Search results for "Fourier transform"

showing 10 items of 1138 documents

Low-cost set-up for Fourier-transform infrared spectroscopy in diamond anvil cell from 4000 to 400 cm−1

2011

An experimental set-up for Fourier-transform infrared (FTIR) studies at high pressure in the mid-IR region (400–4000 cm−1) is constructed using a compact TEO-400 FTIR interferometer module and an external microscopic optical bench with cassegrain focusing objectives. Cassegrain-type reflective objectives act as an excellent beam condenser that facilitates the interfacing between FTIR spectrometer and diamond anvil cell. This set-up is capable of recording transmission and reflection infrared spectra at high pressure. Preliminary results are reported both in the reflection (pressure dependence of polar phonons in CuWO4) and transmission configuration (polarized light absorption of polar phon…

Chemistrybusiness.industryInfraredCondenser (optics)Infrared spectroscopyCondensed Matter PhysicsFourier transform spectroscopyDiamond anvil cellCondensed Matter::Materials ScienceOpticsThermal infrared spectroscopyFourier transform infrared spectroscopybusinessAbsorption (electromagnetic radiation)High Pressure Research
researchProduct

Microwave emission related to cyclotron instabilities in a minimum-Belectron cyclotron resonance ion source plasma

2015

Electron cyclotron resonance ion sources (ECRIS) have been essential in the research and applications of nuclear physics over the past 40 years. They are extensively used in a wide range of large-scale accelerator facilities for the production of highly charged heavy ion beams of stable and radioactive elements. ECRISs are susceptible to kinetic instabilities due to resonance heating mechanism leading to anisotropic electron velocity distribution function. Instabilities of cyclotron type are a proven cause of frequently observed periodic bursts of 'hot' electrons and bremsstrahlung, accompanied with emission of microwave radiation and followed by considerable drop of multiply charged ions c…

ChemistrylawWaves in plasmasCyclotronCyclotron resonanceBremsstrahlungAtomic physicsCondensed Matter PhysicsIon cyclotron resonanceIon sourceElectron cyclotron resonanceFourier transform ion cyclotron resonancelaw.inventionPlasma Sources Science and Technology
researchProduct

On-line gradient liquid chromatography–Fourier transform infrared spectrometry determination of sugars in beverages using chemometric background corr…

2008

Abstract An on-line gradient reversed phase liquid chromatography–Fourier transform infrared spectrometry (LC–FTIR) method was developed for the determination of fructose, glucose, sucrose and maltose in beverages. Improved chromatographic resolution was obtained using a linear gradient from 75 to 55% (v/v) acetonitrile in water in 15 min. Changes in the background spectra were corrected employing “univariate background correction based on the use of a reference spectra matrix” (UBC-RSM) and using the ratio of absorbance (AR) at 2256 and 2253 cm −1 for the identification of the eluent spectra within the RSM. The method provided limits of detection in the order of 0.75 mg ml −1 . The precisi…

ChemometricsMatrix (chemical analysis)Detection limitColumn chromatographyChromatographyResolution (mass spectrometry)ChemistryAnalytical chemistryInfrared spectroscopyReversed-phase chromatographyFourier transform spectroscopyAnalytical ChemistryTalanta
researchProduct

Quantitative Analysis, Infrared

2000

In this article, after reviewing the different mathematical methods used in quantification we will describe and discuss their respective advantages and inconveniences. First of all, different examples of applications of infrared (IR) spectroscopy, used with or without other analytical chemistry methods, will be presented. Some examples of direct quantitative analysis in food analysis will be reviewed: lipids (measurement of unsaturation degrees, lipids determination), carbohydrates, proteins (secondary structures, quantitative analysis). We will also focus on original examples of the use of IR spectroscopy combined with enzymes. Secondly, some examples of Fourier transform infrared (FTIR) a…

Chemometricssymbols.namesakeFourier transformInfraredChemistryAnalytical chemistrysymbolsInfrared spectroscopyBiochemical engineeringFourier transform infrared spectroscopySpectroscopyQuantitative analysis (chemistry)Food Analysis
researchProduct

Using ATR-FTIR Spectroscopy To Design Active Antimicrobial Food Packaging Structures Based on High Molecular Weight Chitosan Polysaccharide

2007

ATR-FTIR spectroscopy has been used in this study to characterize the molecular mechanisms and kinetic processes that take place when a chitosonium acetate thin coating is put in contact with water solutions, Staphylococcus aureus solutions, microbial nutrient solutions, and with a high water activity TSA hydrogel medium to simulate the effect of direct contact with high moisture foods such as fresh meats, fish, and seafood products or beverages. The results of this work suggest that the biocide carboxylate groups that form when chitosan is cast from acetic acid solutions are being continuously evaporated from the formed film in the form of acetic acid (mechanism I) in the presence of envir…

ChitosanBiocideTime FactorsMoistureWater activityFood PackagingActive packagingGeneral ChemistryMolecular WeightChitosanFood packagingchemistry.chemical_compoundAcetic acidAnti-Infective AgentschemistryChemical engineeringPolysaccharidesSpectroscopy Fourier Transform InfraredOrganic chemistryFourier transform infrared spectroscopyGeneral Agricultural and Biological SciencesJournal of Agricultural and Food Chemistry
researchProduct

Influence of synthesis conditions on the performance of chitosan–Heteropolyacid complexes as membranes for low temperature H2–O2 fuel cell

2015

Flat, free-standing chitosan/phosphotungstic acid (PTA) polyelectrolyte membranes were prepared by in-situ ionotropic gelation process at room temperature on porous alumina support firstly impregnated by H3PW12O40. Scanning electron microscopy revealed the formation of compact and homogeneous membranes, whose thickness resulted to be dependent on chitosan concentration and reticulation time. X-ray diffraction and Fourier transform infrared spectroscopy (FTIR) evidenced the formation of almost amorphous membrane without appreciable concentration of not protonated NH2 groups and PTA3- ions with preserved Keggin structure. Membranes were tested as proton conductor in low temperature H2-O2 fuel…

