Search results for "Fundamental frequency"

showing 8 items of 28 documents

Characterization and Error Compensation of a Rogowski Coil in the Presence of Harmonics

2011

This paper reports the results of an experimental study dealing with a commercial Rogowski coil current transducer (RCCT) in the presence of harmonic distortion. The RCCT was observed under two conditions: 1) sinusoidal excitation with frequencies from 50 to 750 Hz and 2) nonsinusoidal excitation using fundamental frequency and one harmonic, with adjustable amplitude and phase shift. The experimental results show only a weak dependence of the harmonic current ratio error and phase displacement on the amplitude and phase shift of the excitation harmonic. The phase displacement is also independent of the conductor position within the Rogowski coil window. An error compensation method, based o…

PhysicsTotal harmonic distortionFrequency responsebusiness.industryAcousticsElectrical engineeringFundamental frequencycurrent transducerRogowski coilCurrent measurement current transducer frequency response harmonic distortion power system harmonics Rogowski coil.harmonic distortionHarmonic analysisAmplitudeHarmonicsHarmonicpower system harmonicElectrical and Electronic EngineeringbusinessInstrumentationSettore ING-INF/07 - Misure Elettriche E ElettronicheRogowski coil
researchProduct

Harmonic reduction in CHB 13-level inverters by PAM fundamental-frequency strategy

2019

In this paper cascaded H-bridges (CHB) 13-level inverters are considered and a particular pulse amplitude modulation (PAM) strategy is introduced to mitigate or eliminate many harmonic components on the output voltage, in order to obtain low Total Harmonic Distortion (THD) factor. This procedure defines different dc voltage sources and sets of six switching angles, depending on an integer parameter $q$ belonging to the close interval $I=[11, 15]$ . The obtained THD doesn't depend on modulation index $m$ . The control of $m$ is made by changing the dc voltage sources that depend linearly on m, while the switching angles remain constant. An investigation about the role of the $q$ parameter on…

PhysicsTotal harmonic distortionTotal Harmonic Distortion (THD)Pulse Amplitude Modulation (PAM)Modulation indexGrid CodesFundamental frequencySettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciTopologySettore ING-INF/01 - ElettronicaPulse Amplitude Modulation (PAM); Selective Harmonic Mitigation (SHM); Selective Harmonic Elimination (SHE); Total Harmonic Distortion (THD); Grid CodesSettore ING-IND/31 - ElettrotecnicaSelective Harmonic Mitigation (SHM)Pulse-amplitude modulationGrid CodeHarmonicsHarmonicInverterVoltageSelective Harmonic Elimination (SHE)
researchProduct

Caractérisation des tôles Fer-Silicium en régime dynamique pulsant

1992

Using a characterization method based on the Epstein's frame principle, we study the evolution of the magnetic and losses characteristics of NO Fe-Si sheets with respect to the fundamental frequency, the temperature and the wave front under time-variable sinusoidal or constant wave front trapezoidal magnetic flux density. At last, we modelise the evolution of the iron losses with respect to these parameters, except the temperature

WavefrontChemistryFront (oceanography)General Physics and AstronomyMineralogyFundamental frequency01 natural sciences010305 fluids & plasmasComputational physicsCharacterization (materials science)Magnetic field[PHYS.HIST]Physics [physics]/Physics archives0103 physical sciencesConstant (mathematics)
researchProduct

Exact 3D solution for static and damped harmonic response of simply supported general laminates

2014

International audience; The state-space method is adapted to obtain three dimensional exact solutions for the static and damped dynamic behaviors of simply supported general laminates. The state-space method is written in a general form that permits to handle both cross-ply and antisymmetric angle-ply laminates. This general form also permits to obtain exact solutions for general laminates, albeit with some constraints. For the general case and for the static behavior, either an additive term is added to the load to simulate simply supported boundary conditions, or the plate bends in a particular way. For the dynamic behavior, the general case leads to pairs of natural frequencies for each …

Work (thermodynamics)DampedFOS: Physical sciences[ SPI.MECA.STRU ] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanics of the structures [physics.class-ph]Physics - Classical Physics[ PHYS.MECA.STRU ] Physics [physics]/Mechanics [physics]/Mechanics of the structures [physics.class-ph]Normal modeBoundary value problemLaminateStaticCivil and Structural EngineeringMathematicsState-space methodAntisymmetric relationbusiness.industryIsotropyMathematical analysisClassical Physics (physics.class-ph)HarmonicFundamental frequencyStructural engineeringFinite element methodCeramics and CompositesHarmonicbusinessExact 3D solution
researchProduct

Associations Between Neonatal Cry Acoustics and Visual Attention During the First Year

