Search results for "Gas analyzer"
showing 10 items of 24 documents
Time-restricted eating effects on performance, immune function, and body composition in elite cyclists: a randomized controlled trial.
2020
Abstract Background Although there is substantial interest in intermittent fasting as a dietary approach in active individuals, information regarding its effects in elite endurance athletes is currently unavailable. The present parallel randomized trial investigated the effects of a particular intermittent fasting approach, called time-restricted eating (TRE), during 4 weeks of high-level endurance training. Methods Sixteen elite under-23 cyclists were randomly assigned either to a TRE group or a control group (ND). The TRE group consumed 100% of its estimated daily energy needs in an 8-h time window (from 10:00 a.m. to 6:00 p.m.) whilst energy intake in the ND group was distributed in 3 me…
Gas Transport in Mixed Matrix Membranes: Two Methods for Time Lag Determination
2020
The most widely used method to measure the transport properties of dense polymeric membranes is the time lag method in a constant volume/pressure increase instrument. Although simple and quick, this method provides only relatively superficial, averaged data of the permeability, diffusivity, and solubility of gas or vapor species in the membrane. The present manuscript discusses a more sophisticated computational method to determine the transport properties on the basis of a fit of the entire permeation curve, including the transient period. The traditional tangent method and the fitting procedure were compared for the transport of six light gases (H2, He, O2, N2, CH4, and CO2) and ethane an…
Ratiocalc: Software for processing data from multicomponent volcanic gas analyzers
2015
Portable gas analyzers have become a powerful tool for the real-time monitoring of volcanic gas composition over the last decade. Gas analyzers make it possible to retrieve in real-time the chemical composition of a fumarole system or a plume in an open-conduit volcano via periodic field-deployments or at permanent stations. The core of a multicomponent volcanic gas analyzer (MultiGAS) consists of spectroscopic and electrochemical sensors that are used to determine the concentrations of the most abundant volcanic gases (H2O, CO2, SO2, H2S, H2, CO and HCl) in a diluted plume and their mutual molar ratios. Processing such data is often difficult due to the high sensitivity of the sensors to e…
Validation of the use of Actigraph GT3X accelerometers to estimate energy expenditure in full time manual wheelchair users with spinal cord injury.
2013
Study design: Cross-sectional validation study. Objectives: The goals of this study were to validate the use of accelerometers by means of multiple linear models (MLMs) to estimate the O2 consumption (VO2) in paraplegic persons and to determine the best placement for accelerometers on the human body. Setting: Non-hospitalized paraplegics’ community. Methods: Twenty participants (age=40.03 years, weight=75.8 kg and height=1.76 m) completed sedentary, propulsion and housework activities for 10 min each. A portable gas analyzer was used to record VO2. Additionally, four accelerometers (placed on the non-dominant chest, non-dominant waist and both wrists) were used to collect second-by-second a…
ODOUR STUDY WITH QUALITATIVE AND QUANTITATIVE RESEARCH METHODS IN VARIOUS DISTRICTS OF RIGA
2017
Different emission sources of odours become increasingly important environmental problem which may have a negative impact on human health and quality of life. Human odour perception may be subjective, however on odour perception threshold is considered to be the odorant concentration where at least half of odour assessor’s group members confirm the existence of odour, and then it is 1 OUE /m3. Nowadays more and more advanced technologies are used to measure odour concentration. Olfactometer Scentroid SM100 allows users to accurately quantify ambient odour concentration in field. Also this equipment allows to collect source samples and analyze odour in a laboratory. Odour study in 2016 and 2…
Gas emissions and crustal deformation from the Krýsuvík high temperature geothermal system, Iceland
2020
Abstract The Krýsuvik volcanic system is located on the oblique spreading Reykjanes Peninsula, SW Iceland. Since early 2009 the region has been undergoing episodes of localized ground uplift and subsidence. From April–November 2013, we operated near-real time monitoring of gas emissions in Krýsuvik, using a Multi-component Gas Analyzer System (Multi-GAS), collecting data on gas composition from a fumarole (H2O, CO2, SO2, H2S). The dataset in this study, comprises a near-continuous gas composition time series, the quantification of diffuse CO2 gas flux, analytical results for direct samples of dry gas, seismic records, and GPS data. Gas emissions from the Krýsuvik geothermal system were exam…
Hill Runner's Physiology, Performance and Nutrition: A Descriptive Study.
2021
Objectives: The aim of this descriptive study was to characterise anthropometric variables, aerobic capacity, running performance and energy intake and expenditure of hill runners in free-living conditions, and to investigate the relationship between age, anthropometric variables, aerobic capacity and running performance.Methods: Twenty-eight hill runners participated in this study (17 males and 11 females; aged 18–65 years). Body fat percentage estimate, sum of eight skinfolds (triceps, subscapular, biceps, iliac crest, supraspinale, abdominal, front thigh and medial calf) and maximal oxygen capacity (VO2max) were assessed in a laboratory setting. Participants also completed a timed hill r…
Excess volatiles supplied by mingling of mafic magma at an andesite arc volcano
2010
We present the results of a study of volcanic gases at Soufriere Hills Volcano, Montserrat, which includes the first spectroscopic measurements of the major gas species CO2 and H2S at this volcano using a Multisensor Gas Analyzer System (MultiGAS) sensor. The fluxes of CO2 and H2S were 640.2750 t/d and 84.266 t/d, respectively, during July 2008, during a prolonged eruptive pause. The flux of CO2 is similar to estimates for the entire arc from previous geochemical studies, while the measured H2S flux significantly alters our interpretation of the sulphur budget for this volcano. The fluxes of both sulphur and carbon show considerable excesses over that which can be supplied by degassing of e…
Chemical mapping of a fumarolic field: La Fossa Crater, Vulcano Island (Aeolian Islands, Italy)
2005
[1] The performance of a newly-developed portable gas analyzer, capable of real-time measurement of CO2, SO2 and H2S concentrations in volcanic gases, was tested at La Fossa Crater, Vulcano Island. The gas analyzer was used to acquire about 3000 determinations over the fumarolic field, allowing the definition of its chemical structure and heterogeneity. Our high-resolution analysis reveals that, in December 2004, the La Fossa fumarolic field was characterized by an oxidized inner core (SO2/H2S ratios of ∼3), and by more reducing conditions on its northern edge (SO2/H2S ratios of ∼1; range: 0.2–3.3). CO2/(SO2+H2S) molar ratios averaged 35 ± 21, with overlapping compositions for rim and inner…
A new approach for the measurement of gaseous elemental mercury (GEM) and H2S in air from anthropogenic and natural sources: Examples from Mt. Amiata…
2017
Real-time measurements of GEM and H2S discharged from natural and anthropogenic sources are a valuable tool to investigate the dispersion dynamics of these contaminants in air. In this study, a new approach to measure GEM and H2S concentrations in air, carried out by coupling a portable Zeeman atomic absorption spectrometer with high frequency modulation of light polarization (Lumex RA-915M) and a pulsed fluorescence gas analyzer (Thermo Scientific Model 450i), was applied to two distinct areas: (i) in the surroundings of Piancastagnaio (Siena, Central Italy), located in the eastern flanks of Mt. Amiata (a 200,000Â years old volcano), where three geothermal plants are operating and whose ex…