ChitosanMaterials scienceProtonconductingRenewable Energy Sustainability and the EnvironmentScanning electron microscopeAnalytical chemistryEnergy Engineering and Power TechnologyHeteropolyacidCondensed Matter PhysicH<inf>2</inf>-O<inf>2</inf> PEMCFCondensed Matter PhysicsElectrochemistryPolyelectrolyteComposite membranechemistry.chemical_compoundKeggin structureSettore ING-IND/23 - Chimica Fisica ApplicataFuel TechnologyMembranechemistryChemical engineeringChitosanHeteropolyacidComposite membraneProton conducting H2 O2 PEMCFPhosphotungstic acidFourier transform infrared spectroscopyProton conductorInternational Journal of Hydrogen Energy
researchProduct

Ab initio calculations and vibrational spectroscopy on the phenylenediamine isomers

1998

Molecular orbital calculations at HF and MP2 levels have been performed using the 6-3IG** basis set for full geometry optimization of the phenylenediamine isomers. Our results show that only a transoid conformer is found for o-phenylenediamine, whereas cis and trans conformers exist for m- and p-phenylenediamine. Vibrational normal modes have been also analyzed for the gas phase and in chloroform solution, and compared with experimental data we have obtained using FTIR spectroscopy. © 1998 Elsevier Science B.V.

ChloroformChemistryInfrared spectroscopyCondensed Matter PhysicsBiochemistrychemistry.chemical_compoundAb initio quantum chemistry methodsComputational chemistryPhysical chemistryFTIR spectroscopy Geometry optimization Vibrational mode analysisMolecular orbitalPhysical and Theoretical ChemistryFourier transform infrared spectroscopyConformational isomerismCis–trans isomerismBasis set
researchProduct

Biogenic synthesis of palladium nanoparticles using Pulicaria glutinosa extract and their catalytic activity towards the Suzuki coupling reaction.

2014

Green synthesis of nanomaterials finds the edge over chemical methods due to its environmental compatibility. Herein, we report a facile and eco-friendly method for the synthesis of palladium (Pd) nanoparticles (NPs) using an aqueous solution of Pulicaria glutinosa, a plant widely found in a large region of Saudi Arabia, as a bioreductant. The as-prepared Pd NPs were characterized using ultraviolet-visible (UV-vis) spectroscopy, powder X-ray diffraction (XRD), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDX), and Fourier transform-infrared spectroscopy (FT-IR). The hydroxyl groups of the plant extract (PE) molecules were found mainly responsible for the red…

Chromatography GasMagnetic Resonance SpectroscopyStereochemistrychemistry.chemical_elementNanoparticleLigandsCatalysisCatalysisNanomaterialsPulicariaInorganic ChemistrySuzuki reactionMicroscopy Electron TransmissionX-Ray DiffractionSpectroscopy Fourier Transform InfraredMoleculeAqueous solutionChemistryPlant ExtractsX-RaysTemperatureGreen Chemistry TechnologyTransmission electron microscopyNanoparticlesSpectrophotometry UltravioletPalladiumNuclear chemistryPalladiumBromobenzenesDalton transactions (Cambridge, England : 2003)
researchProduct

Gas chromatography-fourier transform infrared spectrometry of fatty acids: New Applications with a direct deposition interface

1998

Infrared spectroscopy is a suitable spectroscopic method to differentiate geometric Z and E isomers of unsaturated compounds. A direct-deposition Fourier transform infrared spectrometer (FTIR), coupled to a gas chromatograph, was used successfully to analyze with a high sensitivity traces of C18:1 fatty acid methyl ester (FAME) isomers. It could also conclusively distinguish between isomers of conjugated diunsaturated FAME. The achievable sensitivity of this direct-deposition device makes possible accurate FAME mixture analyses that are not currently attainable with the more conventional light-pipe interface.

Chromatography010405 organic chemistryChemistryGeneral Chemical Engineering[SDV]Life Sciences [q-bio]010401 analytical chemistryOrganic ChemistryAnalytical chemistryInfrared spectroscopyTRANSFORMEE DE FOURRIERConjugated system01 natural sciences0104 chemical sciences[SDV] Life Sciences [q-bio]chemistry.chemical_compoundsymbols.namesakeFourier transformsymbolsGas chromatographyFourier transform infrared spectroscopyCis–trans isomerismUnsaturated fatty acidFatty acid methyl esterComputingMilieux_MISCELLANEOUS
researchProduct

Application of point-to-point matching algorithms for background correction in on-line liquid chromatography–Fourier transform infrared spectrometry …

2009

A new background correction method for the on-line coupling of gradient liquid chromatography and Fourier transform infrared spectrometry has been developed. It is based on the use of a point-to-point matching algorithm that compares the absorption spectra of the sample data set with those of a previously recorded reference data set in order to select an appropriate reference spectrum. The spectral range used for the point-to-point comparison is selected with minimal user-interaction, thus facilitating considerably the application of the whole method. The background correction method has been successfully tested on a chromatographic separation of four nitrophenols running acetonitrile (0.08…

ChromatographyAbsorption spectroscopyChemistryReference data (financial markets)Analytical chemistryInfrared spectroscopyFourier transform spectroscopyAnalytical ChemistryNitrophenolschemistry.chemical_compoundSpectroscopy Fourier Transform InfraredBackground Correction MethodFourier transform infrared spectroscopySpectroscopyAcetonitrileAlgorithmsChromatography LiquidTalanta
researchProduct