Search results for "Gadobutrol"

showing 5 items of 5 documents

A multicenter, site-independent, blinded study to compare the diagnostic accuracy of contrast-enhanced magnetic resonance angiography using 1.0M gado…

2007

Abstract Purpose Prospective evaluation of diagnostic accuracy of single field-of-view contrast-enhanced MR Angiography (ceMRA) with 1.0 M gadobutrol compared to intraarterial DSA in body arteries. Materials and methods In an European multicenter study 179 patients underwent ceMRA and DSA. For each indication five prospectively defined vessel segments were evaluated by local investigators onsite and by three site-independent blinded readers (BR) independently. Results The agreement between ceMRA and DSA diagnosis was statistically significant in the onsite (96.6%) and blinded reader (86.6–90.2%) evaluation. Sensitivity, specificity, accuracy, positive (PPV) and negative predictive values (N…

AdultMalemedicine.medical_specialtyContrast MediaDiagnostic accuracyGadoliniumConstriction PathologicSensitivity and SpecificityMagnetic resonance angiographyGadobutrolmedicineOrganometallic CompoundsHumansRadiology Nuclear Medicine and imagingSingle-Blind MethodProspective StudiesProspective cohort studyAgedAged 80 and overmedicine.diagnostic_testbusiness.industryAngiography Digital SubtractionGeneral MedicineDigital subtraction angiographyArteriesMiddle Agedmedicine.diseasebody regionsStenosismedicine.anatomical_structureAngiographyRadiologyNuclear medicinebusinessMagnetic Resonance Angiographymedicine.drugArteryEuropean journal of radiology
researchProduct

Highly Loaded Semipermeable Nanocapsules for Magnetic Resonance Imaging.

2017

Magnetic resonance imaging has become an essential tool in medicine for the investigation of physiological processes. The key issues related to contrast agents, i.e., substances that are injected in the body for imaging, are the efficient enhancement of contrast, their low toxicity, and their defined biodistribution. Polyurea nanocapsules containing the gadolinium complex Gadobutrol as a contrast agent in high local concentration and high relaxivity up to 40 s-1 mmol-1 L are described. A high concentration of the contrast agent inside the nanocapsules can be ensured by increasing the crystallinity in the shell of the nanocapsules. Nanocapsules from aliphatic polyurea are found to display hi…

BiodistributionPolymers and PlasticsPolymersGadoliniumMRI contrast agentchemistry.chemical_elementContrast MediaBioengineeringGadolinium02 engineering and technology010402 general chemistry01 natural sciencesNanocapsulesGadobutrolBiomaterialschemistry.chemical_compoundCrystallinityMiceNanocapsulesMaterials ChemistrymedicineOrganometallic CompoundsAnimalsHumansTissue DistributionPolyureaMesenchymal Stem CellsDendrites021001 nanoscience & nanotechnologyMagnetic Resonance Imaging0104 chemical scienceschemistryLiverNanocarriers0210 nano-technologySpleenBiotechnologyBiomedical engineeringmedicine.drugMacromolecular bioscience
researchProduct

Comparison of 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine-enhanced MRI in 471 patients with known or suspected renal lesions : results of a mu…

2008

The purpose of this phase III clinical trial was to compare two different extracellular contrast agents, 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine, for magnetic resonance imaging (MRI) in patients with known or suspected focal renal lesions. Using a multicenter, single-blind, interindividual, randomized study design, both contrast agents were compared in a total of 471 patients regarding their diagnostic accuracy, sensitivity, and specificity to correctly classify focal lesions of the kidney. To test for noninferiority the diagnostic accuracy rates for both contrast agents were compared with CT results based on a blinded reading. The average diagnostic accuracy across the three bli…

Gadobutrol; Gadopentate dimeglumine; Renal lesions; MRI; Diagnostic differentiation; NoninferiorityGadolinium DTPAMalemedicine.medical_specialtyContrast MediaRenal lesionsSensitivity and SpecificityGadobutrollaw.inventionGadobutrolPrecontrastRandomized controlled trialmagnetic resonance contrast medialawmedicineOrganometallic CompoundsHumansRadiology Nuclear Medicine and imagingSingle-Blind Methodddc:610Neuroradiologymedicine.diagnostic_testbusiness.industryDiagnostic differentiationUltrasoundReproducibility of ResultsMagnetic resonance imagingInterventional radiologyGeneral MedicineNoninferiorityMiddle AgedImage EnhancementMagnetic Resonance ImagingKidney NeoplasmsClinical trialEuropeRadiology Nuclear Medicine and imagingFemaleGadopentate dimeglumineRadiologybusinessNuclear medicinemedicine.drugMRI
researchProduct

Ergebnisse der kontrastverstärkten MR-Angiographie der aortoiliakalen Gefäße mit einem 1-molaren Kontrastmittel bei 1,0 T: Vergleich zur i. a. DSA

2004

PURPOSE To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) using a 1.0 molar contrast agent at 1.0 T for the diagnosis of abdominal aortic aneurysms and stenoses of renal or iliac arteries in comparison to intraarterial digital subtraction angiography (DSA). MATERIALS AND METHODS A total of 19 patients with the suspicion of abdominal aortic aneurysm or stenosis of renal or iliac arteries were examined with CE-MRA at 1.0 T. Intra-arterial DSA served as reference in all cases. After test bolus tracking, 10 or 8 ml of the 1.0 molar contrast agent Gadobutrol corresponding to a dose of 0.1 - 0.15 mmol/kg bw were injected and imaging performed using a FLASH-3D sequen…

Molarmedicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedia_common.quotation_subjectDigital subtraction angiographymedicine.diseaseAbdominal aortic aneurysmGadobutrolStenosisText miningOcclusioncardiovascular systemmedicineContrast (vision)Radiology Nuclear Medicine and imagingRadiologybusinessmedicine.drugmedia_commonRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Myocardial fibrosis by delayed enhancement cardiovascular magnetic resonance and HCV infection in thalassemia major patients.

2010

Abstract Abstract 4265 Introduction. Delayed enhancement (DE) cardiac magnetic resonance (CMR) technique with intravenous administration of gadolinium (Gd) chelates contrast agents is the only validated non-invasive approach for detecting myocardial fibrosis (Mahrholdt H et al, Eur Heart J 2005). This technique has been confirmed safe in patients with hemoglobinopathies (Meloni A et al, Haematologica 2009). In thalassemia major (TM), myocardial fibrosis has been detected using the DE technique and a positive correlation with anti-HCV antibodies has been described (Pepe A et al, Heart 2009). However, HCV-induced cardiomyopathy is still controversial (Matsumori A et al. J Card Fail 2006). The…

medicine.medical_specialtyHepatitis C virusThalassemiaImmunologyCardiomyopathymedicine.disease_causeBiochemistryGastroenterologyGadobutrolPathogenesisInternal medicineMyocardial fibrosisMedicinemedicine.diagnostic_testbusiness.industryMyocardial fibrosis; HCV infection; Thalassemia MajorRetrospective cohort studyMagnetic resonance imagingCell BiologyHematologymedicine.diseaseSurgeryHCV infectionMyocardial fibrosisbusinessThalassemia Majormedicine.drug
researchProduct