Primary Stability of a Hybrid Self-Tapping Implant Compared to a Cylindrical Non-Self-Tapping Implant with Respect to Drilling Protocols in an Ex Viv…

2011

Background: Modifications of implant design have been intending to improve primary stability. However, little is known about investigation of a hybrid self-tapping implant on primary stability. Purposes: The aims of this study were to evaluate the primary stability of two hybrid self-tapping implants compared to one cylindrical non-self-tapping implant, and to elucidate the relevance of drilling protocols on primary stability in an ex vivo model. Materials and Methods: Two types of hybrid self-tapping implants (Straumann® Bone Level implant [BL], Straumann® Tapered Effect implant [TE]) and one type of cylindrical non-self-tapping implant (Straumann® Standard Plus implant [SP]) were investig…

Insertion torqueMaterials sciencebusiness.industrymedicine.medical_treatmentImplant designDentistryResonance frequency analysisDental Stress AnalysismedicineImplantOral SurgeryBone levelDental implantbusinessGeneral DentistryEx vivoClinical Implant Dentistry and Related Research
researchProduct

Assessment of Osstell ISQ's reliability for implant stability measurement: a cross-sectional clinical study

2013

Resonance frequency analysis (RFA) allows assess implant stability by measuring implant oscillation frequency on the bone. RFA is an objective and non-invasive method for implant stability measurement, although scarce evidence has been provided so far on its reliability. Objectives: Assess the Osstell ISQ system's reliability (i.e., its measurement reproducibility and repeatability) by means of the intraclass correlation coefficient (ICC) as statistical method. Study Desing: Implants stability registers were completed by means of Osstell ISQ on 85 implants on 23 patients. Six measurements were completed on each implant by means of two different SmartPegs (types I and II); that is, three con…

Intraclass correlationDentistryOdontologíaVibrationStability (probability)Clinical studyHumansDental Restoration FailureGeneral DentistryReliability (statistics)MathematicsDental ImplantsOrthodonticsReproducibilitybusiness.industryReproducibility of ResultsRepeatability:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludBiomechanical PhenomenaResonance frequency analysisCross-Sectional StudiesOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgeryImplantbusinessImplantology
researchProduct

Analysis of marginal bone loss and implant stability quotient by resonance frequency analysis in different osteointegrated implant systems. Randomize…

2019

Background The aim of the present prospective clinical study is to compare the stability of the implant-bone interface by the ISQ quotient and marginal bone loss (MBL) rate during one year of follow-up in four system implants with the same surface and different design. Material and Methods Prospective randomized clinical trial of 21 patients in which four implant systems with the same surface and different design were placed. Patients were treated by the same operator following a similar surgical protocol with submerged technique. The second surgery to perform the prosthesis was performed at 3 months. All patients went to their review at 6 months and a year. A periapical radiograph for cres…

Malemedicine.medical_treatmentAlveolar Bone LossDentistryDental AbutmentsMandibleProsthesisOsseointegrationlaw.invention03 medical and health sciences0302 clinical medicineRandomized controlled triallawOsseointegrationMaxillaMedicineHumansProspective StudiesGeneral DentistryAgedDental Implantsbusiness.industryResearchDental prosthesisDental Implantation EndosseousResonance Frequency Analysis030206 dentistryMiddle Aged:CIENCIAS MÉDICAS [UNESCO]Implant stability quotientResonance frequency analysisDental Implant-Abutment DesignOtorhinolaryngologyDental Prosthesis DesignUNESCO::CIENCIAS MÉDICASSurgeryFemaleImplantDental Prosthesis Implant-SupportedOral SurgerybusinessMedicina Oral, Patología Oral y Cirugía Bucal
researchProduct

Predictability of the resonance frequency analysis in the survival of dental implants placed in the anterior non-atrophied edentulous mandible.

2010

Background: Dental primary implant stability is considered essential in the success of the osseointegration process. The recent advent of the resonance frequency analysis (RFA) seems to effectively measure primary implant stability, although its relationship with implant survival has to be further established. Patients and Methods: Seventy patients with complete mandibular edentulism underwent dental implant rehabilitation by means of the placement of 68 dental implants within the interforaminal region and subsequent placement of an overdenture. Primary implant stability was measured by means of RFA and it was expressed in terms of imPrimary implant stability was measured by means of RFA an…

Malemedicine.medical_treatmentDentistryOsseointegrationDental Prosthesis RetentionHumansMedicineDental implantGeneral DentistrySurvival rateOrthodonticsEdentulismbusiness.industryDental Implantation EndosseousEdentulous mandibleMiddle AgedImplant stability quotientmedicine.disease:CIENCIAS MÉDICAS [UNESCO]Resonance frequency analysisOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASFemaleSurgeryImplantMouth Edentulousbusiness
researchProduct

Improving Isolation of Blindly Separated Sources Using Time-Frequency Masking

2008

A refinement technique based on time-frequency masking is proposed to improve source isolation in blind audio source separation algorithms. The refinement technique uses an energy-normalized source-to-interference ratio in order to identify and eliminate interfering energy from the extracted sources. Some examples using this refinement method with different separation algorithms are discussed. The results show that source isolation can be significantly enhanced with negligible degradation of the separated sources.

