Search results for "Geometry"
showing 10 items of 4487 documents
On multivalued weakly Picard operators in partial Hausdorff metric spaces
2015
We discuss multivalued weakly Picard operators on partial Hausdorff metric spaces. First, we obtain Kikkawa-Suzuki type fixed point theorems for a new type of generalized contractive conditions. Then, we prove data dependence of a fixed points set theorem. Finally, we present sufficient conditions for well-posedness of a fixed point problem. Our results generalize, complement and extend classical theorems in metric and partial metric spaces.
Constant Power Model in Arm Rotation—A New Approach to Hill’s Equation
2014
The purpose of this study was to further develop the constant power model of a previous study and to provide the final solution of Hill’s force-velocity equation. Forearm and whole arm rotations of three different subjects were performed downwards (elbow and shoulder extension) and upwards (elbow and shoulder flexion) with maximum velocity. These arm rotations were recorded with a special camera system and the theoretically derived model of constant maximum power was fitted to the experimentally measured data. The moment of inertia of the arm sectors was calculated using immersion technique for determining accurate values of friction coefficients of elbow and whole arm rotations. The experi…
Effect of lumbar disc replacement on the height of the disc space and the geometry of the facet joints: a cadaver study.
2010
In a study on ten fresh human cadavers we examined the change in the height of the intervertebral disc space, the angle of lordosis and the geometry of the facet joints after insertion of intervertebral total disc replacements. SB III Charité prostheses were inserted at L3-4, L4-5, and L5-S1. The changes studied were measured using computer navigation sofware applied to CT scans before and after instrumentation. After disc replacement the mean lumbar disc height was doubled (p < 0.001). The mean angle of lordosis and the facet joint space increased by a statistically significant extent (p < 0.005 and p = 0.006, respectively). By contrast, the mean facet joint overlap was significantl…
Redesign of a Reverse Shoulder Prosthesis: Kinematic and Mechanical Study
2014
In this work a commercial reverse shoulder prosthesis has been redesigned to improve performances in terms of range of movements of the implant and stability to dislocation. A kinematic and mechanic study has been performed using a realistic solid model of the prothesised shoulder: in particular, all the components of the prosthesis have been acquired via a 3D laser scanner and inserted in a virtual humerus-glenoid system by reproducing the common surgical procedure. The final model has been used to measure the maximum angles of abduction and rotation of the arm and the shear forces that cause dislocation. Modifications proposed to the commercial prosthesis are: a different orientation of t…
Biomechanical testing of different posterior fusion devices on lumbar spinal range of motion.
2019
Abstract Background Recent minimal-invasive posterior fusion devices are supposed to provide stability and obtain fusion in combination with interbody cages in the instrumented segment. The aim of the present study is to evaluate the primary stability of two minimal-invasive posterior prototypes compared to an established spinous process plate and standard pedicle screw instrumentation. Methods Seven fresh frozen human cadaver lumbar spines (L2–L5) were tested in a spinal testing device with a moment of 7.5 Nm. Spinal stability was determined as mean range of motion (RoM) in the segment L3/L4 during extension-flexion, lateral bending and axial rotation. The RoM was measured during five cond…
Stellenwert der MR-Tomographie bei traumatischen Patellaluxationen
1995
PURPOSE To describe the MR imaging findings in patients with lateral patellar dislocation. MATERIAL AND METHODS The MRIs of 31 patients with patellar dislocation were evaluated retrospectively. Arthroscopic surgery was performed in 23 cases. RESULTS Hemarthrosis was found in 30/31, contusions of the lateral femoral condyle in 30/31 and of the medial patellar facet in 26/31 cases. Injury of the medial patellar retinaculum was seen in 28/31 cases. Osteochondral fractures were found in 18 patients; compared to arthroscopy there were one false-positive and 5 false-negative findings concerning loose cartilage bodies. In 7 cases, patellar dislocation was not suspected before MR imaging. CONCLUSIO…
Case series of fluoroscopic findings and 3D reconstruction of human spinal MRIs of the space of Okada.
2020
Objective To better understand the unexpected spread of contrast medium observed by conventional fluoroscopic X-ray images during standard neuraxial techniques used in the treatment of pain. The support of 3D reconstruction of MRI images of structures within the lumbar spine was used to better understand the space of Okada. Methods Lumbar facet joint and epidural corticosteroid injections in five patients under fluoroscopic guidance with loss of resistance to air or saline to identify the facet joints or epidural space. Next, in a retrospective study, the authors examined the retrodural space of Okada and the neighboring tissues with 3D reconstruction of spinal MRIs of seven patients withou…
Comparison of frictional resistance between passive self-ligating brackets and slide-type low-friction ligature brackets during the alignment and lev…
2019
Background To compare the frictional resistance between passive self-ligating brackets and conventional brackets with low-friction ligature under bracket/archwire and root/bone interface during dental alignment and leveling. Material and methods A tridimensional model of the maxilla and teeth of a patient treated with conventional brackets, and slide ligatures was generated employing the SolidWorks modeling software. SmartClip self-ligating brackets and Logic Line conventional brackets were assembled with slide low-friction ligatures, utilizing archwires with different diameters and alloys used for the alignment and leveling stage. Friction caused during the bracket/archwire interface and s…
A reanalysis of spinal motion during vibration
1987
Calibrated film of the motion of the lumbar spine during vibration was reanalysed, making use of a number of computer based techniques to improve accuracy and reduce measurement noise. The results demonstrated resonant behaviour at about 4 Hz and indicated that at vibration levels of the order of 1 m/s2 there exists bending of the order of 1° (peak to peak) between adjacent vertebrae in the lumbar spine. The bending is complex and involves phase differences along the spine and possibly a rocking motion of the pelvis.
Impaired geometric properties of tibia in older women with hip fracture history.
2007
This study evaluated side-to-side differences in tibial mineral mass and geometry in women with previous hip fracture sustained on average 3.5 years earlier. Both tibial mineral mass and geometry were found to be reduced in the fractured leg. INTRODUCTION: The purpose of this study was to evaluate side-to-side differences in tibial mineral mass and geometry after hip fracture and to assess the determinants of such differences. METHODS: Thirty-eight 60- to 85-year-old women with a previous hip fracture and 22 same-aged control women without fractures participated in the study. Bone characteristics of the distal tibia and tibial shaft of both legs were assessed using pQCT in order to compare …