Search results for "GEOM"
showing 10 items of 6506 documents
Effect of lumbar disc replacement on the height of the disc space and the geometry of the facet joints: a cadaver study.
2010
In a study on ten fresh human cadavers we examined the change in the height of the intervertebral disc space, the angle of lordosis and the geometry of the facet joints after insertion of intervertebral total disc replacements. SB III Charité prostheses were inserted at L3-4, L4-5, and L5-S1. The changes studied were measured using computer navigation sofware applied to CT scans before and after instrumentation. After disc replacement the mean lumbar disc height was doubled (p < 0.001). The mean angle of lordosis and the facet joint space increased by a statistically significant extent (p < 0.005 and p = 0.006, respectively). By contrast, the mean facet joint overlap was significantl…
Redesign of a Reverse Shoulder Prosthesis: Kinematic and Mechanical Study
2014
In this work a commercial reverse shoulder prosthesis has been redesigned to improve performances in terms of range of movements of the implant and stability to dislocation. A kinematic and mechanic study has been performed using a realistic solid model of the prothesised shoulder: in particular, all the components of the prosthesis have been acquired via a 3D laser scanner and inserted in a virtual humerus-glenoid system by reproducing the common surgical procedure. The final model has been used to measure the maximum angles of abduction and rotation of the arm and the shear forces that cause dislocation. Modifications proposed to the commercial prosthesis are: a different orientation of t…
Biomechanical testing of different posterior fusion devices on lumbar spinal range of motion.
2019
Abstract Background Recent minimal-invasive posterior fusion devices are supposed to provide stability and obtain fusion in combination with interbody cages in the instrumented segment. The aim of the present study is to evaluate the primary stability of two minimal-invasive posterior prototypes compared to an established spinous process plate and standard pedicle screw instrumentation. Methods Seven fresh frozen human cadaver lumbar spines (L2–L5) were tested in a spinal testing device with a moment of 7.5 Nm. Spinal stability was determined as mean range of motion (RoM) in the segment L3/L4 during extension-flexion, lateral bending and axial rotation. The RoM was measured during five cond…
Stellenwert der MR-Tomographie bei traumatischen Patellaluxationen
1995
PURPOSE To describe the MR imaging findings in patients with lateral patellar dislocation. MATERIAL AND METHODS The MRIs of 31 patients with patellar dislocation were evaluated retrospectively. Arthroscopic surgery was performed in 23 cases. RESULTS Hemarthrosis was found in 30/31, contusions of the lateral femoral condyle in 30/31 and of the medial patellar facet in 26/31 cases. Injury of the medial patellar retinaculum was seen in 28/31 cases. Osteochondral fractures were found in 18 patients; compared to arthroscopy there were one false-positive and 5 false-negative findings concerning loose cartilage bodies. In 7 cases, patellar dislocation was not suspected before MR imaging. CONCLUSIO…
Case series of fluoroscopic findings and 3D reconstruction of human spinal MRIs of the space of Okada.
2020
Objective To better understand the unexpected spread of contrast medium observed by conventional fluoroscopic X-ray images during standard neuraxial techniques used in the treatment of pain. The support of 3D reconstruction of MRI images of structures within the lumbar spine was used to better understand the space of Okada. Methods Lumbar facet joint and epidural corticosteroid injections in five patients under fluoroscopic guidance with loss of resistance to air or saline to identify the facet joints or epidural space. Next, in a retrospective study, the authors examined the retrodural space of Okada and the neighboring tissues with 3D reconstruction of spinal MRIs of seven patients withou…
Comparison of frictional resistance between passive self-ligating brackets and slide-type low-friction ligature brackets during the alignment and lev…
2019
Background To compare the frictional resistance between passive self-ligating brackets and conventional brackets with low-friction ligature under bracket/archwire and root/bone interface during dental alignment and leveling. Material and methods A tridimensional model of the maxilla and teeth of a patient treated with conventional brackets, and slide ligatures was generated employing the SolidWorks modeling software. SmartClip self-ligating brackets and Logic Line conventional brackets were assembled with slide low-friction ligatures, utilizing archwires with different diameters and alloys used for the alignment and leveling stage. Friction caused during the bracket/archwire interface and s…
A reanalysis of spinal motion during vibration
1987
Calibrated film of the motion of the lumbar spine during vibration was reanalysed, making use of a number of computer based techniques to improve accuracy and reduce measurement noise. The results demonstrated resonant behaviour at about 4 Hz and indicated that at vibration levels of the order of 1 m/s2 there exists bending of the order of 1° (peak to peak) between adjacent vertebrae in the lumbar spine. The bending is complex and involves phase differences along the spine and possibly a rocking motion of the pelvis.
Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: …
2020
The aim of this study was to construct a novel, repeatable, reproducible, and accurate measurement protocol for the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere fixed multibracket appliances. A total of 30 brackets were cemented and removed with over 30 extracted teeth embedded into three experimental models of epoxy resin. The models were scanned before and after bracket placement, bracket debonding, and polishing the remaining cement. The brackets were submitted to micro-computed tomogra…
Impaired geometric properties of tibia in older women with hip fracture history.
2007
This study evaluated side-to-side differences in tibial mineral mass and geometry in women with previous hip fracture sustained on average 3.5 years earlier. Both tibial mineral mass and geometry were found to be reduced in the fractured leg. INTRODUCTION: The purpose of this study was to evaluate side-to-side differences in tibial mineral mass and geometry after hip fracture and to assess the determinants of such differences. METHODS: Thirty-eight 60- to 85-year-old women with a previous hip fracture and 22 same-aged control women without fractures participated in the study. Bone characteristics of the distal tibia and tibial shaft of both legs were assessed using pQCT in order to compare …
Morphomechanics of the humero-ulnar joint: I. Joint space width and contact areas as a function of load and flexion angle
1995
BACKGROUND Previous studies have shown that the trochlear notch is deeper than necessary for an exact fit with the humerus. However, humero-ulnar joint space width and contact areas have so far not been quantified for variations in the load and angle of flexion. METHODS Six fresh cadaveric specimens were investigated at 30 degrees, 60 degrees, 90 degrees, and 120 degrees of flexion and at loads of 25 and 500 N, simulating resisted elbow extension. The joint space width and contact were determined, using polyether casting material. RESULTS At 25 N all joints made contact in the ventral and dorsal aspects of the articular surfaces, whereas in the depth of the trochlear notch the joint space w…