Search results for "Genetic Structures"

showing 10 items of 2107 documents

Fixed Mydriatic Pupil Associated with an Intraocular Pressure Rise as a Complication of the Implant of a Phakic Refractive Lens (PRL)

2013

We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in o…

AdultPhakic Intraocular Lensesmedicine.medical_specialtygenetic structuresVisual AcuityVisual DiscomfortSuctionPhakic intraocular lensPhakic intraocular lensIris atrophyLens Implantation IntraocularOphthalmologyMyopiamedicineMydriasisHumansAntihypertensive AgentsIntraocular PressureÓpticabusiness.industryMydriasisGlare (vision)General MedicineRefractive lensCombined Modality Therapyeye diseasesOphthalmologymedicine.anatomical_structureSecondary glaucomaLens (anatomy)OptometryFemaleOcular Hypertensionsense organsImplantmedicine.symptomComplicationbusinessUrrets-Zavalia syndromeSeminars in Ophthalmology
researchProduct

Effect of Color on Contrast Sensitivity with Two Different Accommodative Stimuli

1993

We studied the influence of color and accommodation on the contrast sensitivity function (CSF). At the same time, we measured the effect of axial chromatic aberration (ACA) on the CSF. The CSF's of two observers were determined using red, green, blue, and white light, at 5- and 0.5-m viewing distances. At 5 m the CSF's were measured with natural vision and also with lenses which compensated the ACA. Results show that the effect of ACA on the CSF is to reduce the sensitivity to blue with respect to the red. The difference in sensitivity between these two colors is between 50 and 150% and varies with the frequency and the subject. When the ACA is compensated the influence of the color on the …

AdultPhysicsmedicine.medical_specialtyLightgenetic structuresbusiness.industryColour VisionAccommodation OcularStimulus (physiology)eye diseasesContrast SensitivityOphthalmologyNear visionOpticsSpectral sensitivityChromatic adaptationOphthalmologyChromatic aberrationmedicineWhite lightHumansSensitivity (control systems)businessColor PerceptionOptometryOptometry and Vision Science
researchProduct

Visual Acuity in Simple Myopic Astigmatism: Influence of Cylinder Axis

2006

Purpose. The relationship between astigmatic refractive errors and their associated visual acuity has been studied in recent years in the context of refractive power space. The influence of the axis of astigmatism remains a matter of controversy. Our goal in this study is to provide additional experimental evidence to clarify this subject. The influence of the simulated axis orientation was compared with other factors that affect visual acuity such as the particular design of the test and the differences between eyes. Methods. Simple myopic astigmatism from 0 to 3.00 D, in steps of 0.25 D, and with five different axes between 0° and 90°, were simulated on four healthy eyes of young observer…

AdultRefractive errorVisual acuitygenetic structuresOrientation (computer vision)Visual AcuityAstigmatismContext (language use)Optical powerAstigmatismPrognosisRefraction Ocularmedicine.diseaseSubjective refractioneye diseasesVision disorderOphthalmologyMyopiamedicineHumansOptometrymedicine.symptomOptometryMathematicsOptometry and Vision Science
researchProduct

Impact of the line of sight on toric phakic intraocular lenses for hyperopia

2003

We present a hyperopic patient with a decentered line of sight in whom the residual refractive error after toric phakic intraocular lens (TP IOL) implantation was improved by displacement and individualized treatment. A 35-year-old woman presented with asthenopic complaints 2 months after bilateral TP IOL implantation and IOL rotation 4 weeks later. Examination revealed the line of sight to be nasally and inferiorly decentered in relation to the center of the pupil. A more nasal reenclavation of the TP IOL decreased the coma, and the uncorrected visual acuity was 20/20. We conclude that line of sight should be measured before TP IOL implantation, especially in hyperopic eyes.

