Search results for "Gel permeation chromatography"

showing 10 items of 115 documents

1981

The dynamical region of the measured calibration curves is investigated using the results of the theory published previously. The kinetic constants of the flow-equilibrium are calculated from the measurements according to two different models for a spontaneous polymer diffusion of the transported P-mer from sol into gel of the Phase Distribution Chromatography (PDC)-column. The corresponding lateral concentration profiles in the gel are found by analytical integration of Fick's second law under the corresponding boundaries. An energetic model of this flow-equilibrium is stated, giving the activation enthalpy and -entropy of the rediffusion of the polymer from gel into sol after some retarda…

Condensed Matter::Soft Condensed MatterGel permeation chromatographychemistry.chemical_classificationChromatographyChemistryElutionCalibration curveEnthalpyAnalytical chemistryMolar mass distributionPolymerKinetic energyDie Makromolekulare Chemie
researchProduct

Determination of PAHs in airborne particles by accelerated solvent extraction and large-volume injection-gas chromatography-mass spectrometry.

2006

Abstract A sensitive and automated method is presented for the determination of polycyclic aromatic hydrocarbons (PAHs) in airborne particulate matter. The procedure includes extraction of PM10-bound PAHs by accelerated solvent extraction (ASE) followed by gel permeation chromatography (GPC) clean-up, and large-volume programmable temperature vaporizer (PTV–LV) injection coupled to GC–MS. The limit of detection (LOD) of the whole method, based on a signal-to-noise ratio (S/N) of 3:1, ranged from 0.26 pg m−3 to 3 pg m−3 when air volumes of 760 m3 are collected. The hexane–acetone mixture (1:1, v/v) gave the best recoveries when ASE parameters were fixed at 125 °C, 1500 psi, and a total time …

Detection limitChromatographyCentral composite designChemistryExtraction (chemistry)Analytical chemistryAnalytical ChemistryGel permeation chromatographymedia_common.cataloged_instanceSample preparationGas chromatographyGas chromatography–mass spectrometryEuropean unionmedia_common
researchProduct

A rapid and reliable size-exclusion chromatographic method for determination of kojic dipalmitate in skin-whitening cosmetic products

2007

A size-exclusion chromatographic method has been developed to determine the relatively novel skin-whitening agent called kojic dipalmitate (KDP) in skin-whitening cosmetic products. Preliminary experiments were carried out in order to select the solvent for standard and sample solution, and also for mobile phase composition. A PLGel Mixed-D (polystyrene/divinylbenzene co-polymer) column and isocratic mobile phase of pure tetrahydrofuran (at 1.5 mL min(-1) flow rate) were used. Detection was carried out by means of an UV/vis spectrometry detector set at 248 nm. A study of interferences reveals that KDP can be determined without interferences coming from cosmetic matrices. Most other cosmetic…

Detection limitChromatographymedicine.diagnostic_testSize-exclusion chromatographyReproducibility of ResultsSkin PigmentationSkin whiteningCosmeticsDivinylbenzeneSensitivity and SpecificityAnalytical ChemistrySolventGel permeation chromatographychemistry.chemical_compoundchemistryPyronesSpectrophotometryChromatography GelmedicineSpectrophotometry UltravioletCosmetic industryTalanta
researchProduct

Contributions to the analysis of organic xenobiotics in fish

1995

For the residue-analysis of fish samples, a method has been developed to separate the medium polar triazines and acetamides together with lipophilic xenobiotics (organochlorine pesticides, PCBs and octachlorostyrene) from fish tissue. The detection limits of the analytes are mostly within the ppt-range (ng/kg fillet) and vary between 40 and 1050 ng/kg fillet of fish. Their recoveries range from 75 to 108%, spiked at 1.5 μg/kg. The substances are extracted with a mixture of petroleum ether/ethylacetate (2:1) using a soxhlet apparatus. Subsequently, the lipids in the sample extracts are reduced to 0.4% by gel chromatography. A 5 g silica gel clean-up separates the analytes according to their …

Detection limitGel permeation chromatographychemistry.chemical_compoundChlorophenoxy herbicideChromatographyChemistryElutionSilica gelPetroleum etherGas chromatography–mass spectrometryBiochemistryAcetamideAnalytical ChemistryFresenius' Journal of Analytical Chemistry
researchProduct

Development of a method for the analysis of seven banned azo-dyes in chilli and hot chilli food samples by pressurised liquid extraction and liquid c…

2008

An automated, confirmatory and sensitive procedure has been developed and validated for the determination of Sudan (I-IV), Sudan Orange G, Sudan Red 7B and Para Red in hot chilli food samples. The proposed method includes pressurised liquid extraction (PLE) with acetone, gel permeation chromatography (GPC) clean-up and detection by liquid chromatography (LC) coupled to electrospray ionization in positive mode tandem mass spectrometry (ESI-MS-MS). The main parameters affecting the performance of the different ionization sources and PLE parameters were previously optimised using statistical design of experiments (DOE). The method was in-house validated on chilli powder and chilli meat. Linear…

