Search results for "Full width at half maximum"
showing 9 items of 89 documents
A large-area scintillating fibre detector for relativistic heavy ions
1998
Abstract A scintillating fibre detector for relativistic heavy ions with an active area of 50 × 50 cm 2 has been developed and was tested with various ion beams (1 ≤ Z ≤ 92). At count rates of up to 10 5 particles/s, the position resolution was found to be determined by the fibre width of 1 mm; depending on the nuclear charge of the beam, efficiencies between 89% and 100% and time resolutions between 800 and 200 ps (FWHM) were obtained.
The Evolution of Disk Winds from a Combined Study of Optical and Infrared Forbidden Lines
2020
We analyze high-resolution (dv=<10km/s) optical and infrared spectra covering the [OI] 6300 angstrom and [NeII] 12.81 micron lines from a sample of 31 disks in different evolutionary stages. Following work at optical wavelengths, we use Gaussian profiles to fit the [NeII] lines and classify them into HVC (LVC) if the line centroid is more (less) blueshifted than 30 km/s with respect to the stellar radial velocity. Unlike for the [OI] where a HVC is often accompanied by a LVC, all 17 sources with a [NeII] detection have either a HVC or a LVC. [NeII] HVCs are preferentially detected toward high accretors (Macc > 10$^{-8}$ Msun/yr) while LVCs are found in sources with low Macc, low [OI] …
Vibrational properties of the surface-nonbridging oxygen in silica nanoparticles
2008
By studying the site-selective luminescence spectra of oxidized silica nanoparticles we identify the electronic and the vibrational lines associated with the surface nonbridging oxygen, $\ensuremath{\equiv}{\text{Si-O}}^{\ifmmode\bullet\else\textbullet\fi{}}$. This defect emits a zero-phonon line inhomogeneously distributed around 2.0 eV with full width at half maximum of 0.04 eV, weakly coupled with the local ${\text{Si-O}}^{\ifmmode\bullet\else\textbullet\fi{}}$ stretching mode whose frequency is measured to be $920\text{ }{\text{cm}}^{\ensuremath{-}1}$. These findings are different from those of the well-characterized defect in the bulk silica thus evidencing structural peculiarities of …
High-resolution spectroscopy of the ν3 band of WF6 and ReF6 in a supersonic jet
2002
We have recorded the Fourier-transform infrared (FTIR) spectrum of the ν3 fundamental band of WF6 in a continuous supersonic jet expansion with an instrumental bandwidth of 0.0024 cm−1 (FWHM, full width at half maximum, unapodized), using a Bomem DA.002 spectrometer. Some parts of this band have also been recorded with 0.0007 cm−1 bandwidth using a diode laser spectrometer combined with a pulsed slit jet expansion. A multiple-pass arrangement has been used for the slit jet to observe low-intensity lines. In each case, we have used a WF6:He mixture with a seeding ratio 1:3 leading to a rotational temperature of ca. 50 K. This work extends the previous investigation of Takami and Kuze [J. Che…
Development of Slewing Mirror Telescope Optical System for the UFFO-pathfinder
2013
The Slewing Mirror Telescope (SMT) is the UV/optical telescope of UFFO-pathfinder. The SMT optical system is a Ritchey-Chretien (RC) telescope of 100 mm diameter pointed by means of a gimbal-mounted flat mirror in front of the telescope. The RC telescope has a 17 × 17arcmin2 in Field of View and 4.3 arcsec resolution (full width half maximum of the point spread function) The beam-steering mirror enables the SMT to access a 35 × 35degree region and point and settle within 1 sec. All mirrors were fabricated to about 0.02 wavelengths RMS in wave front error (WFE) and 84.7% average reflectivity over 200 nm ~ 650 nm. The RC telescope was aligned to 0.05 wavelengths RMS in WFE (test wavelength 63…
Direct Measurement of Mammographic X-Ray Spectra with a Digital CdTe Detection System
2012
In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate X-ray spectroscopy in mammography (1–30 keV). The DPP system performs a height and shape analysis of the detector pulses, sampled and digitized by a 14-bit, 100 MHz ADC. We show the results of the characterization of the detection system both at low and high photon counting rates by using monoenergetic X-ray sources and a nonclinical X-ray tube. The detection system exhibits excellent performance up to 830 kcps with an energy resolution of 4.5% FWHM at 22.1 keV. Direct measurements of clinical molybdenum X-ray spectra were carried out by using a pinhole…
All polarization-maintaining assively mode-locked yb-doped fiber laser : pulse compression using an anomalous polarization-maintaining photonic cryst…
2019
We report the generation of short pulses at 1 μm using an all-polarization-maintaining (PM) fiber configuration. The pulses are provided by an all normal-dispersion Fabry-Perot Yb-doped cavity and are compressed with an anomalous polarization-maintaining photonic crystal fiber (PM PCF). Opposed to standard configurations; here the filtering action is solely performed by the finite bandwidth of the gain medium. The laser generates 8 ps width sech 2 profile pulses at 1046.8 nm with a −10 dB bandwidth of 5.9 nm. After compression using the PM PCF, pulses with an FWHM of 3 ps were obtained, limited by the actual value of the available anomalous dispersion. We also report the changes in the outp…
High Bias Voltage CZT Detectors for High-flux Measurements
2017
In this work, we present the performance of new travelling heater method (THM) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Thick planar detectors (3 mm thick) with gold electroless contacts on CZT crystals grown by Redlen Technologies (Victoria BC, Canada) were realized, with a planar cathode covering the detector surface (4.1 x 4.1 mm(2)) and a central anode (2 x 2 mm(2)) surrounded by a guard ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA/cm(2) at 1000 V/cm), allow good room temperature operation even at high bias voltages (> 7000 V/cm). At low rates, the detectors exhibit an energy resolution around 4 % FWIEM at 59.5…
Microscale X-ray mapping of CZT arrays: Spatial dependence of amplitude, shape and multiplicity of detector pulses
2018
In this work, we present the results of a microscale X-ray mapping of a 2 mm thick CZT pixel detector, with pixel pitches of 500 μm and 250 μm, using collimated synchrotron X-ray sources at the Diamond Light source (U. K.). The detector is dc coupled to a fast and low noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to perform online fast pulse shape and height analysis (PSHA), with low dead time and reasonable energy resolution at both low and high fluxes. The detector allows high bias voltage operation (> 5000 V/cm) and good energy resolution at room temperature (5.3 %, 2.3 % and 2.1 % FWHM at 22.1, 59…