Π states were determined with an uncertainty of 0.01 cm(-1) in the energy range [9012, 14087] cm(-1), covering rotational quantum numbers J ∈ [6, 324]. An energy-ba…
On-line vapor-phase generation combined with Fourier transform infrared spectrometry
2008
We present a critical review of on-line vapor-phase generation combined with Fourier transform infrared spectrometry for detection. We discuss different experimental approaches developed for generating the vapor phase based on different principles (e.g., thermal volatilization, acid-base, redox reaction and covalent hydride generation). Using examples of applications, we try to demonstrate the analytical potential of on-line vapor-phase generation in vibrational spectrometry in order to improve the selectivity and the sensitivity of the measurement step and to make environmentally-friendly procedures available for problem solving in the analytical laboratory. We pay special attention to int…
Various types of polysiloxanes studied by positron annihilation lifetime spectroscopy
2014
Abstract In the work, linear poly(vinylsiloxanes) with regular distributions of vinyl groups along chains, the networks obtained by their hydrosilylation with various hydrogensiloxanes, products of pyrolysis of such networks as well as the networks prepared via reaction of low-molecular siloxanes have been studied by positron anihilation lifetime spectroscopy (PALS). Based on free volume sizes determined by this method, relations between cross-link densities in the investigated systems have been established. They have been compared with the results of swelling experiments conducted in the work and to efficiency of cross-linking reaction evaluated in our previous FTIR investigations of the s…
The infrared and Raman spectra of solid tridehydropeptides : influence of ΔAla and ΔPhe on the spectral profile
2012
Abstract A series of solid tripeptides Boc-Gly-X-Gly-OMe (X = dehydroalanine (ΔAla), dehydrophenylalanine (ΔPhe)) was investigated by Raman scattering and Fourier transform infrared spectra to examine the conformational marker bands of the unsaturated residue. The observed fundamental modes gave us the opportunity to analyze structural features that change due to the substitution of Ala by ΔAla and due to the different spatial arrangement of ΔPhe ( Z and E isomers). In addition, we showed the alteration of the spectral profile when the large size residue (Phe) is introduced into the backbone of the peptide with ΔPhe (in Boc-Gly-Δ (Z) Phe-Phe-OMe). The frequency ranges of interest included t…