2020

It has been suggested that early cry parameters are connected to later cognitive abilities. The present study is the first to investigate whether the acoustic features of infant cry are associated with cognitive development already during the first year, as measured by oculomotor orienting and attention disengagement. Cry sounds for acoustic analyses (fundamental frequency; F0) were recorded in two neonatal cohorts at the age of 0–8 days (Tampere, Finland) or at 6 weeks (Cape Town, South Africa). Eye tracking was used to measure oculomotor orienting to peripheral visual stimuli and attention disengagement from central stimuli at 8 months (Tampere) or at 6 months (Cape Town) of age. Only a m…

endocrine systemlcsh:Psychologygenetic structurescrylcsh:BF1-990fundamental frequencyinfanteye trackingattentionFrontiers in Psychology
researchProduct

Associations between neonatal cry acoustics and visual attention during the first year

2019

It has been suggested that early cry parameters are connected to later cognitive abilities. The present study is the first to investigate whether the acoustic features of infant cry are associated with cognitive development already during the first year, as measured by oculomotor orienting and attention disengagement. Cry sounds for acoustic analyses (fundamental frequency; F0) were recorded in two neonatal cohorts at the age of 0–8 days (Tampere, Finland) or at 6 weeks (Cape Town, South Africa). Eye tracking was used to measure oculomotor orienting to peripheral visual stimuli and attention disengagement from central stimuli at 8 months (Tampere) or at 6 months (Cape Town) of age. Only a m…

endocrine systemmedicine.medical_specialtyVisual perceptiongenetic structures515 PsychologyvauvatStimulus (physiology)Audiologyeye tracking03 medical and health sciences0302 clinical medicine3123 Gynaecology and paediatricsCognitive developmentmedicinePsychology0501 psychology and cognitive sciencesfundamental frequencyvastasyntyneetDisengagement theorytarkkaavaisuusGeneral PsychologyOriginal Researchcry05 social sciencesCognitioninfantGazeattentionCohortkatseenseurantaEye trackingkognitiivinen kehitysPsychology030217 neurology & neurosurgeryitkeminen050104 developmental & child psychology
researchProduct

Neural generators of the frequency-following response elicited to stimuli of low and high frequency: A magnetoencephalographic (MEG) study.

2021

The frequency-following response (FFR) to periodic complex sounds has gained recent interest in auditory cognitive neuroscience as it captures with great fidelity the tracking accuracy of the periodic sound features in the ascending auditory system. Seminal studies suggested the FFR as a correlate of subcortical sound encoding, yet recent studies aiming to locate its sources challenged this assumption, demonstrating that FFR receives some contribution from the auditory cortex. Based on frequency-specific phase-locking capabilities along the auditory hierarchy, we hypothesized that FFRs to higher frequencies would receive less cortical contribution than those to lower frequencies, hence supp…

magnetoencephalographyInferior colliculusMaleAuditory Pathwaysauditory plasticityFrequency following responses0302 clinical medicineMEGmedicine.diagnostic_test05 social sciencesAuditory plasticityMagnetoencephalographyElectroencephalographyMedial geniculate bodyspeech sound encodingkuulofrequency following responseshavaintopsykologiamedicine.anatomical_structureNeurologyNeural sourcesAuditory PerceptionEvoked Potentials AuditoryFemalePsychologyärsykkeetRC321-571AdultCognitive NeuroscienceThalamusNeurosciences. Biological psychiatry. NeuropsychiatryCognitive neuroscienceAuditory cortexneural sources050105 experimental psychology03 medical and health sciencesYoung AdultmedicineAuditory systemHumans0501 psychology and cognitive sciencesfundamental frequencyFundamental frequencyAuditory CortextaajuusMagnetoencephalographyFrequency following responseSpeech sound encodingAcoustic Stimulationkognitiivinen neurotiedeNeuroscience030217 neurology & neurosurgeryNeuroImage
researchProduct

Practical Strategies for Stable Operation of HFF-QCM in Continuous Air Flow

2013

Currently there are a few fields of application using quartz crystal microbalances (QCM). Because of environmental conditions and insufficient resolution of the microbalance, chemical sensing of volatile organic compounds in an open system was as yet not possible. In this study we present strategies on how to use 195 MHz fundamental quartz resonators for a mobile sensor platform to detect airborne analytes. Commonly the use of devices with a resonant frequency of about 10 MHz is standard. By increasing the frequency to 195 MHz the frequency shift increases by a factor of almost 400. Unfortunately, such kinds of quartz crystals tend to exhibit some challenges to obtain a reasonable signal-to…

quartz crystal microbalance; high fundamental frequency; allan deviation; turbulences; laminar flow element; acceleration sensitivity; temperature gradientSensors; Volume 13; Issue 9; Pages: 12012-12029
researchProduct