Search results for "Fourier transform"
showing 10 items of 1138 documents
Nutritional parameters of commercially available milk samples by FTIR and chemometric techniques
2004
Abstract A chemometric study on the prediction of the main nutritional aspects of milk has been carried out by using fourier transform infrared spectroscopy (FTIR) attenuated total reflectance (ATR) measurements of commercially available milk samples of different types. Whole, semi and skimmed milks, enriched or not with calcium, vitamins or modified by alteration of lipid or sugar composition were considered. After evaluating different strategies for data acquisition and ATR cleaning between samples, hierarchical cluster analysis (HCA) was carried out for classification of samples in order to choose the calibration set. The prediction capabilities of partial least squares (PLS) data treatm…
FT-IR quantitative analysis of solvent mixtures by the constant ratio method
1999
Abstract An analytical methodology to quantify compounds in complex mixtures by FTIR spectroscopy is proposed and the “Constant Ratio Method” (CRM) was developed. The addition of a standard to the sample allows us to establish a constant KMS characteristic of the Analyte/Standard system which can be employed as a quantification factor of the analyte in different samples . In the proposed method the measurements are independent of optical path length. This method has been successfully applied to quantify butylacetate and toluene in binary and tertiary samples and tertiary mixtures. Butylacetate/toluene/nujol have been resolved employing valeronitrile as standard, obtaining values for relativ…
Procedure for automated background correction in flow systems with infrared spectroscopic detection and changing liquid-phase composition
2009
This paper describes a partial least squares (PLS) based automatic procedure to correct for changes in the spectral contribution of the solvent or solvent mixtures from solute spectra recorded in these solvents. The procedure was developed for successful on-line Fourier transform infrared (FT-IR) detection in gradient high-performance liquid chromatography (HPLC) separations. It requires a reference FT-IR data set containing all possible combinations of the expected variation in solvent composition. Furthermore, a spectral region ( A) in these spectra is required where the solvents show absorption but the analytes do not. This is the case for the system ACN:H2O, an often-applied solvent mi…
Identification and determination of synthetic cannabinoids in herbal products by dry film attenuated total reflectance-infrared spectroscopy.
2017
A new procedure has been developed for the identification and quantitative determination of synthetic cannabinoids in illicit herbal preparations. The methodology is based on the use of attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) measurement of sample extracts with 2-propanol drying 5µL of the extracts onto the ATR crystal. The qualitative identification was carried out on the 2-propanol extract after identification of the herbal matrix, followed by its subtraction and using a cut-off criterion of 75%. Quantitative determination was made by univariate calibration using the absorbance of the band located at 1520cm-1 of the spectrum. Four different cannabin…
Chemometric determination of lipidic parameters in serum using ATR measurements of dry films of solvent extracts
2013
Attenuated total reflectance (ATR) infrared spectroscopy of dried organic extracts of serum samples has been evaluated as a fast method for the determination of triglycerides, cholesterol, high density lipoprotein (HDL) and low density lipoprotein (LDL). After careful selection of solvents based on green parameters, serum samples were extracted using hexane-isopropanol and ethyl acetate-ethanol mixtures. Microscopy studies and comparison with standard spectra were performed in order to investigate whether the proposed methodology is suitable for the quantification of lipids in serum samples. The results of these preliminary studies confirmed that the variations in the IR spectra of sample e…
Capillary electrokinetic fractionation mass spectrometry (CEkF/MS): Technology setup and application to metabolite fractionation from complex samples…
2014
Capillary electrokinetic fractionation (CEkF) is investigated as a new, simple, and robust approach for semipreparative and analytical sample analysis based on pKa -dependant pH-driven electrophoretic mobility. CEkF was optimized with contactless conductivity detection and conducted with 10 kV reverse voltage for 10 min, then coupled on/at-line to ESI/MS. We propose a semi-empirical model with 14 representative compounds based on the correlation between sample/medium pH regulating the partial charge, the electrokinetic loading of the capillary and intensity (I) of analytes. According to the model, an empirical function (I = f (pH)) could be derived to calculate the acid dissociation constan…
Rapid determination of pharmaceuticals in wastewater by direct infusion HRMS using target and suspect screening analysis
2021
Abstract A wide-scope screening of active pharmaceutical ingredients (APIs) and their transformation products (TPs) in wastewater can yield valuable insights and pinpoint emerging contaminants that have not been previously reported. Such information is relevant to investigate their occurrence and fate in various environmental compartments. In this study, we explored the applicability of direct infusion high resolution mass spectrometry (DI-HRMS) for comprehensive and rapid detection of APIs and their TPs in wastewater samples. The method was developed using a Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) system and incorporated both wide-scope suspect screening and…
Evaluation of analytical performance of gas chromatography coupled with atmospheric pressure chemical ionization Fourier transform ion cyclotron reso…
2019
Abstract A new analytical method was established and validated for the analysis of eighteen halogenated flame retardants (HFRs)in food products. Gas chromatography (GC) coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) employing atmospheric pressure chemical ionization (APCI) was used for the identification and quantitation of contaminants. Intra-laboratory validation of the method was performed with respect to recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and trueness was verified where possible by analysis of reference materials (RMs). The validation results indicated recoveries of ana…
New insights in the formation of silanol defects in silicalite-1 by water intrusion under high pressure.
2010
International audience; The "water-silicalite-1" system is known to act as a molecular spring. The successive intrusion-extrusion cycles of liquid water in small crystallites (6 × 3 × 0.5 μm(3)) of hydrophobic silicalite-1 were studied by volumetric and calorimetric techniques. The experiments displayed a decrease of the intrusion pressure between the first intrusion-extrusion cycle and the consecutive ones, whereas the extrusion pressures remained unchanged. However, neither XRD studies nor SEM observations revealed any structural and morphological modifications of silicalite-1 at the long-range order. Such a shift in the value of the intrusion pressure after the first water intrusion-extr…
First signals of electrochemically oxidized species of TTF and TMT-TTF : a study by in situ spectroelectrochemical FTIR and DFT calculations
2003
A first study by in situ FTIR spectroelectrochemistry of TTF and TTM-TTF has been undertaken. The oxidation, in this case, is caused only by electrochemistry, which constitutes a clear advantage over chemical oxidation since no side products are present in the solution. In this context, we obtained the signals of neutral, radical cation, and dication species of TTF and TTM-TTF. The experimental conditions were chosen in order to avoid the possible formation of π-dimer species and to obtain a satisfactory signal-to-noise ratio. A weak signal was detected for TTF and a stronger one for TTM-TTF. The changes induced by the oxidation process in the IR spectra of TTF and TTM-TTF have been analyze…