AdultReoperationRefractive errormedicine.medical_specialtygenetic structuresEye diseasemedicine.medical_treatmentVision DisordersVisual AcuityComa (optics)Intraocular lensUncorrected visual acuityPhakic intraocular lensPupilVision disorderForeign-Body MigrationLens Implantation IntraocularOphthalmologyLens CrystallinemedicineHumansbusiness.industryAstigmatismCorneal TopographyPupilmedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaOptometryFemaleSurgeryAsthenopiasense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Blue-yellow deficiencies in young moderate smokers.

2021

Purpose To evaluate whether tobacco affects color vision in young moderate smokers. Methods Chromatic mechanisms of 13 moderate smokers (10–20 cigarettes/day and at least 5 years smoking) and 17 non-smokers in the 18–35 age range were assessed with the Farnsworth-Munsell 100-hue (FM100h) test and short wavelength automated perimetry (SWAP). Results FM100h Total Error Scores (TES) were higher for smokers, and although differences were not significant (p = 0.14), a linear model with principal component analysis was able to explain 95% of the variance in TES and red-green partial error scores, though not in blue-yellow partial error scores (p = 0.07), using the number of years as smokers and t…

AdultRetinal Ganglion Cellsmedicine.medical_specialtygenetic structuresAdolescentColor visionPilot ProjectsAudiologySensitivity lossRetinal ganglionTotal errorYoung smokers03 medical and health sciencesYoung Adult0302 clinical medicineShort wavelength automated perimetryMedicineHumansDifference mapSmokersColour visionbusiness.industryColour VisionBlue/yellow perimetry030221 ophthalmology & optometryLinear ModelsVisual Field TestsBlue-yellow perimetryOriginal Articlebusiness030217 neurology & neurosurgeryColor PerceptionOptometryJournal of optometry
researchProduct

Optical Coherence Tomography Angiography of Optic Disc in Eyes With Primary Open-angle Glaucoma and Normal-tension Glaucoma.

2019

PURPOSE To examine vessel density (VD) properties of the optic nerve head in eyes with ocular hypertension (OHT), high-tension glaucoma (HTG), and normal-tension glaucoma (NTG) and to evaluate associations on structural parameters of retinal nerve fiber layer (RNFL). METHODS Three groups of patients with OHT (n=15), HTG (n=36), and NTG (n=22), and a healthy control group (n=23) were included in this study. Peripapillary VD and optic disc flow area were measured using optical coherence tomography angiography, and peripapillary RNFL (pRNFL) thickness was determined. Global and sectoral analysis of optic nerve head vasculature and pRNFL thickness were measured. RESULTS Glaucomatous eyes had lo…

AdultRetinal Ganglion Cellsmedicine.medical_specialtygenetic structuresOpen angle glaucomaOptic DiskNerve fiber layerOcular hypertensionGlaucoma03 medical and health sciences0302 clinical medicineNerve FibersNormal tension glaucomaOphthalmologymedicineHumansLow Tension GlaucomaFluorescein AngiographyIntraocular PressureAgedRetrospective StudiesAged 80 and overmedicine.diagnostic_testbusiness.industryRetinal VesselsMiddle Agedmedicine.diseaseFluorescein angiographyeye diseasesOphthalmologymedicine.anatomical_structureCross-Sectional Studies030221 ophthalmology & optometryOptic nerveFemaleOcular Hypertensionsense organsVisual Fieldsbusiness030217 neurology & neurosurgeryGlaucoma Open-AngleTomography Optical CoherenceOptic discJournal of glaucoma
researchProduct

Avaliação da resposta de acomodação após tarefas visuais próximas usando diferentes dispositivos eletrônicos portáteis

2015

ABSTRACT Purpose: To assess the accommodation response after short reading periods using a tablet and a smartphone as well as determine potential differences in the accommodation response at various stimulus vergences using a Hartmann- Shack aberrometer. Methods: Eighteen healthy subjects with astigmatism of less than 1 D, corrected visual acuity of 20/20 or better, and normal findings in an ophthalmic examination were enrolled. Accommodation responses were obtained under three different conditions: accommodation system of the eye relaxed and visually stressed with a tablet and an smartphone for 10 min, at a distance of 0.25 m from the subject's eyes. Three measurements of accommodation res…