Masking (art)business.industryComputer scienceApplied MathematicsSpeech recognitionPattern recognitioncomputer.software_genreBlind signal separationIndependent component analysisTime–frequency analysisSignal ProcessingSource separationArtificial intelligenceIsolation (database systems)Electrical and Electronic EngineeringAudio signal processingbusinesscomputerEnergy (signal processing)IEEE Signal Processing Letters
researchProduct

Biomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis

2015

Background This study evaluated the influence of implant site preparation depth on primary stability measured by insertion torque and resonance frequency analysis (RFA). Material and Methods Thirty-two implant sites were prepared in eight veal rib blocks. Sixteen sites were prepared using the conventional drilling sequence recommended by the manufacturer to a working depth of 10mm. The remaining 16 sites were prepared using an oversize drilling technique (overpreparation) to a working depth of 12mm. Bone density was determined using cone beam computerized tomography (CBCT). The implants were placed and primary stability was measured by two methods: insertion torque (Ncm), and RFA (implant s…

Materials scienceBone densityResearchDrilling030209 endocrinology & metabolismOdontología030206 dentistryImplant stability quotient:CIENCIAS MÉDICAS [UNESCO]Stability (probability)Ciencias de la salud03 medical and health sciencesResonance frequency analysis0302 clinical medicineUNESCO::CIENCIAS MÉDICASTorqueImplantTomographyGeneral DentistryImplantologyBiomedical engineering
researchProduct

Repeatability of the resonance frequency analysis values in implants with a new technology

2019

Background Assess the reliability (by means of reproducibility and repeatability) of the PenguinRFA system, analyse the ISQ values of different implant types and correlate the ISQ with the insertion torque during the placement of the implant. Material and Methods 120 rough surface implants were placed in bovine bone (type II and III). The implants were divided into groups, according to its design. Once the implants were in place, the exact insertion torque was registered. Then, primary stability was measured by means of the resonance frequency analysis with the PenguinRFA and the Osstell ISQ devices. In each implant two transducers of each device were used. Three measurements were obtained …

Materials scienceIntraclass correlationVibrationDental Prosthesis Retention03 medical and health sciences0302 clinical medicineAnimalsGeneral DentistryDental ImplantsReproducibilityResearchDental Implantation EndosseousResonance Frequency AnalysisReproducibility of Results030206 dentistryRepeatability:CIENCIAS MÉDICAS [UNESCO]Implant stability quotientResonance frequency analysisDental Prosthesis DesignTorqueOtorhinolaryngologyRough surfaceUNESCO::CIENCIAS MÉDICASImplant typesCattleSurgeryImplantOral SurgeryBiomedical engineeringMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

The effects of surgical preparation techniques and implant macro-geometry on primary stability : an in vitro study

2016

Background The attainment of a good primary stability is a necessary condition to ensure the success of osseointegration in implantology. In type IV cancellous bone, however, it is possible that a reduced primary stability can lead to an increased rate of failure. The aim of this study was therefore to determine, with the help of the resonance frequency (Osstell mentor), which technique of implant site preparation (piezo surgery, conventional, under-preparation, bone compaction, osteodistraction) and macro-geometry is able to improve implant stability in type IV cancellous bone. Material and Methods 10 pig ribs were prepared with a surgical pre-drilled guide, calibrated for a correct implan…

Materials scienceSwineResonance frequency analysisDentistryIn Vitro TechniquesOsseointegration03 medical and health sciences0302 clinical medicineimplant primary stability; implant site preparation; resonance frequency analysis; surgery; otorhinolaryngology2734 pathology and forensic medicine; dentistry (all)OsseointegrationPreoperative CaremedicineAnimalsIn vitro studySurgical preparationImplant primary stability030223 otorhinolaryngologyGeneral DentistryImplant site preparationRib cagebusiness.industryResearch030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Implant stability quotientImplant primary stability; Implant site preparation; Resonance frequency analysis; Animals; Dental Implantation; In Vitro Techniques; Preoperative Care; Swine; OsseointegrationDental Implantationmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryImplantOral SurgerybusinessCancellous bone
researchProduct

A Linear Cost Algorithm to Compute the Discrete Gabor Transform

2010

In this paper, we propose an alternative efficient method to calculate the Gabor coefficients of a signal given a synthesis window with a support of size much lesser than the length of the signal. The algorithm uses the canonical dual of the window (which does not need to be calculated beforehand) and achieves a computational cost that is linear with the signal length in both analysis and synthesis. This is done by exploiting the block structure of the matrices and using an ad hoc Cholesky decomposition of the Gabor frame matrix.

Matrix (mathematics)Signal ProcessingGabor waveletShort-time Fourier transformGabor transformElectrical and Electronic EngineeringAlgorithmSparse matrixMathematicsMatrix decompositionCholesky decompositionTime–frequency analysisIEEE Transactions on Signal Processing
researchProduct

Salikteņu lietojums korporatīvās atbildības ziņojumos

2018

Šī pētījuma mērķis ir noskaidrot, kāda salikteņu forma un funkcija ir visbiežāk izmantota korporatīvās atbildības ziņojumos. Analīzei tika izvēlēti trīs korporatīvās atbildības ziņojumi banku nozarē. Izmantotā empīriskā pētījuma metode bija biežuma analīze, un analīze tika balstīta uz Bauera (1983), Levija (1998) un Liebera (2009) teorijām. Pētījuma rezultāti liecina, ka katram analizētajam korporatīvās atbildības ziņojumam ir sava visbiežāk lietotā salikteņu forma. Visvairāk lietotais saliktenis visos analizētajos korporatīvās atbildības ziņojumos ir salikts lietvārds, un vismazāk lietoti ir saliktie darbības vārdi un apstākļa vārdi. Analīze arī parāda, ka lielākā salikteņu daļa ir saistīt…

MorphologyValodniecībaCompoundsFrequency analysisFunctionForm
researchProduct