Search results for "Fractures"
showing 10 items of 379 documents
Clinical performance of a highly portable, scanning calcaneal ultrasonometer.
2001
The aim of this study was to establish a normative database, assess precision, and evaluate the ability to identify women with low bone mass and to discriminate women with fracture from those without for a highly portable, scanning calcaneal ultrasonometer: the QUS-2. Fourteen hundred and one Caucasian women were recruited for the study. Among them were 794 healthy women 25–84 years of age evenly distributed per 10-year period to establish a normative database. Of these, 171 aged 25–34 years were defined as the young normal group for the purpose of T-score determination. Precision was assessed within 1 day (short-term) and over a 16-week period (long-term) in 79 women aged 25–84 years. Five…
Monitoring bone growth using quantitative ultrasound in comparison with DXA and pQCT.
2008
Quantitative ultrasound (QUS) is a safe, inexpensive, and nonradiation method for bone density assessment. QUS correlates with, and predicts fragility fractures comparable to, dual-energy X-ray absorptiometry (DXA)-derived bone mineral density (BMD) in postmenopausal women. However, its validity in monitoring bone growth in children is not well understood. Two hundred and fifty-eight 10-13 yr pubertal girls and 9 37-43 yr adults without diseases or history of medications known to affect bone metabolism were included in the 2-yr prospective study. Calcaneal broadband ultrasound attenuation (cBUA) was assessed using QUS-2 (Quidel, Santa Clara, CA), speed of sound of tibial shaft (tSOS) using …
Estimation of structural and geometrical properties of cortical bone by computerized tomography in 78-year-old women
2009
The structural and geometrical properties of the tibia shaft were investigated at two sections by means of computerized tomography (CT) in 78-year-old women with high (n = 19) and low (n = 17) calcaneal bone mineral density (BMD, g/cm3) previously measured by 125I-photon absorption. The high BMD group had a 20-21% higher tibial BMD and 9-12% higher bone cross-sectional area than was observed in the low BMD group. The distribution of bone mass indicated that the low BMD group had lost bone mainly from the endosteal surface, especially in the anterior part of the tibia. However, both groups had a similar basic pattern of mass distribution at the measured sections. The high BMD group had highe…
Posterior perilunate carpal dislocation associated with a multifragmentary distal radius fracture.
2009
Summary Dorsal perilunate wrist dislocations are rare. Associated carpal bones or radial styloid process fractures can occur and be included in the current classifications. The authors report an unusual association of dorsal perilunate wrist dislocation with a multifragmentary distal radius fracture. Such traumatic entity has never been previously described. Poor functional outcome may justify the inclusion of associated complex forearm bone fractures in wrist dislocation classifications.
A Locked Intraosseous Nail for Transverse Patellar Fractures: A Biomechanical Comparison with Tension Band Wiring Through Cannulated Screws.
2018
Background Displaced transverse patellar fractures require open reduction and internal fixation. State-of-the-art stabilization techniques are tension band wiring (TBW) using Kirschner wires or cannulated screws. These techniques are associated with high rates of secondary fracture displacement, implant migration, implant prominence, wound-healing disturbances, and the need for implant removal. Recently, a locked intraosseous patellar nail prototype was developed. The aim of the present study was to investigate the biomechanical performance of this nail compared with TBW using cannulated screws. Methods Seven paired fresh-frozen human cadaveric knees were stripped of all soft tissues except…
Correlation of Tibial Low-Frequency Ultrasound Velocity with Femoral Radiographic Measurements and BMD in Elderly Women
2009
The ultrasonic axial transmission technique has been proposed as a method for cortical bone characterization. Using a low enough center frequency, Lamb modes can be excited in long bones. Lamb waves propagate throughout the cortical bone layer, which makes them appealing for characterizing bone material and geometrical properties. In the present study, a prototype low-frequency quantitative ultrasonic axial transmission device was used on elderly women (n = 132) to investigate the relationships between upper femur geometry and bone mineral density (BMD) and tibial speed of sound. Ultrasonic velocities (V) were recorded using a two-directional measurement set-up on the midtibia and compared …
Screw‐in‐screw fixation of fragility sacrum fractures provides high stability without loosening—biomechanical evaluation of a new concept
2020
Surgical treatment of fragility sacrum fractures with percutaneous sacroiliac (SI) screw fixation is associated with high failure rates. Turn-out is detected in up to 20% of the patients. The aim of this study was to evaluate a new screw-in-screw implant prototype for fragility sacrum fracture fixation. Twenty-seven artificial hemipelvises were assigned to three groups (n = 9) for instrumentation of an SI screw, the new screw-in-screw implant prototype, ora transsacral screw. Before implantation, a vertical osteotomy was set in zone 1 after Denis. All specimens were biomechanically tested to failure in upright position. Validated setup and test protocol were used for complex axial and torsi…
Impaired geometric properties of tibia in older women with hip fracture history.
2007
This study evaluated side-to-side differences in tibial mineral mass and geometry in women with previous hip fracture sustained on average 3.5 years earlier. Both tibial mineral mass and geometry were found to be reduced in the fractured leg. INTRODUCTION: The purpose of this study was to evaluate side-to-side differences in tibial mineral mass and geometry after hip fracture and to assess the determinants of such differences. METHODS: Thirty-eight 60- to 85-year-old women with a previous hip fracture and 22 same-aged control women without fractures participated in the study. Bone characteristics of the distal tibia and tibial shaft of both legs were assessed using pQCT in order to compare …
Reaction of the bone structure to methotrexate-Palacos flow y. Experimental investigations in animals.
1989
With the combined osteosynthesis of pathological fractures in association with tumors and/or metastases in mind, E. Merck (Darmstadt, FRG) developed a bone cement containing a cytostatic agent, methotrexate-Palacos flow y (MTX-Pf). The animal-experimental study presented here investigates the tolerability of MTX-Pf in the femurs of rabbits with lateral comparison. In these investigations we used both the concentration of 0.63% MTX, as is currently used in standard clinical surgery, as well as a much higher concentration of 2.5% MTX. The histological sections were investigated using microradiographic methods and provided no indication of any significant differences between the femora with th…
Treatment of distal intraarticular tibial fractures: A biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis
2015
In factures of the distal tibia with simple articular extension, the optimal surgical treatment remains debatable. In clinical practice, minimally invasive plate osteosynthesis and intramedullary nailing are both routinely performed. Comparative biomechanical studies of different types of osteosynthesis of intraarticular distal tibial fractures are missing due to the lack of an established model. The goal of this study was first to establish a biomechanical model and second to investigate, which are the biomechanical advantages of angle-stable plate osteosynthesis and intramedullary nailing of distal intraarticular tibial fractures. Seven 4(th) generation biomechanical composite tibiae feat…