AdultVisual acuityCorneal Wavefront AberrationSmartphone/utilizaçãogenetic structuresVisual AcuityComputadores de mão/utilizaçãoStimulus (physiology)Refraction Ocular01 natural sciencesNear visual acuity010309 optics03 medical and health sciences0302 clinical medicinelcsh:Ophthalmology0103 physical sciencesAberrometrymedicineHumansWavefrontbusiness.industryAberrometryComputadores/utilizaçãoGeneral MedicineAmplitude of accommodationOphthalmologySpherical aberrationAcomodação ocularlcsh:RE1-994Accommodation ocular030221 ophthalmology & optometryOptometrySmartphonemedicine.symptombusinessPsychologyAccommodationCell PhoneComputers handheld
researchProduct

Retinal myelinated nerve fibers associated with macular pseudohole

2008

We report the case of a 24-year-old woman who presented unilateral extensive peripapillary myelinated nerve fibers associated with macular pseudohole and bilateral low myopia. Visual acuity, slit lamp biomicroscopy, automated perimetry, fundus color photography, and optical coherence tomography (Stratus® OCT) were performed. We discuss the clinical findings and diagnostic details of unilateral extensive peripapillary myelinated nerve fibers associated with macular pseudohole.

AdultVisual acuitygenetic structuresMyelinated nerve fiberNerve fiberEpiretinal membrane Macular pseudohole Oligodendrocytes Retinal myelinated nerve fibersFundus (eye)Nerve Fibers MyelinatedRetinal DiseasesmedicineHumansMacula LuteaFluorescein AngiographyMacular holebusiness.industrySettore MED/30 - Malattie Apparato VisivoOptic NerveAnatomymedicine.diseaseeye diseasesOphthalmologymedicine.anatomical_structureOptic nerveMaculopathyFemalesense organsEpiretinal membranemedicine.symptombusiness
researchProduct

Quantitative corneal anatomy in emmetropic subjects.

2006

PURPOSE Currently there is little information available about the corneal thickness values of healthy emmetropic subjects. Therefore, the authors decided to analyze the corneal thickness in healthy emmetropic subjects. METHODS The authors analyzed the difference in thickness values between the thinnest corneal site and the central and paracentral cornea in 124 eyes of 124 healthy emmetropic white subjects. RESULTS The mean difference between the thinnest site of the cornea and the thickness values obtained in the areas analyzed was as follows: 12+/-6 microm center; 140+/-19 microm superonasal; 133+/-23 microm nasal; 117+/-26 microm inferonasal; 122+/-19 microm superotemporal ; 89+/-22 micro…

Adultgenetic structuresAdolescentEmmetropiaMean differenceCornea03 medical and health sciences0302 clinical medicineReference ValuesCorneamedicineHumansProspective StudiesUltrasonographyObserver VariationAnthropometrybusiness.industryGeneral MedicineAnatomyeye diseasesOphthalmologymedicine.anatomical_structureReference values030221 ophthalmology & optometrysense organsUltrasonographyObserver variationbusiness030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

Monocular versus binocular pupillometry.

2004

Purpose To quantify differences between monocular and binocular pupil size measurement under scotopic and mesopic conditions. Setting Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany. Methods Computerized dynamic pupillometry (P2000 SA, Procyon Instruments Ltd.) was used at 3 illumination levels: scotopic at 0.03 lux, mesopic low at 0.82 lux, and mesopic high at 6.4 lux. One hundred forty eyes of 70 healthy volunteers without ocular pathology were examined. The subjects were divided into 2 groups. In the first group, the pupil diameter was measured binocularly first. In the secon…

Adultgenetic structuresAdolescentMesopic visionmedicine.medical_treatmentDark AdaptationDiagnostic Techniques OphthalmologicalVision MonocularStatistical significanceRefractive surgeryMedicineHumansScotopic visionVision BinocularMonocularbusiness.industryPupileye diseasesSensory SystemsOphthalmologyQuartileOptometrySurgerysense organsbusinessBinocular visionPupillometryJournal of cataract and refractive surgery
researchProduct