Detection limitSpectrometry Mass Electrospray IonizationChemical ionizationElectrosprayChromatographyChemistryElectrospray ionizationFood Coloring AgentsFood ContaminationSudan Red 7BMass spectrometryAnalytical ChemistryGel permeation chromatographychemistry.chemical_compoundMethodsPara RedCapsicumAzo CompoundsFood AnalysisChromatography LiquidTalanta
researchProduct

On-line gel permeation chromatography–attenuated total reflectance–Fourier transform infrared determination of lecithin and soybean oil in dietary su…

2007

Gel permeation chromatography (GPC) with attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectrometry detection has been proposed for the simultaneous determination of lecithin and soybean oil in dietary supplements. The method involves the extraction of analytes with dichloromethane in an ultrasound water bath and the injection of 2 ml of centrifuged and filtered extracts into the system integrated by two Envirogel GPC columns (19 mm x150 mm, 19 mm x 300 mm) coupled on-line. Dichloromethane was used as mobile phase. A method has been developed to select the most appropriated wavenumber to be used for the determination of each considered compound from the calculation of a…

Detection limitfood.ingredientChromatographyFourier AnalysisChemistrySpectrum AnalysisOrganic ChemistryGeneral MedicineBiochemistryLecithinSoybean oilSoybean OilAnalytical ChemistryGel permeation chromatographyVegetable oilfoodLinear rangeAttenuated total reflectionDietary SupplementsLecithinsSpectroscopy Fourier Transform InfraredChromatography GelSoybeansFourier transform infrared spectroscopyJournal of Chromatography A
researchProduct

Polymerization of methyl methacrylate through ionizing radiation in CO2-based dense systems

2000

Herein, we report the use of ionizing radiation to induce a dispersion polymerization reaction in dense CO2. As a model system, the polymerization of methyl methacrylate in the presence of poly(dimethylsiloxane) stabilizers was investigated. It was demonstrated that the dose plays the key role in the progress of the reaction and in the morphology of the resulting polymer. Dispersion polymerization carried out in the presence of mono- and bifunctionalized surfactants gave differently structured polymers. The polymers obtained have been characterized by scanning electron microscopy, solubility tests, and gel permeation chromatography, and the molecular structure has been related to dynamic me…

Dispersion polymerizationchemistry.chemical_classificationPolymers and PlasticsOrganic ChemistryPolymerInorganic ChemistryGel permeation chromatographychemistry.chemical_compoundChain-growth polymerizationchemistryPolymerizationChemical engineeringPolymer chemistrySupercritical fluids polymersMaterials ChemistrySolubilityMethyl methacrylateIonic polymerization
researchProduct

1988

Synthese par alkylation reductrice de l'anthracene par des electrophiles bifonctionnels comme le dibromo-1,3 propane. Le polymere du titre est un precurseur du polymere redox polyanthrylenetrimethylene

Gel permeation chromatographyAnthracenechemistry.chemical_compoundChain structureReaction mechanismchemistryMolar mass distributionOrganic chemistryAlkylationCharacterization (materials science)Die Makromolekulare Chemie, Rapid Communications
researchProduct

Molekulargewichtsverteilungen bei der rein thermischen Substanzpolymerisation von Styrol

1972

An rein thermisch in Substanz polymerisiertem Styrol wurden an Testfraktionen mittels kombinierter Gelchromatographie und Viskosimetrie die Molekulargewichte bestimmt. Dabei erhalt man die absoluten Molekulargewichte unabhangig von einer in den Praparaten auftretenden Verzweigung. Die Verteilungen selbst wurden gelchromatographisch gemessen. Fur die Breite der Molekulargewichtsverteilungen ergeben sich im Mittel Mw/Mn-Werte von 2,2. Dies entspricht einer Uneinheitlichkeit U = 1,2, die also etwas groser ist, als bei einer ScHuLzverteilung mit Kopplungsgrad 1. Der hohere U-Wert last sich durch die Nichtstationaritat des realen Polymerisationsvorganges und den Verzweigungsmechanismus erklaren.…

Gel permeation chromatographyChemistryPolymer chemistryAnalytical chemistryGeneral Materials ScienceAngewandte Makromolekulare Chemie
researchProduct

Strukturuntersuchung von polyestern durch direkten abbau im massenspektrometer, 3. Poly-β-propiolacton, poly-β-pivalolacton und poly-δ-valerolacton

1978

Poly(oxycarbonylethylene) (poly-β-propiolactone), poly(oxycarbonyl-1,1-dimeothylethylene) (poly-β-pivalolactone), and poly(oxycarbonyltetramethylene) (poly-δ-valerolactone) were pyrolyzed directly in the ion source of a mass spectrometer and their thermal and electron impact induced degradation mechanisms are established. Poly-β-propiolactone is thermally degraded by rupture of the OCH2-bond by a cis elimination to give carboxyl and acryloyl endgroups, whereas poly-δ-valerolactone depolymerizes to δ-valerolactone. Poly-β-pivalolactone degrades thermally to cyclic oligomers of pivalolactone, which could be proved by a separated pyrolysis and IR-spectroscopy and gel chromatography.

Gel permeation chromatographyChemistryPolymer chemistryDegradation (geology)Mass spectrometryPyrolysisElectron ionizationIon sourceDie Makromolekulare Chemie
researchProduct