Search results for "Full width"

showing 10 items of 91 documents

Improving the Performance of Quasi-Hemispherical CdZnTe Detectors Using Infrared Stimulation

2012

The influence of monochromatic optical stimulation with wavelengths from 400 to 1100 nm on the characteristics of CdZnTe quasi-hemispherical detectors was studied. It was found that illumination with infrared (IR) light with wavelengths of 870-900 nm close to the absorption edge of the CdZnTe significantly improves the performance of the detector at room temperature. Improvement can be achieved with low-intensity IR illumination at 1-300 μW depending on the chosen wavelength of illumination. Higher intensity illumination was observed to lead to the degradation of the detector's spectrometric characteristics. IR radiation was noted to influence the detector's sensitivity, changing the equili…

PhysicsNuclear and High Energy PhysicsInfraredbusiness.industryDetectorWide-bandgap semiconductorlaw.inventionWavelengthFull width at half maximumOpticsNuclear Energy and EngineeringAbsorption edgelawOptoelectronicsElectrical and Electronic EngineeringbusinessDiodeLight-emitting diodeIEEE Transactions on Nuclear Science
researchProduct

A broad iron line in the Chandra/HETG spectrum of 4U 1705-44

2004

We present preliminary results from a Chandra 30 ks observation of the atoll sourco 4U 1705 44. In particular we concentrate on the study of the iron Kα line, using the HEG spectrometer. The iron Kα line at ~ 6.6 keV is found to be intrinsically broad (FWHM ~ 1.7 keV); its width can be explained by reflection from a cold accretion disk extending down to ~ 17 km from the neutron star center or by Compton broadening in the hotter (~ 3 – 4 keV) corona.

PhysicsNuclear and High Energy PhysicsNeutron starFull width at half maximumSpectrometerAccretion discK-alphaAstronomyAstrophysicsAtomic and Molecular Physics and Optics
researchProduct

In-beam tests of scintillating fibre detectors at MAMI and at GSI

2008

The performance of scintillating fibre detectors was studied with electrons at the spectrometer facility of the Mainz microtron MAMI, as well as in a C-12 beam of 2 AGeV energy and in a beam of different particle species at GSI. Multi-anode photomultipliers were used to read out one or more bundles of 128 fibres each in different geometries. For electrons a time resolution of FWHM = 1 ns was measured in a single detector plane with a detection efficiency epsilon > 99%. A time resolution of 310 ps (FWHM) between two planes of fibres was achieved for carbon ions, leading to a FWHM = 220 ps for a single detector. The hit position residual was measured with a width of FWHM = 0.27 mm. The var…

PhysicsNuclear and High Energy PhysicsPhotomultiplierSpectrometerbusiness.industryDetectorFOS: Physical sciencesCharged particleParticle detectorNuclear physicsFull width at half maximumOpticsNuclear Experiment (nucl-ex)businessInstrumentationMicrotronNuclear ExperimentBeam (structure)
researchProduct

A time-differential Mössbauer emission spectrometer with high efficiency and high time resolution

1986

A high-efficiency, high rate-capability, computer-based measuring setup for Time-Differential Mossbauer Spectroscopy was constructed. Applying NaI(Tl) and plastic scintillators for the detection of the 14.4 keV and 122 keV γ-radiation respectively, a superior timing (2, 3 ns FWHM) was achieved by a “fast-fast-ultra fast” timing method developed for that purpose.

PhysicsNuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsAnalytical chemistryTime resolutionScintillatorCondensed Matter PhysicsAtomic and Molecular Physics and OpticsFull width at half maximumMössbauer spectroscopyPhysical and Theoretical ChemistryThin filmSpectroscopyDifferential (mathematics)Emission SpectrometerHyperfine Interactions
researchProduct

Digital performance improvements of a CdTe pixel detector for high flux energy-resolved X-ray imaging

2015

Abstract Photon counting detectors with energy resolving capabilities are desired for high flux X-ray imaging. In this work, we present the performance of a pixelated Schottky Al/p-CdTe/Pt detector (4×4) coupled to a custom-designed digital readout electronics for high flux measurements. The detector (4×4×2 mm 3 ) has an anode layout based on an array of 16 pixels with a geometric pitch of 1 mm (pixel size of 0.6 mm). The 4-channel readout electronics is able to continuously digitize and process the signals from each pixel, performing multi-parameter analysis (event arrival time, pulse shape, pulse height, pulse time width, etc.) even at high fluxes and at different throughput and energy re…

