Search results for "Gas detector"
showing 10 items of 30 documents
A cylindrical GEM detector with analog readout for the BESIII experiment
2016
Abstract A cylindrical GEM detector with analog readout is under development for the upgrade of the Inner Tracker of the BESIII experiment at IHEP (Beijing). The new detector will match the requirements for momentum resolution ( σ pt / p t ~ 0.5 % at 1 GeV) and radial resolution ( σ xy ~ 120 μ m ) of the existing drift chamber and will improve significantly the spatial resolution along the beam direction ( σ z ~ 150 μ m ) with very small material budget (less than 1.5% of X 0 ). With respect to the state of the art the following innovations will be deployed: a lighter mechanical structure based on Rohacell, a new XV anode readout plane with jagged strip layout to reduce the parasitic capaci…
Design, Construction and Performance Tests of a Prototype MicroMegas Chamber with Two Readout Planes in a Common Gas Volume
2016
In this paper, the design and the performance of a prototype detector based on MicroMegas technology with two detection planes in a common gas volume is discussed. The detector is suited for the forward region of LHC detectors, addressing the high-rate environment and limited available space. Each detection plane has an active area of 9x9 cm^2 with a two-dimensional strip readout and is separated by a common gas region with a height of 14 mm. A micro-mesh, working as a cathode, is placed in the middle of the common gas volume separating it into two individual cells. This setup allows for an angle reconstruction of incoming particles with a precision of 2 mrad. Since this design reduces the …
Signal Characteristics of a Resistive-Strip Micromegas Detector with an Integrated Two-Dimensional Readout
2014
In recent years, micropattern gaseous detectors, which comprise a two-dimensional readout structure within one PCB layer, received significant attention in the development of precision and cost-effective tracking detectors in medium and high energy physics experiments. In this article, we present for the first time a systematic performance study of the signal characteristics of a resistive strip micromegas detector with a two-dimensional readout, based on test-beam and X-ray measurements. In particular, comparisons of the response of the two independent readout-layers regarding their signal shapes and signal reconstruction efficiencies are discussed.
Layout and performance of RPC used in the Argo-YBJ experiment
2006
The layout of the RPCs, used in the Argo-YBJ experiment to image with a high space-time granularity the atmospheric shower, is described in this paper. The detector has been assembled to provide both digital and analog informations in order to cover a wide particle density range with a time accuracy of 1 ns. The experimental results obtained operating the chambers in streamer mode at sea level with a standard gas mixture are presented. (c) 2006 Elsevier B.V. All rights reserved.
Resistive Micromegas for the Muon Spectrometer Upgrade of the ATLAS Experiment
2017
It is reported on the construction and test of large scale resistive Micromegas detectors for the ATLAS New Small Wheel upgrade. The production procedure of the 2 to 3 m2 active area is described. The validation of the construction procedure is proven with results obtained with prototype detectors showing 100 µm spatial resolution in the precision coordinate and above 98% efficiency In the context of the upgrade project of the ATLAS Muon system, we report on the construction of Micromegas detectors with an active area of 2 to 3 m$^2$ . The validation of the construction procedure is proven with results obtained with prototype detectors showing 100 $\mu $m spatial resolution in the precision…
Chromatographic Air Analyzer Microsystem for the Selective and Sensitive Detection of Explosive-related Compounds
2014
Abstract The detection of explosives and explosive-related compounds is of major importance for the monitoring of explosive- contaminated sites. Current methods need to become cheaper and portable while maintaining a high sensitivity and selectivity level. In that sense, a silicon micro-analytical platform consisting of a three-dimensional micro-preconcentrator based on a hydrophobic zeolite, coupled to a silicon spiral micro-column was built. A chemical gas sensor acted as a miniaturized gas detector. This system allowed selective detection of orthonitrotoluene (ONT), an explosive-related compound at the sub-ppm level in the presence of toluene and moisture.
Detection of lung cancer bio-markers in human breath using a micro-fabricated air analyzer
2015
International audience; The analysis of volatile organic compounds (VOCs) that are linked to lung cancer is a very promising way in medical diagnostics because it is non-invasive and potentially inexpensive. In that sense, a silicon micro-analytical platform consisting of a three-dimensional micro-preconcentrator coupled to a silicon spiral gas chromatographic micro-column was built. A metal oxide-based gas sensor acted as a miniaturized gas detector. This system allowed selective detection of VOCs at the sub-ppm level. The present study is focused first on the chromatographic air analyzer fabrication and second on the selection of an appropriate adsorbent. Various adsorbents such as activa…
Large bulk Micromegas detectors for TPC applications
2009
A large volume TPC will be used in the near future in a variety of experiments including T2K. The bulk Micromegas detector for this TPC is built using a novel production technique particularly suited for compact, thin and robust low mass detectors. The capability to pave a large Surface with a simple mounting Solution and small dead space is of particular interest for these applications. We have built several large bulk Micromegas detectors (36 x 34 cm(2)) and we have tested one in the former HARP field cage with a magnetic field. Prototypes cards of the T2K front end electronics, based on the AFTER ASIC chip, have been used in this TPC test for the first time. Cosmic ray data have been acq…
Development of a thermodesorption sensor system for the detection of residual solvents in packaging materials
2004
Application specific sensor systems (formerly electronic noses) use static headspace for the volatile generation from condensed phase samples. This extraction method is very simple to implement, but suffers many drawbacks, i.e. in terms of efficiency or sensitivity to partitioning and is very time-consuming. To circumvent these problems, we developed a new method using dynamic extraction of volatiles (stripping). Although this method is known for GC (gas chromatography), the utilization of direct thermal desorption (DTD) in conjunction with gas sensors is quite novel. The unhandy cold trapping step can be avoided by a software integration of the instantaneous volatile concentration over the…
The NEXT experiment for neutrinoless double beta decay searches
2015
211 páginas. Tesis Doctoral del Departamento de Física Atómica, Molecular y Nuclear, de la Universidad de Valencia y del Instituto de Física Corpuscular (IFIC).