PhysicsNuclear and High Energy PhysicsPixelPhysics::Instrumentation and Detectorsbusiness.industryEnergy-resolved photon counting detectorSettore FIS/01 - Fisica SperimentaleDetectorSchottky diodePixel detectorSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Photon countingCharge sharingCdTe detectorHigh photon counting rateFull width at half maximumOpticsDigital pulse processingMonochromatic colorbusinessInstrumentationPulse shape analysiEnergy (signal processing)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Timing results using an FPGA-based TDC with large arrays of 144 SiPMs

2015

Silicon photomultipliers (SiPMs) have become an alternative to traditional tubes due to several features. However, their implementation to form large arrays is still a challenge especially due to their relatively high intrinsic noise, depending on the chosen readout. In this contribution, two modules composed of SiPMs with an area of roughly mm mm are used in coincidence. Coincidence resolving time (CRT) results with a field-programmable gate array, in combination with a time to digital converter, are shown as a function of both the sensor bias voltage and the digitizer threshold. The dependence of the CRT on the sensor matrix temperature, the amount of SiPM active area and the crystal type…

PhysicsNuclear and High Energy PhysicsPixelbusiness.industryDetectorBiasingNoise (electronics)Time-to-digital converterFull width at half maximumSilicon radiation detectorsSilicon photomultiplierOpticsNuclear Energy and EngineeringGate arrayPositron emission tomography (PET)Nuclear medicineTEORIA DE LA SEÑAL Y COMUNICACIONESElectronic engineeringTrigger circuitsElectrical and Electronic Engineeringbusiness
researchProduct

Effects of scintillation light collection on the time resolution of a time-of-flight detector for annihilation quanta

1990

Monte Carlo methods were used to simulate the production and collection of scintillation light in a BaF/sub 2/ crystal. The calculated results were compared to measured values for detectors with different heights. Based on this simulation, a TOF (time-of-flight) detector consisting of two conical BaF/sub 2/ crystals (base radius 18 mm, top radius 15 mm, height 25 mm) was assembled. The total time resolution of this system was (210+or-5) ps FWHM (full width at half maximum) for 511-keV annihilation quanta and was found to be independent of the source position between the detectors. Since the time resolution of the TOF detector system consisting of two conical BaF/sub 2/ crystals is sufficien…

PhysicsNuclear and High Energy PhysicsScintillationAnnihilationTime of flight detectorPhysics::Instrumentation and Detectorsbusiness.industryDetectorMonte Carlo methodRadiusNuclear physicsFull width at half maximumOpticsNuclear Energy and EngineeringScintillation counterElectrical and Electronic EngineeringbusinessIEEE Transactions on Nuclear Science
researchProduct

Spectroscopic response of a CdZnTe multiple electrode detector

2007

Abstract The spectroscopic performances of a CdZnTe detector (crystal size: 5×5×0.9 mm 3 ) with five electrodes (cathode, anode and three steering electrodes) were studied. The anode layout, which consists of a circular electrode ( φ =80 μm) surrounded by two ring electrodes (gap=100 μm; radial width Δ r =100 μm) and by one electrode that extends to the edge of the crystal, is mostly sensitive to the electron carriers, overcoming the well known effect of the hole trapping in the measured spectra. We report on the spectroscopic response of the detector at different bias voltages of the electrodes and at various photon energies ( 109 Cd, 241 Am and 57 Co sources). The CdZnTe detector exhibits…

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryCdZnTe detectorSteering electrodeDetectorMultiple electrode detectorElectronSmall pixel effectCathodeAnodelaw.inventionCrystalFull width at half maximumX-ray and gamma ray spectroscopylawElectrodeOptoelectronicsbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Experimental results from Al/p-CdTe/Pt X-ray detectors

2013

Abstract Recently, Al/CdTe/Pt detectors have been proposed for the development of high resolution X-ray spectrometers. Due to the low leakage currents, these detectors allow high electric fields and the pixellization of anodes with the possibility to realize single charge carrier sensing detectors. In this work, we report on the results of electrical and spectroscopic investigations on CdTe diode detectors with Al/CdTe/Pt electrode configuration (4.1×4.1×0.75 and 4.1×4.1×2 mm 3 ). The detectors are characterized by very low leakage currents in the reverse bias operation: 0.3 nA at 25 °C and 2.4 pA at −25 °C under a bias voltage of −1000 V. The spectroscopic performance of the detectors at b…

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryDetectorX-ray detectorBiasingPhoton countingFull width at half maximumElectric fieldOptoelectronicsCharge carrierbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Longitudinal and transverse momentum distributions of 9Li fragments from break-up of 11Li

1995

7 pages, 3 figures, 1 table.

PhysicsNuclear and High Energy PhysicsTransverse planeFull width at half maximumMomentum (technical analysis)Break-UpSignificant differenceTransverse momentumSigmaHaloAtomic physicsNuclear Physics
researchProduct